Part Audit


I’ll audit the part metadata, locate the official ST datasheet if needed, compare symbol/footprint/pins against it, update the Datasheet property, and document any discrepancies.
The project is a three-terminal part definition rather than a normal placed component. I’m now checking its footprint and project-level metadata before comparing it to the manufacturer drawing.
I’m checking the package geometry, pad numbering, and hidden project properties in parallel.
The footprint currently identifies itself as STPS10L40CSF/PSMC (TO-277A) while the project MPN is STPS10M60SF; I’m verifying whether that is a harmless family reuse or a real mismatch.
Created a project doc

Part Audit

View Document

Part Audit Identity and existing properties Datasheet key specifications
  • Device: single low-drop power Schottky rectifier
  • Package: PSMC (TO-277A), 90 mg, tape-and-reel base quantity 6000
  • Marking: PS10M60
  • Repetitive peak reverse voltage, VRRM: 60 V
  • Average forward current, IF(AV): 10 A at Tc = 145 °C, 50% square-wave duty
  • Non-repetitive surge current, IFSM: 230 A, 10 ms sinusoidal pulse
  • Maximum junction temperature: 175 °C
  • Maximum forward voltage: 0.56 V at 5 A and 25 °C; 0.65 V at 10 A and 25 °C
  • Maximum reverse leakage at VRRM: 50 µA at 25 °C; 25 mA at 125 °C (8 mA typical)
  • Features: low profile (1.1 mm typical), wettable flanks, avalanche capability, ECOPACK2 compliance
Pin and symbol cross-check
Audit complete. The official ST datasheet URL was already set, and the 3-pin mapping and TO-277A land pattern match; issues are missing package/pin metadata, an ambiguous description, and a footprint filename referencing STPS10L40CSF.
Full specs and findings: Part Audit.
Clean up part metadata
Rename footprint asset
Review 3D alignment

Name
Pin #
Type
Part Type
Terminal Order
A
1
Unspecified
Terminal
A
2
Unspecified
Terminal
K
3
Unspecified
Terminal

STPS10M60SF