Part Audit Review


Review all available part information (MPN, package, pin count, description, properties). If no datasheet URL is already set, search the web for the official datasheet and update the part's Datasheet property with the URL. Then cross-check the schematic symbol, footprint, and pin descriptions against the datasheet. Summarize key specs and flag any mismatches.
I’ll audit the part metadata, locate the official TE Connectivity datasheet if needed, update the Datasheet property, then verify the symbol pins and footprint against the manufacturer documentation.
Created a project doc

Part Audit Report

View Document

Part Audit Report Identification
Audit complete. The existing official TE datasheet URL was already populated; symbol numbering and footprint geometry match the RT2 datasheet. I corrected all eight terminals from Unspecified to Passive and added functional pin descriptions.
Minor metadata issues remain: no explicit Package property, vague Mount: Standard, broad part type, and disabled main silkscreen. Full specifications and comparisons are in Part Audit Report.
Fix metadata and silk
Correct package metadata
Improve part description
Restore silkscreen

Name
Pin #
Type
Section
Pin Group
Orientation
Order
Sub-symbol
Pin Description
COM_1
11
Passive
Pole 1 common contact (terminal 11).
NC_1
12
Passive
Pole 1 normally-closed contact (terminal 12).
NO_1
14
Passive
Pole 1 normally-open contact (terminal 14).
COM_2
21
Passive
Pole 2 common contact (terminal 21).
NC_2
22
Passive
Pole 2 normally-closed contact (terminal 22).
NO_2
24
Passive
Pole 2 normally-open contact (terminal 24).
COIL_1
A1
Passive
Coil terminal A1; 230 VAC, 50 Hz coil connection.
COIL_2
A2
Passive
Coil terminal A2; 230 VAC, 50 Hz coil connection.

1-1393243-8