Importing Altium PCB Project Issues
Talk to Flux to get started.
Table
| Item | X center | Y center | Pass |
|---|---|---|---|
| Upper AD9363 | 32.0 mm | 22.0 mm | ☐ |
| Lower AD9363 | 32.0 mm | 8.0 mm | ☐ |
Table
| Block | X min | X max | Y min | Y max | Pass |
|---|---|---|---|---|---|
| M.2 connector / host keepout | 0.0 | 8.0 | 0.0 | 30.0 | ☐ |
| Power conversion band | 8.0 | 16.0 | 2.0 | 28.0 | ☐ |
| FPGA core region | 14.0 | 24.0 | 8.0 | 22.0 | ☐ |
| Digital escape corridor | 24.0 | 30.0 | 6.0 | 24.0 | ☐ |
| Upper AD9363 region | 28.0 | 36.0 | 17.0 | 27.0 | ☐ |
| Lower AD9363 region | 28.0 | 36.0 | 3.0 | 13.0 | ☐ |
| Upper RX pair region | 36.0 | 52.0 | 16.0 | 29.0 | ☐ |
| Lower RX pair region | 36.0 | 52.0 | 1.0 | 14.0 | ☐ |
| Center spine keep-clear | 24.0 | 52.0 | 14.0 | 16.0 | ☐ |
Table
| Lane | Y centerline | Pass |
|---|---|---|
| RX1 | 26.0 mm | ☐ |
| RX2 | 19.0 mm | ☐ |
| RX3 | 11.0 mm | ☐ |
| RX4 | 4.0 mm | ☐ |
Table
| Lane | X min | X max | Y min | Y max | Pass |
|---|---|---|---|---|---|
| RX1 | 36.0 | 52.0 | 23.0 | 29.0 | ☐ |
| RX2 | 36.0 | 52.0 | 16.0 | 22.0 | ☐ |
| RX3 | 36.0 | 52.0 | 8.0 | 14.0 | ☐ |
| RX4 | 36.0 | 52.0 | 1.0 | 7.0 | ☐ |
Table
| Segment | X min | X max | Pass |
|---|---|---|---|
| RF entry / launch | 49.0 | 52.0 | ☐ |
| Protection / first shunt | 46.5 | 49.0 | ☐ |
| Matching A | 43.5 | 46.5 | ☐ |
| Filter / gain / conditioning | 40.0 | 43.5 | ☐ |
| Matching B / coupling | 37.0 | 40.0 | ☐ |
| RFIC entry run | 36.0 | 37.0 | ☐ |
Table
| Check | Target | Pass |
|---|---|---|
| Same part count | Exact | ☐ |
| Same part order | Exact | ☐ |
| Same X positions | <= 0.10 mm mismatch | ☐ |
| Same body angles | 0 deg mismatch | ☐ |
| Same segment count | Exact | ☐ |
| Segment length mismatch | <= 0.25 mm | ☐ |
| Total route mismatch | <= 0.50 mm | ☐ |
| Final RFIC entry mismatch | <= 0.20 mm | ☐ |
Table
| Check | Target | Pass |
|---|---|---|
| Same part count | Exact | ☐ |
| Same part order | Exact | ☐ |
| Same X positions | <= 0.10 mm mismatch | ☐ |
| Same body angles | 0 deg mismatch | ☐ |
| Same segment count | Exact | ☐ |
| Segment length mismatch | <= 0.25 mm | ☐ |
| Total route mismatch | <= 0.50 mm | ☐ |
| Final RFIC entry mismatch | <= 0.20 mm | ☐ |
Table
| Comparison | Target | Pass |
|---|---|---|
| RX1 vs RX4 | Same outer-lane topology | ☐ |
| RX2 vs RX3 | Same inner-lane topology | ☐ |
| Upper pair vs lower pair | Same template architecture | ☐ |
| Upper RFIC entry style vs lower RFIC entry style | Same geometry family | ☐ |
| Upper support region vs lower support region | Same support topology | ☐ |
Table
| Parameter | RX1 vs RX2 | RX3 vs RX4 | RX1 vs RX4 | RX2 vs RX3 | Pass Rule |
|---|---|---|---|---|---|
| Total RF length | Match | Match | Equivalent | Equivalent | <= 0.50 mm pair mismatch, <= 0.75 mm pair-to-pair |
| Segment lengths | Match | Match | Equivalent | Equivalent | <= 0.25 mm |
| Via count | Exact | Exact | Exact | Exact | 0 mismatch |
| Via type | Exact | Exact | Exact | Exact | same type and drill |
| Layer sequence | Exact | Exact | Exact | Exact | same transitions |
| Bend count | Exact | Exact | Exact | Exact | 0 mismatch |
| Bend style | Exact | Exact | Exact | Exact | same style and locations |
| Neckdowns | Exact | Exact | Exact | Exact | same count and X positions |
| Stub count | Exact | Exact | Exact | Exact | 0 mismatch |
| Reference plane continuity | Exact | Exact | Exact | Exact | no unique split crossing |
| Final RFIC entry | Match | Match | Equivalent | Equivalent | <= 0.20 mm mismatch |
Table
| Support item | Upper region | Lower region | Pass rule | Pass |
|---|---|---|---|---|
| Decoupling count per rail | Same | Same | Exact | ☐ |
| Nearest-cap pattern | Same | Same | Mirror/equivalent | ☐ |
| Clock/reference support topology | Same | Same | Exact class | ☐ |
| Ground-return via count | Same | Same | Exact | ☐ |
| Analog support routing style | Same | Same | Exact topology | ☐ |
| Power-feed branch style | Same | Same | Exact branch logic | ☐ |
| Digital fanout style | Same | Same | Equivalent | ☐ |
| Keepout to center spine | Same | Same | preserved | ☐ |
| Shield/guard use | Same | Same | exact if used | ☐ |
Table
| Layer | Nominal role | Copper target | Dielectric target to next layer | Notes | Pass |
|---|---|---|---|---|---|
