Datasheet Review and Verification

I’ll review the part metadata and existing symbol/footprint, find the official datasheet if missing, update the Datasheet property, then cross-check pins and summarize mismatches.
I found the official Tensility product page and PDF datasheet; I’ll add the datasheet URL and finish the mechanical/pin review now.
Completed the Tensility 54-00248 review and created the report: Part Datasheet Cross-Check: Tensility 54-00248.
Open items:
  • I recorded the official datasheet URL in Implementation Details because the available project-property editor did not expose a dedicated Datasheet URL field.
  • Main issues flagged: missing pin descriptions, sparse part metadata, and a footprint unit-display caution to verify before manufacturing.
Suggested next steps:
  1. Add generic pin descriptions for pins 1–8 and S1.
  2. Populate searchable part metadata like manufacturer, connector type, current/voltage rating, and contact count.
  3. Run/export a manufacturing drill/pad check to confirm the footprint dimensions.
Fix metadata and verify
Add pin descriptions
Populate part metadata
Verify footprint export
Check official PDF visually

Refine this doc
Ask about this doc
Part Datasheet Cross-Check: Tensility 54-00248
Reviewed project part information
  • Project/part name: 54-00248
  • Manufacturer Part Number: 54-00248
  • Manufacturer: Tensility International Corporation (from official product page)
  • Published Flux part UID: eab7c779-cc18-4da4-922b-5393d7f44100
  • Existing project description: A1 Manufacturer Recommendations 16mm Tensility
  • Existing project-level properties before review: Manufacturer Part Number: 54-00248, Designator Prefix: J
  • Datasheet URL added under project Implementation Details: https://tensility.s3.us-west-2.amazonaws.com/uploads/pdffiles/54-00248.pdf
  • Official product page: https://www.tensility.com/products/54-00248
Note: Flux project properties available to the mutation tool did not expose a dedicated Datasheet URL project-level field, so the official datasheet URL was recorded in Implementation Details.
Official key specs from Tensility
  • Description: Connector, M12 A-code socket, 8 pin, 12 × L23.4 mm, panel mount, thru hole, 90°, board lock, gold plated, IP67.
  • Connector family/type: M series, M12.
  • Style/gender: jack/socket, female socket contacts.
  • Coding: A-code.
  • Contact count: 8 signal contacts.
  • Shield: shielded shell contact shown.
  • Mounting/package style: rear panel mount, right-angle PCB thru-hole, board-lock mechanical retention.
  • Voltage rating: 30 V.
  • Current rating: 2.0 A.
  • Operating temperature: -40 to +105 °C.
  • Mating cycles: 500 minimum.
  • Environmental rating: IP67 in mated state; panel ingress requires sealing cap per datasheet note.
  • Materials: PA66 insulator, brass/gold-plated pins, brass/nickel-plated shell, silicone rubber O-ring.
  • Electrical test specs: dielectric strength 500 Vac for 1 minute; insulation resistance 100 MΩ at 500 Vdc; contact resistance listed as 10 MΩ or less in the extracted datasheet text, likely intended as 10 mΩ or less but should be verified visually in the PDF.
Schematic symbol cross-check
Current symbol terminals
The Flux part currently contains 9 schematic terminal components:

