Datasheet Review


Review all available part information (MPN, package, pin count, description, properties). If no datasheet URL is already set, search the web for the official datasheet and update the part's Datasheet property with the URL. Then cross-check the schematic symbol, footprint, and pin descriptions against the datasheet. Summarize key specs and flag any mismatches.
I’ll inspect the current part metadata/symbol/footprint, find the official datasheet if needed, then cross-check pins and package details against it and record the detailed review in a project document.
I found an official Analog Devices PDF and the part already has a Datasheet URL set, so I’m using the official PDF for the verification without changing that property. The main issue so far is metadata/package naming: the current Package or Case Code is TO, while the datasheet calls this 10‑TDFN‑EP, 3 × 3 mm, package code T1033+1C.
Completed the datasheet review and updated MAX17615ATB+ Part Datasheet Review.
Open items:
  • Datasheet URL already exists, so I did not change it; the document notes the better direct ADI PDF URL.
  • Mismatches flagged: Package or Case Code = TO, library subtype Logic / AND, and suspicious mount = Reverse.
  • Symbol pinout and pin descriptions match the datasheet; footprint looks broadly consistent but should be validated against ADI land pattern 90-0003 for production release.
Suggested next steps:
  1. Correct the package metadata to T1033+1C / 10-TDFN-EP 3x3.
  2. Normalize the Datasheet URL to the direct ADI PDF.
  3. Fix the library classification metadata from logic to power-management/current-limiter.
Fix metadata and review
Fix part metadata
Fix classification
Check footprint pattern
Run ERC/DRC review

UVLO
Pin Number
2
FLAG
Pin Number
6
UVOV
Pin Number
7
OUT
Pin Number
10
GND
Pin Number
9
EP
Pin Number
11
IN
Pin Number
1
CLMODE
Pin Number
4
SETI
Pin Number
8
EN
Pin Number
5
OVLO
Pin Number
3
Name
Pin #
Type
Part Type
Pin Description
Pin Group
IN
1
Power In
Terminal
Input pin; connect a low-ESR ceramic capacitor to GND. For hot plug-in applications, see datasheet application information.
Power
UVLO
2
Input
Terminal
UVLO adjustment; connect resistive divider from IN to GND to set UVLO threshold.
Control
OVLO
3
Input
Terminal
OVLO adjustment; connect resistive divider from IN to GND to set OVLO threshold.
Control
CLMODE
4
Input
Terminal
Current-limit mode selector: GND = continuous, 150kΩ to GND = latch-off, open = autoretry.
Control
EN
5
Input
Terminal
Active-high enable input; internally pulled up to 1.6V.
Control
FLAG
6
Open Collector
Terminal
Open-drain fault indicator output; pulls low for overcurrent after blanking time, reverse current, invalid RSETI, or reverse polarity on OUT while IN is valid.
Status
UVOV
7
Open Collector
Terminal
Open-drain UV/OV fault output; pulls low when input falls below UVLO falling threshold or rises above OVLO rising threshold.
Status
SETI
8
Bi-Directional
Terminal
Overcurrent-limit adjustment pin and current-monitor output; connect resistor from SETI to GND. Do not connect more than 10pF to SETI.
Control
GND
9
Ground
Terminal
Ground.
Ground
OUT
10
Power Out
Terminal
Output pin. For long output cable or inductive load, see datasheet application information.
Power
EP
11
Ground
Terminal
Exposed pad; connect to a large GND plane with several thermal vias for best thermal performance.
Ground

MAX17615ATB+