Part Datasheet Review
Pin Description and Pin Type metadata should be filled in.G6S-2-5VDChttps://www.ecb.omron.com.cn/product-detail?partId=19056 returned an Omron China 404 page, so the project Datasheet URL was updated to the official Omron PDF.G6S-2-5VDCOmronKRelayThrough Hole7354e086-d565-4078-b2db-17377dd072f91, 3, 4, 5, 8, 9, 10, 12G6S-2 with 5 VDC coil optionTable
| Project terminal | Pin number | Datasheet function | Result |
|---|---|---|---|
| COIL_+ | 1 | Coil + | Match |
| COIL_- | 12 | Coil - | Match |
| NC_1 | 3 | Pole 1 NC | Match |
| COM_1 | 4 | Pole 1 common | Match |
| NO_1 | 5 | Pole 1 NO | Match |
| NC_2 | 10 | Pole 2 NC | Match |
| COM_2 | 9 | Pole 2 common | Match |
| NO_2 | 8 | Pole 2 NO | Match |
G6S2DC3.kicad_mod was inspected. Its pad pattern matches the datasheet G6S-2 through-hole mounting pattern:1, 3, 4, 5 on one row and 12, 10, 9, 8 on the opposite row.G6S-2-5VDC, the part should be described as a through-hole / PCB-terminal DPDT relay. Related G6S variants such as G6S-2F and G6S-2G are surface-mount, but this specific footprint is not.COIL_+, COIL_-, NC_1, etc.), but the individual terminal properties do not include explicit Pin Description values and all inspected terminal Pin Type values are Unspecified. This is not a pinout error, but it weakens library documentation and ERC quality.G6S-2 mechanical drawing in the datasheet is the PCB through-hole terminal version with eight 1.0 mm holes. The project should prioritize the model-specific mechanical section over the family title.G6S-2-5VDC / G6S-2 DC5. The main corrections recommended are metadata/documentation improvements: change the project description from surface-mount to through-hole and add explicit pin descriptions/types for all terminals.Source Reviewed
Existing Project Metadata Reviewed
Datasheet Key Specs
Pinout Cross-Check
Footprint Cross-Check
Mismatches / Issues Flagged
Overall Result