Critical mismatches: footprint row spacing is 8.53 mm versus 8.89 mm specified; pads are 1.67 mm long versus 1.27 mm recommended. Symbol pins lack functional names/descriptions and the transformer/choke topology is unclear.
Assessment: not recommended for production as-is. I filed a part-quality report with the Flux engineering team.
You’re correct—the datasheet land pattern is approximately 0.76 × 1.71 mm at 1.27 mm pitch, matching the footprint’s 0.76 × 1.67 mm pads within rounding/tolerance.
I corrected the H1102NLT Part Audit and removed the erroneous footprint mismatch and production warning. The only remaining recommendation is improving the schematic pin names/descriptions and transformer topology for readability.