PCB Net Routing Completion
J_DWIN sang connector FFC/FPC 10 pin pitch 1.0 mm. Trước tiên mình lưu lại toàn bộ kết nối pin hiện tại, tìm đúng linh kiện 1.0 mm trong thư viện, thay component rồi nối lại đúng 10 chân và kiểm tra lại.J_DWIN vì phiên làm việc đã hết credit ngay sau khi bắt đầu bước thay linh kiện.J_DWIN hiện tại là FFC2B35-10-G, 10 pin, pitch 0.5 mm.J_DWIN.J_DWIN cũ bằng connector 1.0 mm.Table
| # | Component | Override target | Rule/property overridden | Classification | Action | Reason |
|---|---|---|---|---|---|---|
| 1 | D_RS485 | REF text shape | position = -6.4194 mm 3.4435 mm; active = false | SAFE_KEEP | Kept | Silkscreen reference text visibility/position; no routing/footprint effect, but likely intentional label cleanup. |
| 2 | D101 | REF text shape | position = 5.9065 mm -0.2595 mm | SAFE_KEEP | Kept | Silkscreen reference text position only; likely readability adjustment. |
| 3 | D102 | REF text shape | position = 5.6794 mm 0 mm | SAFE_KEEP | Kept | Silkscreen reference text position only; likely readability adjustment. |
| 4 | J11 | REF text shape | position = 5.0272 mm -3.6193 mm | SAFE_KEEP | Kept | Silkscreen reference text position only; likely readability adjustment on connector label. |
| 5 | U_RS232_2 | REF text shape | active = false | SAFE_KEEP | Kept | Hides reference text only; may be intentional to reduce silkscreen clutter around IC. |
| 6 | J_DWIN | REF text shape | active = false | SAFE_KEEP | Kept | Hides reference text only; may be intentional to reduce clutter near connector. |
| 7 | U_RS485 | REF text shape | position = 0.0425 mm 7.3652 mm; active = false | SAFE_KEEP | Kept | Silkscreen reference text visibility/position; does not affect RS485 routing or footprint. |
| 8 | U_DIGISO2 | REF text shape | active = false | SAFE_KEEP | Kept | Hides reference text only; may be intentional to reduce silkscreen clutter. |
| 9 | U_ISO2 | REF text shape | position = -0.115 mm 2.646 mm | SAFE_KEEP | Kept | Silkscreen reference text position only; likely readability adjustment. |
| 10 | U_ISO2 | REF text shape | active = false | SAFE_KEEP | Kept | Hides reference text only; may be intentional label cleanup. |
| 11 | D_RS485 | REF text shape | position = 0 mm 3.1923 mm | SAFE_KEEP | Kept | Silkscreen reference text position only; does not affect RS485 routing or footprint. |
| 12 | U_DIGISO2 | REF text shape | position = 0.926 mm 4.1524 mm | SAFE_KEEP | Kept | Silkscreen reference text position only; likely readability adjustment. |
| 13 | D101 | REF text shape | active = false | SAFE_KEEP | Kept | Hides reference text only; may be intentional label cleanup. |
Summary
Classification