1/4 Inspect all available part metadata, symbol, footprint, and pins

Inspect all available part metadata, symbol, footprint, and pins

Find and verify the official datasheet; update Datasheet property if absent

Cross-check package, pinout, symbol, footprint, and descriptions

Document key specifications and mismatches

Thought for 12 sec
Thought for 9 sec
Awaiting 1 background task
Received notification from "IRM-30 Datasheet Audit" that it finished — picking the work back up.
The audit executor has finished. I’m reconciling its findings, independently verifying the saved datasheet property and reported mismatches, then I’ll publish the concise review.
Audit complete. The official Mean Well datasheet was added and verified; the four-pin footprint geometry and numbering match the datasheet.
  • Critical mismatch: IRM-30 is a series, not an exact MPN; output voltage/current remain undefined. Select IRM-30-5, -12, -15, -24, or -48.
  • Missing metadata: manufacturer, part type, package, pin types, and pin descriptions.
  • The footprint is named IRM-30-5, which may incorrectly imply the 5 V variant.
  • A Flux part-quality report was filed.
Full specifications, pin mapping, mechanical checks, and mismatch severities are in Part Datasheet Audit.
Select exact IRM variant
Compare output variants
Improve footprint clearance

V-
Pin Number
4
V+
Pin Number
3
AC/L
Pin Number
1
AC/N
Pin Number
2
Part Datasheet Audit
Scope and result
Part/project: IRM-30
Flux part UID: 8db70966-3aec-4dee-82cc-bd5057bd86d0
Audit date: 2026-08-21
Result: Datasheet property populated and re-read successfully. The official source used was the current Mean Well IRM-30 series PDF.
Datasheet
  • Official manufacturer PDF: https://www.meanwell.com/Upload/PDF/IRM-30/IRM-30-SPEC.PDF
  • Manufacturer product page: https://www.meanwell.com/webapp/product/search.aspx?prod=IRM-30
  • Datasheet identification: IRM-30-SPEC, revision dated 2026-04-03.
  • Variant coverage: IRM-30-5, IRM-30-12, IRM-30-15, IRM-30-24, and IRM-30-48; blank suffix after the voltage denotes PCB mounting, while ST denotes screw-terminal mounting.
  • Persisted property after mutation: https://storage.googleapis.com/graviton-electric-symbols/document_assets/user-uploaded/518ae98b1f05bb284f5bbe1be490ea30f0f611230844b609d296895452ab3127.pdf. Flux ingested/canonicalized the official Mean Well URL into this managed PDF asset. The source submitted for the mutation was the official URL above, not a distributor mirror.
Inspected project metadata

Table


ItemActual project valueDatasheet/audit finding
NameIRM-30Series name, not a complete orderable model
DescriptionIRM-30Too generic to identify output voltage or mounting variant
Manufacturer Part NumberIRM-30Incomplete: official orderable PCB models require -5, -12, -15, -24, or -48
Manufacturer NameEmptyExpected MEAN WELL / Mean Well
Part TypeEmptyExpected AC-DC encapsulated PCB-mount power-supply module
Designator PrefixUValid syntactically, but PS is more semantically appropriate for a power supply
Package/case propertyNot populatedDatasheet case is IRM30, PCB-mount body 69.5 × 39 × 24 mm
Terminal count4Correct for PCB-mount IRM-30
Datasheet URLWas empty; now populatedOfficial source verified; persisted as a Flux-managed copy
LifecycleNot stated on this projectCurrent manufacturer page lists active voltage variants
Key electrical specifications
Family-wide
  • Function: isolated, encapsulated 30 W AC-DC power module for direct PCB mounting; Class II design with no frame-ground pin.
  • Input: 85–305 Vac, 47–440 Hz.
  • Typical input current: 0.75 A at 115 Vac; 0.5 A at 230 Vac; 0.375 A at 277 Vac.
  • Cold-start inrush: 25 A at 115 Vac; 45 A at 230 Vac.
  • No-load consumption: <0.1 W.
  • Leakage current: <0.25 mA at 277 Vac.
  • Setup/rise time: 1000 ms/30 ms at 230 Vac; 1500 ms/30 ms at 115 Vac, full load.
  • Hold-up time: 40 ms at 230 Vac; 12 ms at 115 Vac, full load.
  • Protections: short circuit, overload (105–160% rated output power, hiccup and auto-recovery), and overvoltage.
  • Isolation: input-to-output withstand 4.2 kVac; insulation resistance 100 MΩ at 500 Vdc, 25 °C, 70% RH.
  • Operating temperature: −30 to +85 °C, subject to derating curve.
  • Cooling: free-air convection.
  • Operating humidity: 20–90% RH non-condensing.
  • Operating altitude: 2000 m; datasheet specifies altitude derating above 2000 m.
  • Warranty: 3 years.
  • PCB-mount vibration: 2 G, 10–500 Hz.
  • Safety/EMC highlights: IEC/UL/EN 62368-1 family approvals, IEC/EN 61558-1/-2-16, Class B conducted/radiated emissions; final equipment still requires EMC re-verification.
Output variants

Table


Exact modelOutputRated currentRated powerTypical efficiencyMax ripple/noiseOVP range
IRM-30-55 V6 A30 W83%120 mVp-p5.25–6.75 V
IRM-30-1212 V2.5 A30 W88%150 mVp-p12.6–16.2 V
IRM-30-1515 V2 A30 W88%200 mVp-p15.75–20.25 V
IRM-30-2424 V1.3 A31.2 W88.5%240 mVp-p25.2–32.4 V
IRM-30-4848 V0.63 A30.2 W90%300 mVp-p50.4–64 V
Voltage tolerance is ±2.5% for all listed variants. Ripple/noise is specified with the datasheet's 20 MHz, 12-inch twisted-pair, 0.1 µF + 47 µF measurement method.
Mechanical and footprint audit
Datasheet facts
  • Case: IRM30, PCB mounting style.
  • Body: 69.5 × 39 × 24 mm (L × W × H), general drawing tolerance ±1 mm.
  • Weight: 0.094 kg.
  • Lead diameter: 1.0 mm.
  • Lead protrusion: 3.5 ±1 mm.
  • Bottom-view lead centers use a 61.5 mm input-to-output X spacing.
  • Input lead spacing: 5.5 mm.
  • Output lead spacing: 9.0 mm.
Project footprint
Footprint asset: IRM-30-5.kicad_mod; model asset: IRM-30_MWU.step.

