TI Pad Fix


Fix this issue:
Official TI DRB0008A data shows an 8-pin VSON plus one unnumbered exposed thermal pad tied to GND. Current Flux part has 13 terminals/pads: central EP plus four copper extensions numbered 9-13.
I’ll check TI’s DRB0008A drawing and the part’s terminal mappings, correct the exposed-pad representation, then verify the footprint.
Finished execution
"TPA2005D1DRBR Pad Fix" completed.
Corrected the source part to pins 1–8 plus one EP, removing bogus terminals 9–13 and merging TI’s copper extensions into the single exposed pad. Verified nine mapped pads; EP is Ground-typed but must be wired to GND in consuming designs.
Changes remain unpublished; automated DRC returned no result, and paste coverage still needs assembly review before release—details and evidence are in Exposed Pad Correction.

Pin #
Name
Type
Section
Pin Group
Orientation
Order
Sub-symbol
Pin Description
1
~SHUTDOWN
Unspecified
2
NC
Unspecified
3
IN+
Unspecified
4
IN-
Unspecified
5
VO+
Unspecified
6
VDD
Unspecified
7
GND
Ground
8
VO-
Unspecified
Thermal Pad
EP
Ground
Thermal pad; connect to GND

TPA2005D1DRBR