  • Device: Doseband X — Passive Colorimetric H2S Exposure-Dosimeter Wristband with optional electronic chemiresistive measurement.
  • Status: Approved for prototype design.
  • Purpose: Wearable monitoring platform combining a cumulative passive color strip with an electrically separate H2S-responsive cartridge and smartphone-assisted quantitative interpretation.
Intended Use
  • SIH 2026 engineering prototype for wearable H2S exposure indication and measurement development.
  • Not certified personal protective equipment or a life-safety gas alarm in this revision.
What the Device Should Do
  • Carry a disposable passive colorimetric H2S exposure strip.
  • Measure a separate two-electrode chemiresistive H2S cartridge through an ESP3...
The requirements, GPIO map, power budget, and critical H2S divider constraints are captured in the Project Specification. I’m now building the datasheet-backed schematic.
Created a thread
"Doseband X Schematic" completed.
The initial design pass created the Project Specification and added 58 real components, including the ESP32-S3-WROOM-1-N16R8, BQ24074 power-path charger, TPS63001 buck-boost regulator, SHTC3 sensor, USB-C/ESD circuitry, H2S interfaces, RGB LED, and motor-driver parts.
Open items
  • The project currently reports 0 nets, so the schematic has not been electrically wired or ERC-verified.
  • PCB outline, placement, antenna keepout, routing, ground plane, and DRC remain unfinished.
  • The added components still require reconciliation against the exact H2S path and GPIO mapping before layout.
Execution stopped because your ACUs ran out.

Start Auto-Layout


Last modified 2mo ago

Project Specification
Project Overview
  • Device: Doseband X — Passive Colorimetric H2S Exposure-Dosimeter Wristband with optional electronic chemiresistive measurement.
  • Status: Approved for prototype design.
  • Purpose: Wearable monitoring platform combining a cumulative passive color strip with an electrically separate H2S-responsive cartridge and smartphone-assisted quantitative interpretation.
Intended Use
  • SIH 2026 engineering prototype for wearable H2S exposure indication and measurement development.
  • Not certified personal protective equipment or a life-safety gas alarm in this revision.
What the Device Should Do
  • Carry a disposable passive colorimetric H2S exposure strip.
  • Measure a separate two-electrode chemiresistive H2S cartridge through an ESP32-S3 ADC input.
  • Compensate readings using temperature and humidity.
  • Communicate through native USB, Bluetooth, and Wi-Fi.
  • Support an external I2C OLED, RGB status indication, pushbutton, and vibration alert.
  • Operate from a rechargeable single-cell Li-Po battery and charge from USB-C.
Main Features
  • ESP32-S3 module with integrated antenna and production-ready flash/PSRAM.
  • USB-C sink with native USB data, CC resistors, ESD protection, and series termination.
  • Li-Po charger with power-path management and protected SYS rail.
  • Efficient regulated 3.3 V rail sized for ESP32 radio current peaks.
  • Temperature/humidity sensor on I2C.
  • Separate H2S cartridge contacts and selectable test-resistance substitute.
  • UART/debug access.
System Architecture

Diagram


ADC D+ / D- USB-C 5 V + USB Data Li-Po Charger and Power Path 1-cell Li-Po SYS Rail 3.3 V Regulator ESP32-S3 Temperature and Humidity Sensor I2C OLED Connector Chemiresistive H2S Divider RGB LED Vibration Motor Driver
Hardware Subsystems
  • Power / USB-C: USB-C receptacle, CC1/CC2 5.1 kΩ sink pull-downs, VBUS and USB data ESD protection.
  • Battery / Charging: Single-cell Li-Po connector, modern charger/power-path IC, conservative wearable-cell charging current, battery temperature support when practical.
  • 3.3 V Regulation: Low-IQ regulator capable of ESP32-S3 transient current without losing regulation across the usable Li-Po range.
  • Compute / RF: ESP32-S3 module, required boot/reset biasing, local decoupling, antenna keepout on every copper layer.
  • H2S Measurement: +3V3 → R_FIXED → H2S_ADC/GPIO4 → H2S_E1 → external sensing material → H2S_E2 → GND. No resistor across or below the cartridge.
  • Environmental Compensation: Compact low-power I2C temperature/humidity sensor with local decoupling.
  • User Interface: External OLED connector, low-current RGB LED, GPIO0 button, vibration motor MOSFET driver.
  • Debug: Native USB and accessible UART TX/RX plus reset/boot access.
Interfaces and Connections

