Next steps
The remaining ERC items are cleanup-level and not charger/function blockers. The main follow-up is to remove the unused standalone GND symbols, replace or rewire
D1 to a simpler VBUS TVS part, and decide whether the unused ESP32 and USB data pins should stay intentionally unconnected or be terminated/documented. I can do that cleanup pass next.