Corrected the footprint to Microchip’s recommended 14-pin TSSOP land pattern:
- Pad size: 0.45 × 1.45 mm
- Pad-row center spacing: 5.90 mm
- Lead pitch retained: 0.65 mm
- All 14 pads updated symmetrically
The apparent 1000× error was a unit-display mismatch: internal geometry was reported in meters, while the footprint source uses millimeters. The effective pad geometry is now explicitly set to the datasheet dimensions.