Termostato Wi-Fi con NodeMCU
1:20
Checking if I can make the changes for you.
Considering net designators.
Table
| Net | Connections |
|---|---|
| R4:P1, R3:P2, U1:25, U3:EN, C2:P1, D2:K, D1:K, U1:VIN, U3:VIN, K1:A1, C1:P1, R5:P1, C4:P1, U1:EN, U4:4, C5:P1, U2:VDD, U3:VOUT, C6:P1, C3:P1, U1:11, Q1:B, U1:16 | |
| PSU_5V_RAW | PS1:+VO, D2:A |
| U1:D5 GPIO14, R2:P1, R2:P2, U4:1, GND:GND, R4:P2, R5:P2, PS1:-VO, C3:P2, U1:24, C6:P2, U2:GND, C4:P2, C2:P2, U1:10, Q1:E, U4:2, C5:P2, U3:GND, U1:14, R1:P2, C1:P2 | |
| ONEWIRE_TEMP | U1:D2 GPIO4 SDA, R1:P1, U2:DQ |
| K1:A2, D1:A, Q1:C | |
| Net 5 | C7:P2, R6:P2 |
| RELAY_COM | C7:P1, K1:COM |
| U4:3, R3:P1 | |
| RELAY_NO | K1:NO, R6:P1 |
Updated 9 connections
0:48
Connected R4:P1, R3:P2, U1:25, U3:EN, C2:P1, D2:K, D1:K, U1:VIN, U3:VIN, K1:A1, C1:P1, R5:P1, C4:P1, U1:EN, U4:~, C5:P1, U2:VDD, U3:VOUT, C6:P1, C3:P1, U1:11, Q1:B, U1:16 to ^Net 1
Connected PS1:+VO, D2:A to ^PSU_5V_RAW
Connected U1:D5 GPIO14, R2:P1, R2:P2, U4:~, R4:P2, R5:P2, PS1:-VO, C3:P2, U1:24, C6:P2, U2:GND, C4:P2, C2:P2, U1:10, Q1:E, U4:~, C5:P2, U3:GND, U1:14, R1:P2, C1:P2 to ^GND
Connected U1:D2 GPIO4 SDA, R1:P1, U2:DQ to ^ONEWIRE_TEMP
Connected K1:A2, D1:A, Q1:C to ^Net 2
Connected C7:P2, R6:P2 to ^Net 5
Connected C7:P1, K1:COM to ^RELAY_COM
Connected U4:~, R3:P1 to ^Net 3
Connected K1:NO, R6:P1 to ^RELAY_NO
1:10
Analyzing the schematic.
Considering a potential fix.
Checking if I can make the changes for you.
Net Connections to be added
| Net | Connections |
|---|---|
| U1:D5 GPIO14, R2:P1 | |
| R2:P2, U4:1 |
Net Connections to be removed
| Net | Connections |
|---|---|
| R2:P1, R2:P2 |
No changes applied.
0:46
Plan completed.
Reviews
Termostato WiFi da Incasso 230Vac NodeMCU
Properties
230 Vac 50 Hz input, mains section separated from LV logic and clearly labeled L and N
Wi-Fi
flowchart TD subgraph HV [HV Zone 230Vac] J_AC[AC input terminals] PS1[HLK 5V AC DC] K1[Relay SPDT contacts] end subgraph BARRIER [Safety Barrier] U4[PC817 optocoupler] ISO[6mm isolation boundary] end subgraph LV [LV Zone 5V 3V3] U3[AP2112K 3V3] U1[NodeMCU ESP8266] U2[DS18B20] Q1[2N2222A driver] end J_AC --> PS1 PS1 --> U3 U3 --> U1 U1 --> U2 U1 --> U4 U4 --> Q1 Q1 --> K1
NodeMCU web server with hysteresis control 0.5 K
Dry contact SPDT relay interface, isolated from LV control, target compatibility 5(3) A at 250 Vac
230 Vac, 50 Hz
HVAC thermostat
Prototype
HV/LV split for 230 Vac thermostat; maintain 6 mm minimum creepage and clearance between mains and low voltage; prefer PCB slot barrier between zones
Continuous thermostat duty for residential boiler control
Proto
230 Vac input, isolated 5 V and regulated 3.3 V rails
Web page thermostat UI
IEC 62368-1 oriented zoning, HV/LV separation 6mm minimum
Pricing & Availability
Distributor | Qty 1 |
|---|---|
Arrow | $0.47–$3.46 |
Digi-Key | $3.87–$8.64 |
LCSC | $3.83–$4.91 |
Mouser | $0.79–$3.50 |
TME | $0.84–$1.54 |
Verical | $0.10–$6.30 |
Controls
Welcome 👋
Flux helps you build PCBs faster with an AI teammate!
Create your account to collaborate, stay updated, fork your own version, and get instant answers from our AI agent.