Integrated the two native PC817 homing sensor channels with labeled X/Y sensor terminals, 10kΩ pullups, 100nF filters, 4.7kΩ status LED resistors, Nano D9/D10 outputs, and a single 0Ω star link between GND_24V and GND_LOGIC.
Preserved the 100 mm × 152 mm, 2-layer board and placed the new/updated sensor parts in the connector area with no placement overlap or out-of-bounds issues.
Applied the required 1.6 mm copper spacing rule conservatively and documented the implementation in Homing Sensor Integration Audit.
Success criteria review
✅ Native X/Y sensor circuitry integrated and connected to +24V_SENSOR / GND_24V.
✅ LIMIT_X_NET connects to Nano D9; LIMIT_Y_NET connects to Nano D10.
✅ Sensor terminals are documented as BRN/BLU/BLK and filters/status LEDs are included.
✅ Board size and 2-layer stackup are preserved.
❌ Final layout DRC is not clean: airwires and overlapping copper remain after the stricter spacing rule, so the board is not fabrication-ready yet.
Next steps
Run routing cleanup/autoroute for the updated board, then re-check DRC until the airwire and copper-clearance issues are cleared. I can continue with PCB routing/cleanup guidance next.
Set LED colors: LED1/LED7 red, LED2 yellow, LED3/LED4 green, LED5/LED6 blue.
Marked U5 HX711 as optional-populate SOIC-16.
Wired power rails, UART level shifters, stepper outputs, sensor optos/filters, HX711/SD/OLED headers, relay header/indicator, button box, spare expansion, status LEDs, and test points.
Cleared floating-pin and no-connect ERC warnings by wiring spare level-shifter channels and marking intentionally unused module/mechanical pins.
Set PCB outline to 100 mm × 152 mm and stackup to Standard 2 Layer.
Applied baseline 0.2 mm trace/spacing and 0.6/0.3 mm via intent.
Placed all 65 components on the top side with mounting holes at 5 mm corner offsets and connectors on the perimeter.
Known deviations / remaining work
J9 uses an 8-position Phoenix terminal block available in the Flux library, but its pitch is 3.50 mm because an exact 8-position 5.08 mm MKDS-1.5/N library part was not available.
The board is placed but not routed; current review reports 103 airwire issues, meaning traces still need to be routed.
Bottom-layer solid GND pour and via stitching intent is configured at a high level, but final copper-fill/routing verification remains pending after routing.
Final silkscreen readability, connector pin labels, and JLCPCB production review remain pending after routing.