Table


Symbol terminalPin Number propertyPin TypeNotes
11PassivePresent
22PassivePresent
33PassivePresent
44PassivePresent
55PassivePresent
66PassivePresent
77PassivePresent
88PassivePresent
SHELLS1PassivePresent; shield/shell terminal
Symbol result
  • Contact count matches the datasheet: 8 signal contacts plus shell/shield.
  • Pin numbering matches the datasheet-level contact numbering: 1 through 8 plus shell.
  • Pin electrical type is acceptable as Passive for a connector.
  • Mismatch / incomplete metadata: individual terminals have no Pin Description text. Datasheet does not provide signal functions, so recommended descriptions are generic contact labels such as M12 A-code contact 1 through M12 A-code contact 8, and Shield / shell for S1.
  • Mismatch / metadata gap: project-level properties do not currently include manufacturer name, connector type, contact count, package/mounting style, voltage/current ratings as part-specific searchable properties except the voltage/temperature entries added during this review.
Footprint cross-check
Current footprint details found
The imported KiCad footprint TENSILITY_54-00248.kicad_mod contains:
  • Signal/contact plated thru-hole pads:
    • Pin 1 at (-1.5, -2.1), 1.4 mm pad, 1.0 mm drill, rectangular.
    • Pin 2 at (1.5, -2.1), 1.4 mm pad, 1.0 mm drill.
    • Pin 3 at (2.725, 0.0), 1.4 mm pad, 1.0 mm drill.
    • Pin 4 at (2.075, 2.1), 1.4 mm pad, 1.0 mm drill.
    • Pin 5 at (0.0, 2.1), 1.4 mm pad, 1.0 mm drill.
    • Pin 6 at (-2.075, 2.1), 1.4 mm pad, 1.0 mm drill.
    • Pin 7 at (-2.725, 0.0), 1.4 mm pad, 1.0 mm drill.
    • Pin 8 at (0.0, 0.0), 1.4 mm pad, 1.0 mm drill.
  • Shell plated thru-hole pad:
    • S1 at (0.0, 4.0), 1.7 mm pad, 1.3 mm drill.
  • Mechanical NPTH board-lock holes:
    • Four unnumbered NPTH holes at (±7.5, 0.0) diameter 2.3 mm and (±7.5, 4.0) diameter 2.8 mm.
  • Footprint outline includes panel edge marking, fab/silk geometry, courtyard, and pin 1 marker.
Footprint result
  • Signal pad count matches the datasheet: 8 × Ø1.0 mm through-holes.
  • Shell pad is present and matches the datasheet concept of a shield/shell connection.
  • Board-lock/mechanical holes are present and match the expected four unconnected mechanical holes.
  • Pad coordinates are consistent with the datasheet dimensions extracted for 2.1 mm vertical spacing, 4.15/5.45 mm horizontal spread references, and 16 mm board-lock spacing.
  • The footprint appears imported in meters internally in the layout tree, but the KiCad asset payload is in millimeters and is the authoritative footprint source in this part.
  • Mismatch / caution: the current layout tree reports computed pad positions such as x: 0.0015 and sizes such as 0.0014 under unit: mm; this appears to be unit-scaled display data from the importer, while the embedded KiCad footprint payload correctly shows mm dimensions. Verify generated manufacturing output before release.
  • Mismatch / caution: the NPTH pads are named None; this is acceptable for unconnected mechanical holes, but if the platform expects unique mechanical pad names, rename them or ensure DRC/export handles them correctly.
  1. Datasheet URL was missing as a dedicated part property.
    • Action taken: recorded official datasheet URL in project Implementation Details because the available project-property mutation interface did not expose a dedicated Datasheet URL property.
    • Recommended follow-up: if Flux exposes the published-part Datasheet URL field in the part editor UI, set it there as https://tensility.s3.us-west-2.amazonaws.com/uploads/pdffiles/54-00248.pdf or the product-page PDF link https://tensility.s3.us-west-2.amazonaws.com/imports/product_spec_sheets/54-00248.pdf.
  2. Pin descriptions are missing.
    • Recommended follow-up: add Pin Description values: pins 1–8 as M12 A-code contact N; S1 as Shield / shell.
  3. Part metadata is sparse.
    • Recommended follow-up: add searchable component/part metadata where supported: Manufacturer Name = Tensility International Corporation; Connector Type = M12 A-code socket; Connector Gender = Socket / female; Connector Positions = 8; Mount = Through Hole / Panel Mount; Package = right-angle panel-mount circular connector; Current Rating = 2 A; Voltage Rating = 30 V; Operating Temperature = -40 to 105 °C; IP rating = IP67 if supported.
  4. Contact resistance extraction ambiguity.
    • The web/PDF extraction returned 10 MΩ or less, which is unusual for contact resistance and likely means 10 mΩ or less. Verify visually against the official PDF before entering that spec as a property.
  5. Footprint unit-display caution.
    • Embedded KiCad footprint dimensions are correct-looking in mm, but Flux layout tree displayed small decimal meter-like values while labeling unit as mm. Exported drill/pad data should be checked before manufacturing.
Overall conclusion
The core symbol and footprint structure match Tensility 54-00248: 8 numbered connector contacts, one shell/shield pad, right-angle through-hole footprint, and board-lock mechanical holes. The main gaps are metadata completeness, missing pin descriptions, and the need to set the official datasheet URL in the dedicated published-part datasheet field if the UI/tooling exposes it.
  • Reviewed project part information

  • Official key specs from Tensility

  • Schematic symbol cross-check

  • Current symbol terminals

  • Symbol result

  • Footprint cross-check

  • Current footprint details found

  • Footprint result

  • Flagged mismatches and recommended fixes

  • Overall conclusion

Documents

  • Part Datasheet Cross-Check: Tensility 54-00248

Assets

54-00248

54-00248

54-00248 Symbol.svgDefault
kicad_mod

54-00248

TENSILITY_54-00248.kicad_modFootprint
step

54-00248

54-00248.step3D Model
image.png

image.png

imageThumbnail

54-00248

54-00248 thumbnail
A1 Manufacturer Recommendations 16mm Tensility

Properties

-40 to 105 °C

Datasheet URL: https://tensility.s3.us-west-2.amazonaws.com/uploads/pdffiles/54-00248.pdf

30

V

54-00248

Tensility International Corp

Connector

J

parametric-v1

Pricing & Availability

See prices from popular manufacturers for your project.

Controls