NC3FAH2, while the part uses NC3FAH-2.TO, six schematic terminals, missing pin descriptions, and pads 5/6 look incorrect.5/6 likely should be NPTH mechanical holes, not nettable copper pads.1, 2, 3, and G.silicon-yard/nc3fah-2https://storage.googleapis.com/graviton-electric-symbols/document_assets/user-uploaded/e5cf95e5433f4cab7a15b1174c9cc7458287c19b1a687f35a77e79d19f258f4b.pdfhttps://www.neutrik.com/en/product/nc3fah2https://www.neutrik.com/en/product/nc3fah2.pdfJack_XLR_Neutrik_NC3FAH2_HorizontalTable
| Field | Current value | Datasheet / official value | Review |
|---|---|---|---|
| Project / part name | NC3FAH-2 | NC3FAH2 | Mismatch: official Neutrik product title uses NC3FAH2 without the hyphen. |
| Manufacturer Part Number | NC3FAH-2 | NC3FAH2 | Mismatch / alias risk. Recommended primary MPN is NC3FAH2. |
| Manufacturer Name | Neutrik | Neutrik | Matches. |
| Description | Connector, PCB; Receptacle; 3 to 5 | 3 pole female XLR receptacle, separate shell/front-panel ground, horizontal PCB mount | Current description is too generic and ambiguous. |
| Part Type | Connectors | Connector / XLR connector | Mostly correct category, but should ideally be singular Connector and include XLR details. |
| Package or Case Code | TO | XLR receptacle, A-series, horizontal PCB through-hole | Mismatch: TO is not appropriate for this connector. |
| Mount | PCB | Horizontal PCB mount / through-hole | Mostly correct but should be more specific. |
| Datasheet URL | Google-storage PDF already set | Official Neutrik PDF also found | Existing URL was present, so no Datasheet URL update was required by the request. Official direct PDF is listed above. |
| Pads / terminals | 6 | 4 electrical terminals plus 2 mechanical NPTH holes | Likely mismatch: mechanical holes appear promoted to electrical pads/terminals. |
Table
| Spec | Value |
|---|---|
| Product | NC3FAH2 |
| Manufacturer | Neutrik |
| Connector type | 3-pole female XLR receptacle |
| Grounding | Separate ground contact to mating connector shell and front panel; no connection to Pin 1 |
| Wiring / mount | Horizontal PCB mount, rear mounting, A-screw, A-series chassis shape |
| Rated current | 6 A per contact |
| Rated voltage | 10 GΩ initial |
| Insertion / withdrawal force | 1000 mating cycles |
| Contacts | Bronze CuSn6, hard gold contact areas |
| Insert | Polyamide PA 6.6 |
| Protection class | IP40 |
| Temperature range | -30 °C to +80 °C |
| Flammability | UL 94 V-0 |
| Standard | IEC 61076-2-103 |
Table
| Terminal shown | Pin Number property | Pin Type | Pin Description | Review |
|---|---|---|---|---|
| 1 | 1 | Unspecified | Missing | Should be passive; description: XLR contact 1. |
| 2 | 2 | Unspecified | Missing | Should be passive; description: XLR contact 2. |
| 3 | 3 | Unspecified | Missing | Should be passive; description: XLR contact 3. |
| G | 4 | Unspecified | Missing | Should be named/described as shell/front-panel ground, separate from Pin 1. If possible, pin number should be G, not numeric 4. |
| 5 | 5 | Unspecified | Missing | Likely should not be a schematic terminal; appears to correspond to a mechanical hole. |
| 6 | 6 | Unspecified | Missing | Likely should not be a schematic terminal; appears to correspond to a mechanical hole. |
1, 2, 3, and G only. The two mechanical support holes should not be nettable schematic pins unless the manufacturer drawing explicitly identifies them as plated/electrical contacts.Table
| Current pad | At (mm) | Size (mm) | Drill (mm) | Review |
|---|---|---|---|---|
| 1 | (0.000, 0.000) | 2.4 x 2.4 | 1.6 | Electrical pad; annular ring smaller than KiCad reference. |
| 2 | (7.620, 0.635) | 2.4 x 2.4 | 1.6 | Electrical pad; coordinates look like a rotated reference footprint. |
| 3 | (3.810, 4.450) | 1.8 x 1.8 | 1.2 | Electrical pad; annular ring smaller than KiCad reference. |
| 4 / G | (-3.810, -5.720) | 1.8 x 1.8 | 1.2 | Shell/front-panel ground should be named G; numeric pad 4 is semantically risky. |
| 5 | (7.620, -4.450) | 2.4 x 2.4 | 1.6 | Likely should be NPTH mechanical hole, not copper/nettable pad. |
| 6 | (0.000, -8.890) | 2.4 x 2.4 | 1.6 | Likely should be NPTH mechanical hole, not copper/nettable pad. |
Table
| Reference feature | At (mm) | Size (mm) | Drill (mm) |
|---|---|---|---|
| Pad 1 | (0, 0) | 3.4 x 3.4 | 1.6 |
| Pad 2 | (-0.635, 7.62) | 3.4 x 3.4 | 1.6 |
| Pad 3 | (-4.45, 3.81) | 2.9 x 2.9 | 1.2 |
| Pad G | (5.72, -4.44) | 2.9 x 2.9 | 1.2 |
| NPTH | (3.81, 7.62) | 1.6 x 1.6 | 1.6 |
| NPTH | (8.89, 0) | 1.6 x 1.6 | 1.6 |
5 and 6 is a likely functional/library issue. Pad copper sizes are also smaller than the KiCad reference, reducing annular ring and mechanical robustness for a connector.NC3FAH2, while the part uses NC3FAH-2.Package or Case Code = TO is inappropriate for this XLR connector.1, 2, 3, and G only.5 and 6 likely represent mechanical NPTH holes and should not be nettable schematic terminals.G is modeled with Pin Number 4; the official/reference naming uses G for the separate shell/front-panel ground contact.Unspecified; connector pins should normally be Passive, with G described as shell/chassis/front-panel ground.5 and 6 likely should be NPTH mechanical holes, not copper pads.NC3FAH2 and a connector-specific package/case value.1, 2, 3, and G only.Passive or equivalent.G rather than numeric 4 if supported.Sources checked
Existing part information in Flux
Key official specifications
Symbol / terminal review
Footprint review
Mismatches / issues flagged
Actions taken