Part Review and Datasheet Update
N/C display labels if strict naming consistency is required.Table
| Pin | Expected function | Current symbol label | Pin type | Description status |
|---|---|---|---|---|
| 1 | /HOLD or IO3 | /HOLD (IO3) | Bi-Directional | Added |
| 2 | VCC | VCC | Power In | Added |
| 3 | /RESET | /RESET | Input | Added |
| 4 | NC | NC | Not Connected | Added |
| 5 | NC | NC | Not Connected | Added |
| 6 | DNU | DNU | Reserved | Added |
| 7 | /CS | /CS | Input | Added |
| 8 | DO or IO1 | DO (IO1) | Bi-Directional | Added |
| 9 | /WP or IO2 | /WP (IO2) | Bi-Directional | Added |
| 10 | GND | GND | Ground | Added |
| 11 | DNU | DNU | Reserved | Added |
| 12 | NC | N/C | Passive | Added |
| 13 | NC | N/C | Passive | Added |
| 14 | NC | N/C | Passive | Added |
| 15 | DI or IO0 | DI (IO0) | Bi-Directional | Added |
| 16 | CLK | CLK | Input | Added |
NC.N/C in the current symbol/footprint despite rename attempts using the unique terminal identifiers. Their descriptions are correct, but the label rename did not persist through the available editor operation.NC consistently.SOIC-16_L10.3-W7.5-P1.27-LS10.3-BLMAX3232ECWE+TMAX3232ECWE+T, not W25Q02JVSFIM/Winbond. This is acceptable only if the mechanical package is identical, but it is a publishing-quality metadata issue.N/C to NC; the attempted batch rename did not persist.Datasheet URL property directly; the URL is present in project metadata/history but the datasheet query service previously did not recognize it.W25Q02JVSFIM_SOIC-16W_7.5x10.3mm_P1.27mm.kicad_modW25Q02JVSFIM_SOIC-16W_7.5x10.3mm_P1.27mm.stepPackage_SO:SOIC-16W_7.5x10.3mm_P1.27mm and matching KiCad STEP model, matching the W25Q02JVSFIM 16-SOIC / SOIC-W / 300 mil package class.Source reviewed
Existing project metadata
Key specifications
Symbol update status
Notes on NC naming
SOIC-16 footprint land-pattern audit
Footprint assessment
Remaining mismatches / recommendations
Footprint / 3D model replacement update