Adjustable Non-Inverting Op-Amp Design
Table
| Designator | Component & Value | Description & Connections |
|---|---|---|
| U1 | LM358 | Generic dual op amp. Use one op amp for the non-inverting amplifier configuration. |
| R1 | 10 kΩ | Fixed resistor from the U1 inverting (–) input to ground. |
| R2 | Potentiometer 0–100 kΩ | Adjustable feedback resistor connected from U1 output to the inverting (–) input. |
| C1 | 0.1 µF decoupling capacitor | Connected between U1 V+ (power) and ground to improve stability (placed adjacent to U1). |
| TP1 | Test point | Node at U1 output for connecting both the Arduino A0 and the oscilloscope probe. |
| ARDUINO | Arduino (assumed 5V supply and analog input A0) | U1 V+ will be tied to the Arduino’s +5V supply. The U1 output (via TP1) connects to the Arduino analog input (A0). |
| GND | Common Ground | All components (U1, R1, R2, C1, Arduino, oscilloscope) share a common ground. |
| IN | Input Signal | Input node feeding the U1 non-inverting (+) pin. |