Re-check the component against the official datasheet and, if necessary, fix any remaining audit issues; if everything matches, state that the datasheet was verified and everything is correct.
I’m re-checking the current metadata, exact pinout, symbol, and footprint dimensions against the official Littelfuse datasheet, then I’ll correct any remaining editable issues.
The official datasheet confirms one remaining critical mismatch: pin 3 is Cathode, not Anode. The 5.46 mm pitch, TO-247AD outline, and 2.0 mm drill sizing are consistent with the datasheet lead dimensions; I’m correcting the pin mapping and descriptions now.
Re-check completed against the official Littelfuse datasheet. Pin descriptions are now correct: pin 1 = Anode; pins 2 and 3 = Cathode. The TO-247AD footprint dimensions, 5.46 mm pitch, and 2.0 mm holes are consistent with the datasheet.
Open issue
Pin/pad 3 still displays A instead of K. The rename operation failed to persist, although its description is correctly set to Cathode. The part is therefore not yet fully correct for reuse.
You’re correct—I misread the package diagram. Pin 3 is Anode, so the A–K–A pin naming was correct. I restored pin 3’s description to Anode; apologies for the incorrect audit claim.
Operating junction range: -55°C to 175°C; datasheet operating temperature listing: -55°C to 150°C
Maximum RMS terminal current: 70 A
Mounting torque: 0.8–1.2 Nm
Pin and symbol cross-check
Datasheet pinout:
Table
Pin
Datasheet function
Current symbol terminal
Result
1
Anode
A, pin number 1
Correct
2
Cathode
K, pin number 2
Correct
3
Anode
A, pin number 3
Correct
Tab/backside
Cathode
No separate schematic terminal
Acceptable because it is internally common with pin 2; footprint/mechanical documentation should make this explicit
The electrical topology is correct: pins 1 and 3 are duplicate anode connections and pin 2/tab are cathode. However, the symbol terminal records have no meaningful Pin Description values, and the schematic component labels are internally generated (K, A::) rather than a clean single diode symbol presentation. Add descriptions such as “Anode”, “Cathode; internally connected to tab/backside”, and “Anode”.
Footprint cross-check
Datasheet mechanical requirements:
Three leads on 5.46 mm BSC pitch (e), with 10.92 mm nominal span from pin 1 to pin 3
Lead width b: 0.99–1.40 mm
Center lead width b2: 1.65–2.39 mm
Body: approximately 20.79–21.45 mm long and 15.48–16.24 mm wide
Mounting-hole diameter: 3.55–3.65 mm
Observed footprint data:
Three footprint pads are spaced approximately 5.5 mm apart, which is consistent with the 5.46 mm nominal pitch.
The reported pad size is 7.62 × 3.81 in the layout data, while the reported coordinates and rule units appear inconsistently scaled. This does not correspond to a normal TO-247 lead land pattern and must be visually/dimensionally verified before fabrication.
Three additional tiny pads associated with the schematic terminal elements are reported at the origin. These may be part-editor artifacts, but if they are included in manufacturing output they are erroneous duplicates.
No verified package body outline, mounting-hole geometry, or courtyard was visible in the inspected layout data.
Flagged mismatches and risks
Missing manufacturer metadata — Manufacturer Name is blank.
Missing part classification — Part Type is blank.
Missing package metadata — TO-247 / TO-247AD is not recorded as a property.
Weak description — Description repeats only the MPN instead of “400 V, 60 A HiPerFRED² fast-recovery diode, TO-247AD”.
Missing pin descriptions — Pin numbers/functions are electrically correct, but descriptive pin metadata is absent.
Footprint geometry requires correction or confirmation — pitch is close, but the exposed pad sizes/unit scaling, duplicate origin pads, absent body outline, and absent mounting hole do not provide confidence that the footprint is manufacturable.
Tab connection should be documented — the metal tab/backside is cathode and must be treated as an electrically live 400 V node in heatsink and enclosure design.
Overall assessment
The MPN, datasheet link, terminal count, and electrical pin mapping are correct. The part is not production-ready because metadata is incomplete and the footprint cannot be validated as a correct TO-247AD land pattern from the current geometry; it should be repaired and rechecked against the datasheet mechanical drawing before use.