Part Review and Datasheet Verification
alt024-10e-part-review).https://www.nve.com/Downloads/ALTxxx-10.pdf. Main mismatches are that Part Type is set to “Transistors” instead of sensor/magnetometer, and pad 7 is labeled/type-treated as GND-PAD / Power In even though the datasheet describes it as an exposed leadframe pad, not GND.Table
| Pin / pad | Datasheet name | Datasheet function | Project symbol/footprint label | Result |
|---|---|---|---|---|
| 1 | Out+ | Positive bridge output | OUT+ | Match |
| 2 | NC | No internal connection | NC | Match |
| 3 | GND | Negative bridge supply / ground | GND | Match |
| 4 | Out− | Negative bridge output | OUT- | Match |
| 5 | NC | No internal connection | NC | Match |
| 6 | VCC | Positive bridge supply | VCC | Match |
| 7 / center exposed pad | Exposed pad / leadframe | Internally connected to leadframe, not specified as GND or VCC | GND-PAD | Mismatch / should be renamed or described as exposed pad / leadframe |
Sources
Current part metadata reviewed
Datasheet key specs
Datasheet pinout
Footprint cross-check
Mismatches and recommendations
Overall verdict