| L1 | Top signal / RF / critical escape | 1 oz finished target | L1-L2: 0.10 mm to 0.13 mm | Primary controlled-impedance layer for RX lanes and sensitive single-ended routing | ☐ |
| L2 | Solid ground plane | 1 oz finished target | L2-L3: 0.20 mm to 0.30 mm | Keep as continuous as possible under RX lanes, both AD9363 regions, and key digital paths | ☐ |
| L3 | Power plane plus secondary signal | 0.5 oz to 1 oz finished target | L3-L4: 0.10 mm to 0.13 mm | Use for power distribution and limited non-RF escape routing | ☐ |
| L4 | Bottom signal / support routing | 1 oz finished target | n/a | Secondary signal layer only; avoid making one RX lane unique by moving it here alone | ☐ |
Table
| Copper region | Planning target | Final fab value | Pass |
|---|---|---|---|
| Outer layers | 1 oz | ☐ | |
| Inner ground layer | 1 oz | ☐ | |
| Inner power / secondary layer | 0.5 oz to 1 oz | ☐ |
Table
| Dielectric pair | Planning target | Final fab value | Pass |
|---|---|---|---|
| L1-L2 | 0.10 mm to 0.13 mm | ☐ | |
| L2-L3 | 0.20 mm to 0.30 mm | ☐ | |
| L3-L4 | 0.10 mm to 0.13 mm | ☐ |
Table
| Net class | Target impedance | Preferred layer / structure | Notes | Pass |
|---|---|---|---|---|
| RX single-ended RF lanes | 50 ohm | L1 microstrip over solid L2 | Use identical geometry across RX1-RX4 | ☐ |
| Sensitive single-ended clocks if controlled | 50 ohm | L1 or L4 referenced to a solid plane | Keep peer routing identical where applicable | ☐ |
| High-speed differential digital pairs | 100 ohm differential | Coupled pair over solid reference plane | Use the same width / gap rule throughout each interface class | ☐ |
| Differential reference clocks | 100 ohm differential | Coupled pair over solid reference plane | Preserve symmetry and pair continuity | ☐ |
Table
| Parameter | Planning target | Final released value |
|---|---|---|
| Layer count | 4 | |
| Outer copper weight | 1 oz | |
| Inner ground copper weight | 1 oz | |
| Inner power / secondary copper weight | 0.5 oz to 1 oz | |
| L1-L2 dielectric | 0.10 mm to 0.13 mm | |
| L2-L3 dielectric | 0.20 mm to 0.30 mm | |
| L3-L4 dielectric | 0.10 mm to 0.13 mm | |
| 50 ohm single-ended width | planner to fill | |
| 100 ohm differential width | planner to fill | |
| 100 ohm differential gap | planner to fill | |
| Controlled-net via drill | planner to fill | |
| Stub-control or backdrill policy | planner to fill |
Table
| Corridor | Region | Allowed | Forbidden | Pass |
|---|---|---|---|---|
| Upper digital bus | X 24.0-32.0, Y 18.0-22.0 | FPGA to upper AD9363 digital | RX analog routing | ☐ |
| Lower digital bus | X 24.0-32.0, Y 8.0-12.0 | FPGA to lower AD9363 digital | RX analog routing | ☐ |
| Center spine | X 24.0-52.0, Y 14.0-16.0 | shared references only if unavoidable | channel-specific RF routing | ☐ |
| Upper RX pair region | X 36.0-52.0, Y 16.0-29.0 | RX1/RX2 only | lower pair routing | ☐ |
| Lower RX pair region | X 36.0-52.0, Y 1.0-14.0 | RX3/RX4 only | upper pair routing | ☐ |
Table
| Final check | Requirement | Pass |
|---|---|---|
| RFIC anchors locked | exact | ☐ |
| All lane boxes respected | exact | ☐ |
| Upper pair symmetry held | yes | ☐ |
| Lower pair symmetry held | yes | ☐ |
| Pair-to-pair equivalence held | yes | ☐ |
| Via counts match across all lanes | exact | ☐ |
| Bend counts match across all lanes | exact | ☐ |
| Layer transitions match across all lanes | exact | ☐ |
| Final RFIC entry geometry matched | yes | ☐ |
| RFIC support regions equivalent | yes | ☐ |
| Center spine preserved | yes | ☐ |
| No unique lane rescue routing | yes | ☐ |
30 mm x 52 mm board, dual AD9363, 4 matched RX lanes
1. Project intent
2. Coordinate system
3. Fixed anchor locations
RFIC anchors
RFIC placement rules
4. Placement regions
Main regions
5. RX lane centers and boxes
Lane centerlines
Lane placement boxes
6. RX lane template
7. Pair symmetry checks
Upper pair: RX1 vs RX2
Lower pair: RX3 vs RX4
8. Pair-to-pair equivalence checks
9. RF routing symmetry matrix
10. AD9363 support-region checklist
11. Stackup and controlled-impedance section
Layer count target
Recommended planning stackup
Layer role rules
Copper-weight targets
Dielectric targets
Controlled-impedance targets
Controlled-impedance notes
Fabrication and field-solver record
12. Reserved corridors
13. Go / no-go signoff
Final disposition
14. Reviewer notes