PCB Net Routing Completion
J_DWIN sang connector FFC/FPC 10 pin pitch 1.0 mm. Trước tiên mình lưu lại toàn bộ kết nối pin hiện tại, tìm đúng linh kiện 1.0 mm trong thư viện, thay component rồi nối lại đúng 10 chân và kiểm tra lại.J_DWIN vì phiên làm việc đã hết credit ngay sau khi bắt đầu bước thay linh kiện.J_DWIN hiện tại là FFC2B35-10-G, 10 pin, pitch 0.5 mm.J_DWIN.J_DWIN cũ bằng connector 1.0 mm.J_RJ45_EXT.J_RJ45_EXT area checked: component center approximately X=-15.11 mm, Y=-35.00 mm; body approximately 20.06 mm x 19.16 mm.J_RJ45_EXT pads/UIDs directly.Table
| # | DRC type | DRC item | Location / nearest object | Net name / inferred net |
|---|---|---|---|---|
| 1 | Airwire | Trace f206 | Routed segment pair, not near RJ45 by UID | Not exposed by DRC |
| 2 | Airwire | Trace d37a | Near component UID 96d2818c... pad P1 | Not exposed by DRC |
| 3 | Airwire | Trace a119 | Routed segment pair | Not exposed by DRC |
| 4 | Airwire | Trace 40ae | Routed segment pair | Not exposed by DRC |
| 5 | Airwire | Trace d9fb | Near 0bafa02c... pad | Not exposed by DRC |
| 6 | Airwire | Trace 48bc | Routed segment pair | Not exposed by DRC |
| 7 | Floating copper | 1341aa9d | Floating through-hole/via copper | No net / floating |
| 8 | Floating copper | 3b90c07e | Floating through-hole/via copper | No net / floating |
| 9 | Floating copper | 5ed91a39 | Floating through-hole/via copper | No net / floating |
| 10 | Floating copper | e83a64db | Floating through-hole/via copper | No net / floating |
| 11 | Overlapping copper | P1 | Near R14 P1 / copper UID 621afec3... | likely local RS2322 signal path |
| 12 | Overlapping copper | 09e9b108 | Through-hole/via overlaps C21 P1 | likely local decoupling/power node |
| 13 | Overlapping copper | 0a187cca | Through-hole/via overlaps component UID b0d2c5b2... P1 | Not exposed by DRC |
| 14 | Overlapping copper | 12dd5fdc | Through-hole/via overlaps component UID a0863b93... P1 | Not exposed by DRC |
| 15 | Overlapping copper | P1 | Near C25 P1 and through-hole/via 7d0b6ff5... | likely RS2322 charge-pump node |
| 16 | Overlapping copper | P1 | Near C25 P1 and copper UID eeb56795... | likely RS2322 charge-pump node |
| 17 | Overlapping copper | P2 | Near C19 P2 and through-hole/via d6ccdab8... | likely RS2321 charge-pump node |
| 18 | Overlapping copper | P1 | Near R4 P1 and copper UID 625be59c... | DWIN divider / DWIN_TXD path |
| 19 | Overlapping copper | 3f56de2e | Through-hole/via overlaps R5 P2 | DWIN divider / GND-side node |
| 20 | Overlapping copper | 53acdd41 | Through-hole/via overlaps C23 P2 | likely RS2322 charge-pump node |
| 21 | Overlapping copper | P2 | Near R5 P2 / copper UID cb400317... | DWIN divider / GND-side node |
| 22 | Overlapping copper | P1 | Near R5 P1 / copper UID cb400317... | DWIN divider node |
| 23 | Overlapping copper | P2 | Near component UID 837059bb... P2 / copper UID b6938f3a... | Not exposed by DRC |
| 24 | Overlapping copper | P2 | Near component UID 837059bb... P2 / copper UID f3f4c2ee... | Not exposed by DRC |
| 25 | Overlapping copper | 8c55c47a | Through-hole/via overlaps component UID be2eab97... P1 | Not exposed by DRC |
| 26 | Overlapping copper | P2 | Near component UID 96d2818c... P2 / copper UID a48ee762... | Not exposed by DRC |
| 27 | Overlapping copper | P2 | Near component UID 96d2818c... P2 / trace d37abfef... | Not exposed by DRC |
J_RJ45_EXT and checked the current DRC error UID list.J_RJ45_EXT UID: acef3e72-21d7-4916-a0fd-797af4ca8d7fJ_RJ45_EXT.J10, J_LCD_EXT, R_EXT*, and J_RJ45_EXT. This is routing congestion, not a current RJ45 floating/overlapping copper DRC item. Clearing it would likely require moving connectors/passives or changing routing beyond the strict RJ45-only copper cleanup scope.Summary
27 Remaining DRC Errors
RJ45-local action taken