Part Datasheet Review


Updated all 65 terminals so Pin Group and Section are populated and identical using broad functional groups: Power, Ground, Cell Monitor, Communication, GPIO, Current Sense, and Thermal Pad.
Open items:
  • AVSS_2 remains grouped as Thermal Pad because pin 65 is the exposed PowerPAD, not a normal datasheet pin.
Suggested next steps:
  1. Rename AVSS_2 to PowerPAD or EP.
  2. Rebuild the HTQFP-64 PAP footprint.
  3. Run part review checks after the footprint is fixed.
Assign Terminal Order and Pin Orientation, then run a schematic/symbol review.
I’ll assign terminal order and orientation by broad groups using your conventions, then run symbol/part checks and verify the schematic metadata.
Assigned Terminal Order and Pin Orientation for all 65 terminals: Power = order 1/top, Cell Monitor = 2/left, Communication = 3/right, GPIO = 4/right, Current Sense = 5/left, Thermal Pad = 9/bottom, Ground = 10/bottom.
Open items:
  • Schematic/symbol review returned no open warnings/errors for the checked component-review categories.
  • Footprint quality is still a separate unresolved issue from the prior review.
Suggested next steps:
  1. Rebuild the HTQFP-64 PAP0064F footprint.
  2. Run footprint/layout checks after footprint generation.
  3. Publish the part once footprint checks pass.
Build footprint and checks
Rebuild footprint
Run footprint checks
Prepare for publishing

CB0
Pin Number
34
BAT
Pin Number
1
AVSS_1
Pin Number
39
COMLN
Pin Number
41
GPIO5
Pin Number
57
REFHP
Pin Number
37
CB11
Pin Number
12
CB2
Pin Number
30
CB14
Pin Number
6
COMHN
Pin Number
42
CB4
Pin Number
26
CB5
Pin Number
24
VC14
Pin Number
7
GPIO8
Pin Number
54
COMLP
Pin Number
40
CVDD
Pin Number
45
VC12
Pin Number
11
CB6
Pin Number
22
VC4
Pin Number
27
LDOIN
Pin Number
47
CB10
Pin Number
14
VC10
Pin Number
15
VC8
Pin Number
19
DVDD
Pin Number
49
NPNB
Pin Number
48
VC0
Pin Number
35
CB9
Pin Number
16
GPIO7
Pin Number
55
RX
Pin Number
52
GPIO1
Pin Number
61
VC16
Pin Number
3
CB12
Pin Number
10
VC5
Pin Number
25
VC2
Pin Number
31
VC15
Pin Number
5
TX
Pin Number
53
COMHP
Pin Number
43
VC11
Pin Number
13
GPIO3
Pin Number
59
VC13
Pin Number
9
CB15
Pin Number
4
GPIO2
Pin Number
60
AVDD
Pin Number
38
TSREF
Pin Number
51
SRP
Pin Number
64
CB16
Pin Number
2
EP
Pin Number
65
GPIO4
Pin Number
58
GPIO6
Pin Number
56
VC1
Pin Number
33
CB1
Pin Number
32
VC3
Pin Number
29
DVSS
Pin Number
50
CVSS
Pin Number
46
REFHM
Pin Number
36
VC6
Pin Number
23
VC9
Pin Number
17
SRN
Pin Number
63
CB8
Pin Number
18
CB13
Pin Number
8
NFAULT
Pin Number
62
CB3
Pin Number
28
NEG5V
Pin Number
44
VC7
Pin Number
21
CB7
Pin Number
20
Name
Pin #
Type
Part Type
Pin Description
Pin Group
BAT
1
Power In
Terminal
Power supply input and top-of-module measurement input. Connect to the top cell of the battery module.
Power
CB16
2
Bi-Directional
Terminal
Cell balance connection for cell 16; connected to internal cell-balancing FET. Connect to the positive terminal of cell 16 with a differential RC filter to CB15; filter resistor sets internal balance current.
Cell Monitor
VC16
3
Input
Terminal
Cell voltage sense input for cell 16. Connect to the positive terminal of cell 16 with a differential RC filter to VC15.
Cell Monitor
CB15
4
Bi-Directional
Terminal
Cell balance connection for cell 15; connected to internal cell-balancing FET. Connect to the positive terminal of cell 15 with a differential RC filter to CB14; filter resistor sets internal balance current.
Cell Monitor
VC15
5
Input
Terminal
Cell voltage sense input for cell 15. Connect to the positive terminal of cell 15 with a differential RC filter to VC14.
Cell Monitor
CB14
6
Bi-Directional
Terminal
Cell balance connection for cell 14; connected to internal cell-balancing FET. Connect to the positive terminal of cell 14 with a differential RC filter to CB13; filter resistor sets internal balance current.
Cell Monitor
VC14
7
Input
Terminal
Cell voltage sense input for cell 14. Connect to the positive terminal of cell 14 with a differential RC filter to VC13.
Cell Monitor
CB13
8
Bi-Directional
Terminal
Cell balance connection for cell 13; connected to internal cell-balancing FET. Connect to the positive terminal of cell 13 with a differential RC filter to CB12; filter resistor sets internal balance current.
Cell Monitor
VC13
9
Input
Terminal
Cell voltage sense input for cell 13. Connect to the positive terminal of cell 13 with a differential RC filter to VC12.
Cell Monitor
CB12
10
Bi-Directional
Terminal
Cell balance connection for cell 12; connected to internal cell-balancing FET. Connect to the positive terminal of cell 12 with a differential RC filter to CB11; filter resistor sets internal balance current.
Cell Monitor
VC12
11
Input
Terminal
Cell voltage sense input for cell 12. Connect to the positive terminal of cell 12 with a differential RC filter to VC11.
Cell Monitor
CB11
12
Bi-Directional
Terminal
Cell balance connection for cell 11; connected to internal cell-balancing FET. Connect to the positive terminal of cell 11 with a differential RC filter to CB10; filter resistor sets internal balance current.
Cell Monitor
VC11
13
Input
Terminal
Cell voltage sense input for cell 11. Connect to the positive terminal of cell 11 with a differential RC filter to VC10.
Cell Monitor
CB10
14
Bi-Directional
Terminal
Cell balance connection for cell 10; connected to internal cell-balancing FET. Connect to the positive terminal of cell 10 with a differential RC filter to CB9; filter resistor sets internal balance current.
Cell Monitor
VC10
15
Input
Terminal
Cell voltage sense input for cell 10. Connect to the positive terminal of cell 10 with a differential RC filter to VC9.
Cell Monitor
CB9
16
Bi-Directional
Terminal
Cell balance connection for cell 9; connected to internal cell-balancing FET. Connect to the positive terminal of cell 9 with a differential RC filter to CB8; filter resistor sets internal balance current.
Cell Monitor
VC9
17
Input
Terminal
Cell voltage sense input for cell 9. Connect to the positive terminal of cell 9 with a differential RC filter to VC8.
Cell Monitor
CB8
18
Bi-Directional
Terminal
Cell balance connection for cell 8; connected to internal cell-balancing FET. Connect to the positive terminal of cell 8 with a differential RC filter to CB7; filter resistor sets internal balance current.