Imported Connector Verification
ED32BGFBK
- Source file:
ED32BGFBK.elibz
- Imported project: /kproc/ed32bgfbk
- Part UID:
63e570f9-6b31-4efa-8903-7a82ab48a548
- Manufacturer: WingTAT
- MPN: ED32BGFBK
- Designator prefix: J
Verification Result
- Published as part: yes.
- Schematic components: 0.
- Nets: 0.
- PCB layout nodes: 1.
- Conclusion: import is footprint-only. It currently has no schematic terminals, so it cannot be wired into the distribution-board schematic.
Repair Attempt Result
A repair thread was started in the part project, but it reported that available tools could not add schematic terminals/symbols to the footprint-only imported part. The part still has 0 schematic terminals.
Required Repair
Use the Flux part editor or an importable EDA library that includes both symbol and footprint. Add a schematic symbol with 32 terminals and map those terminals to the footprint pads. Use the pin allocation in edge-connector-pinout-rev-a-daughterboard-slot unless the imported footprint numbering proves a different physical order.
DC-S007B-D025-15A
- Source file:
DC-S007B-D025-15A.elibz
- Imported project: /kproc/dc-s007b-d025-15a
- Part UID:
76dfedca-adc2-4fc1-b509-603f002c2698
- Manufacturer: G-Switch
- MPN: DC-S007B-D025-15A
- Designator prefix: J
Verification Result
- Published as part: yes.
- Schematic components: 0.
- Nets: 0.
- PCB layout nodes: 1.
- Conclusion: import is footprint-only. It currently has no schematic terminals, so it cannot be wired into the daughterboard output schematic.
Repair Attempt Result
A repair thread was started but did not complete in a reasonable time and the part still shows 0 schematic terminals. The thread was stopped to avoid indefinite execution.
Required Repair
Use the Flux part editor or an importable EDA library that includes both symbol and footprint. Add a schematic symbol with the connector's real electrical terminals from the datasheet/footprint. Minimum expected terminals are likely center positive, sleeve/ground, and any switched/contact-detect pins if present. Do not assume pinout until the footprint/datasheet is verified.
Current Schematic Impact
Neither imported connector has been added to the active schematic because footprint-only parts would create unusable/no-terminal schematic instances. Once repaired, add:
- 12× ED32BGFBK to the distribution board slot interface.
- 1× DC-S007B-D025-15A per daughterboard output.