Table


PadProject nameProject center (mm)Hole / copper diameterExpected functionResult
1AC/L(0, 0)1.0414 / 1.5494 mmAC line inputMatch
2AC/N(0, 5.5)1.0414 / 1.5494 mmAC neutral inputMatch
3V+(61.5, 9.0)1.0414 / 1.5494 mmPositive DC outputMatch (V+ vs datasheet +V is cosmetic)
4V-(61.5, 0)1.0414 / 1.5494 mmNegative DC output/returnMatch (V- vs datasheet -V is cosmetic)
  • Fab outline measures approximately 69.4944 × 38.989 mm, effectively matching 69.5 × 39 mm.
  • Courtyard measures approximately 70.0024 × 39.497 mm.
  • Pad center geometry exactly follows 5.5 mm, 9.0 mm, and 61.5 mm datasheet spacings.
  • The 1.0414 mm drill is only 0.0414 mm larger than the nominal 1.0 mm lead. The datasheet does not provide a recommended finished-hole diameter or tolerance for the lead diameter, so solderability/manufacturing allowance cannot be fully validated from the official sheet alone. This is an ambiguity, not a proven geometric mismatch.
  • The footprint filename explicitly says IRM-30-5, but the mechanical package is shared by all PCB-mount output-voltage variants.
Complete pin mapping and symbol audit

Table


PinDatasheet name/functionProject terminalActual Pin TypeActual Pin DescriptionAssessment
1AC/L — AC line inputAC/LUnspecifiedMissingNumber/name match; metadata incomplete
2AC/N — AC neutral inputAC/NUnspecifiedMissingNumber/name match; metadata incomplete
3+V — positive regulated DC outputV+UnspecifiedMissingNumber/function match; name order cosmetic
4−V — negative DC output/returnV-UnspecifiedMissingNumber/function match; name order cosmetic
The schematic symbol is implemented as four separated terminal objects rather than a conventional enclosed power-module body. Pin numbers are stored as terminal properties and map correctly. No nets exist. Symbol pin positions place AC inputs on the left and DC outputs on the right, preserving functional direction, but all terminal electrical types are Unspecified and all descriptions are absent.
Mismatches and ambiguities

Table


SeverityFindingExpectedActual
SevereMPN/variant is not uniquely identifiedOne exact orderable model: IRM-30-5/-12/-15/-24/-48IRM-30, which is the series name only
SevereElectrical output is therefore undefinedExact output voltage/current/power must follow selected suffixNo suffix or output property; cannot know which variant the part represents
HighInternal footprint naming biases toward the 5 V modelFootprint asset should be neutral or match exact selected MPNIRM-30-5.kicad_mod while root MPN is only IRM-30
MediumManufacturer missingMean WellEmpty
MediumPart type missingAC-DC power-supply module / power sourceEmpty
MediumPackage/case property missingIRM30; PCB mount; 69.5 × 39 × 24 mmEmpty
MediumTerminal electrical types missingAC pins = power inputs; +V/−V = power output/return as appropriate for ERCAll Unspecified
MediumTerminal descriptions missingFunctional descriptions from datasheetEmpty
MediumDrill margin is not authoritatively validatedRecommended finished-hole size or adequate tolerance allowance1.0414 mm hole for nominal 1.0 mm lead; datasheet gives no hole recommendation/lead tolerance
LowDescription is non-informativeManufacturer, power, topology, input, exact output, mountingIRM-30
LowDesignator prefix is generic IC stylePrefer PS for a power supplyU
LowOutput terminal names reversed typographically+V, -VV+, V-; semantics unchanged
LowFootprint silkscreen value is non-standardExact MPN or neutral series markingIRM-30_MWU
Verification evidence
  • Re-read of project properties confirms a non-empty Datasheet URL persisted after mutation.
  • Footprint tree inspection confirmed four numbered through-hole pads and the exact coordinates/diameters listed above.
  • Component review was run after the update. It reports two remaining warnings: Manufacturer Name is not set and Part Type is not set. No datasheet-missing warning remains.
  • Symbol and footprint geometry were not altered.
If the lead decides the incomplete MPN/variant identity and IRM-30-5 footprint naming constitute a severe reusable library-part quality issue, use this Flux part/project link:
The principal escalation statement should be: the published part uses a series-level MPN (IRM-30) despite the official manufacturer offering five electrically different output variants, while its footprint asset is specifically named IRM-30-5; manufacturer, part type, package metadata, terminal types, and terminal descriptions are also missing.
  • Scope and result

  • Datasheet

  • Inspected project metadata

  • Key electrical specifications

  • Family-wide

  • Output variants

  • Mechanical and footprint audit

  • Datasheet facts

  • Project footprint

  • Complete pin mapping and symbol audit

  • Mismatches and ambiguities

  • Verification evidence

  • Part-quality escalation link