Completed the part review and created the detailed report: Part Information Review — HARTING 09231326921. The Datasheet URL was already set, so I did not change it; the key issue found is the footprint mounting-hole spacing: current 48.62 mm vs. official 48.26 ±0.05 mm.
Open items:
Correct MH1/MH2 X coordinates before relying on the footprint mechanically.
Add pin descriptions and set connector pins to Passive/Bi-Directional.
Clarify MH1/MH2 as mechanical/fixing holes unless electrically intentional.
Suggested next steps:
Fix the mounting-hole coordinates.
Update pin descriptions/types.
Re-run a footprint/symbol verification after edits.