Table


NetESP32-S3 assignmentPurpose
H2S_ADCGPIO4Chemiresistive divider measurement
I2C_SCLGPIO5I2C clock
I2C_SDAGPIO6I2C data
RGB_RGPIO15Red LED channel
RGB_GGPIO16Green LED channel
RGB_BGPIO17Blue LED channel
VIB_CTRLGPIO18Vibration driver control
BUTTONGPIO0Active-low user/boot button
USB_DMGPIO19Native USB D-
USB_DPGPIO20Native USB D+
Power and Runtime Expectations
  • Source: one protected or externally protected 1-cell Li-Po, nominal 3.7 V.
  • USB input: 5 V Type-C sink, no USB Power Delivery.
  • Runtime depends strongly on radio/display/motor duty cycle and battery capacity; firmware must use sleep and duty-cycled radios for wearable operation.
Power Tree and Preliminary Power Budget

Table


LoadTypical/active estimatePeak design allowance
ESP32-S3 module80–240 mA active500 mA radio transient
Temperature/humidity sensor<2 mA3 mA
External OLED20 mA40 mA
RGB LED3–9 mA15 mA
H2S dividerresistance-dependent<0.33 mA with 10 kΩ fixed resistor
Miscellaneous5 mA15 mA
3.3 V rail target~275 mA active≥600 mA transient capability
Vibration motor on SYS/VBAT60–100 mA150 mA startup allowance
The charger, battery connector, protection path, and SYS wiring should support at least 0.8 A transient load with margin. The 3.3 V regulator must be rated for at least 0.6 A and verified across the battery discharge range.
H2S Measurement Equation
  • V_ADC = 3.3 × R_SENSOR / (R_FIXED + R_SENSOR)
  • R_SENSOR = R_FIXED × V_ADC / (3.3 − V_ADC)
  • Initial R_FIXED target is 10 kΩ; it may be revised when the real sensing material resistance range is characterized.
  • A potentiometer or resistor network may be fitted only as H2S SENSOR TEST ONLY, selected instead of the real cartridge and never placed in parallel.
Manufacturing and Assembly Expectations
  • Standard 2-layer or 4-layer SMD PCB using obtainable manufacturer parts and verified footprints.
  • Prefer 0603 passives for prototype assembly where size permits; smaller packages only where placement density requires them.
  • Board approximately 55 mm × 25 mm with rounded corners; size may increase if routing or RF constraints require it.
Firmware-Relevant Hardware Requirements
  • Native USB programming/debug plus exposed UART TX/RX.
  • GPIO0 must remain correctly biased for normal boot and support manual download mode.
  • ADC acquisition should average/filter samples and reject rail-saturation readings.
  • Firmware must compensate the H2S estimate using temperature/humidity calibration data.
Physical Design Expectations
  • USB-C, battery, OLED, motor, and H2S cartridge interfaces accessible from board edges.
  • ESP32 antenna at an outward-facing edge with datasheet keepout on all layers.
  • H2S analog path short and separated from regulator switching nodes, motor current, and USB traces.
  • Temperature/humidity sensor isolated from charger, regulator, ESP32, motor, and other heat sources.
Important Design Decisions
  • The passive color strip is mechanically carried/read optically and is electrically independent.
  • The electrical cartridge is a true external two-electrode chemiresistive element, not a PCB resistor.
  • Native ESP32-S3 USB removes the need for a USB-UART bridge.
  • Power-path charging is preferred so the device can operate safely while connected to USB.
Assumptions
  • The Li-Po cell includes certified cell-level protection, while the PCB adds charger/power-path protection appropriate to the selected IC.
  • The external vibration motor is a small brushed coin motor compatible with the SYS/VBAT range.
  • The final fixed-divider resistor may require a build option after cartridge characterization.
  • This prototype is not yet certified for occupational safety or medical use.
Change Notes
  • Initial specification created from the supplied SIH 2026 requirements.
  • Project Overview

  • Intended Use

  • What the Device Should Do

  • Main Features

  • System Architecture

  • Hardware Subsystems

  • Interfaces and Connections

  • Power and Runtime Expectations

  • Power Tree and Preliminary Power Budget

  • H2S Measurement Equation