oscar999ml / Empty Tan Transporter

Loaded

0

0

Files

Schematic

PCB

Log InSign Up

Chat

Welcome to Flux

Treat Flux like your intern. Tell it what you'd like to build and it'll get to work. You can also ask it questions, brainstorm ideas, and teach it your preferences. Learn More

Design a blinking LED circuit
Design a WiFi water flow meter
Help me brainstorm ideas
Design a block diagram
Find parts in the library
Read a datasheet
Simulate a circuit
New Subsystem Wizard

​
Sign up to send
tengo una pregunta ayudame.... actualmente tengo 2 pulsadores en pull up con res...

oscar999ml

oscar999ml

@copilot tengo una pregunta ayudame.... actualmente tengo 2 pulsadores en pull up con resistencias de 1k ohm y funciona correctamente, creo. tengo que remplasar los pulsadores por 2 sensores:
Image

Image

https://cdn2.flux.ai/flux-comment-files/files/commentFileId-8a1febfcc092d391a9d230bea57e83ebab0aadf2574c646eb8d9178632e140e0.jpeg?GoogleAccessId=graviton-mvp%40appspot.gserviceaccount.com&Expires=4863215793&Signature=CgSWOAT01rseZ9xKueAFP9R24NcjdvPrN%2F7JRHJaGaxV%2FTsymoZBfYaM1aECZ6ZUU5ULNmeGWiUfDz0Yt2wtT8z2Sl9imtw0CRHf4aXeI9RksEAXSqLcmNFOvR9UnH4ZmR4EwLV8g1Y6gCzyTjdt4mm9taXq81jwzXaztdrvl8d%2Bq6ttfXfKFWsU8ySv5IH8oE03kh5gOPYPH%2FvLToDtRrtS3VmKCNc9bc6qZQJqk1DOayfKSMOjRAbwXCmUKqT1vKbndaFHWkExRafXR6UkMa%2FFCO8TiY3PtEFRArwl%2BOS6%2BD0q8LPVZ1rNugvSG431Cnw2T8N5NLKmJA7QyoVqEw%3D%3D pero la economia no me lo permitio entonses decidi colocar 3 cable que imuln los 3 sensores al agua le puse sal para mayor contacto y los 3 cables no funcionan me entregan nnumeor logicos incredecibles. que estoy haciendo mal.
2y

copilot

Entiendo tu situación. Al intentar usar cables en agua salada como un sustituto para sensores, debes tener en cuenta que el agua salada crea un entorno conductivo que puede ser bastante inconsistente en términos de resistividad y por ende en la señal eléctrica generada. Esto puede hacer que las lecturas sean impredecibles si la configuración no está bien controlada. Aquí hay algunas sugerencias para enfrentar este problema:
  • Estabilizar el entorno: Asegúrate de que la concentración de sal en el agua sea uniforme y de que los cables sean colocados a una distancia consistente entre ellos para minimizar las variaciones en la conductancia.
  • Usar un voltaje de referencia: Si aun no estas haciéndolo, usa un divisor de voltaje o una salida de voltaje fija para establecer un punto de referencia claro para cuando el agua sea y no sea conductiva.
  • Filtrado de señal: Considera añadir algún tipo de filtrado de hardware, como un capacitor en paralelo con la salida del sensor para suavizar el ruido, o usa filtrado de software para descartar lecturas espurias.
  • Ajustar los umbrales digital: En el software, ajusta los umbrales para el voltaje o la resistencia que consideras una lectura "activada" para manejar mejor la variabilidad.
Podrías indicarme más detalles sobre cómo estás configurando exactamente tus cables y cómo los estás conectando a tu circuito. Con esa información, podría darte consejos más específicos para mejorar tus resultados.
2y
oscar999ml

oscar999ml

Image

Image

https://cdn2.flux.ai/flux-comment-files/files/commentFileId-27bfb1e94821ae43ac925e2bd663855d98c8277268eaa506982e6df758634f3b.png?GoogleAccessId=graviton-mvp%40appspot.gserviceaccount.com&Expires=4863216171&Signature=zThKJ3kljOuGmM9455gvxuN86UIi2Q%2FMD0OWfG3AtJexTaSuzxsK%2BZJwHr%2FH9AUOaSanLNjyIYQPu43nL0TrEgJXpme5ACD0oyjpke7yqutZwpxlyeWSTu1KTRaa11e9LrDIGmgDN68p2k%2FYqEVQJto89wCsarfeZDbTNyXU%2BtLQLFzbPAEan2dipazmYNLXXtB39p%2Bjf662OG%2Fc8BhzFJO4zJXJBQFhi2%2Beka6DrIPAuv773SxqOyyvoN2smPU01r08fohRmW1uuaGLwRMSW6PJFhst6G%2F7xjF83zwX%2Fz%2Fs%2Flk9O1WyGtkuqTICrsAD5zyRZ6i41xA3h1rEQDps2g%3D%3D esa es la configuracion y en las entradas logicas, "logictate se llama en proteus" es para simular pull up y jale 3 cables para remplasar el boton y que actuen como sensores normamente serrados en el agua
2y

copilot

Gracias por la información adicional. Por lo que entiendo, tienes configurado un circuito en Proteus utilizando lógica TTL con buffer inversores (74LS04) y un controlador de motores (ULN2803) para manejar una salida, que supongo es un motor representado aquí por un ventilador. Estás intentando sustituir las entradas lógicas por unos cables en agua salada para actuar como sensores.
Primero, considera lo siguiente cuando quieras simular un interruptor usando agua salada y cables:
  1. Consistencia de la conexión: La concentración de sal y la inmersión de los cables deben ser consistentes para obtener una baja resistencia a través del agua y activar la entrada lógica correctamente.
  2. La resistencia interna de las entradas: La resistencia pull-up en las entradas de los buffer inversores (74LS04) podría no ser suficiente para mantener las entradas en un estado alto (1 lógico) de manera confiable cuando los cables no están sumergidos.
  3. Corrosión y desgaste: La corrosión debido al uso de agua salada puede ser un problema y causar conexiones erráticas con el tiempo.
Para mejorar tu configuración, podrías hacer lo siguiente:
  • Usa una resistencia pull-up más alta (como 10k ohms) en las entradas lógicas para evitar falsos positivos debido a la variabilidad en la conductividad del agua salada.
  • Implementa un circuito de acondicionamiento de señal con resistencias y condensadores para filtrar el ruido y estabilizar la detección de los cables en el agua.
  • Considera reemplazar tu configuración casera con sensores de conductividad de agua que están diseñados para entregar lecturas estables en aplicaciones donde la presencia de agua salada se utiliza como un interruptor.
Si tu presupuesto es limitado, experimenta con diferentes distancias entre los cables y concentraciones de sal para obtener la conductividad más estable posible. Es importante que al intentar este enfoque, seas consciente de que el agua y la electrónica pueden ser una combinación peligrosa si no se maneja con precaución, especialmente en relación con las conexiones eléctricas y el riesgo de cortocircuito.
2y
3

Reviews



  • Ground
    Ground
    A common return path for electric current. Commonly known as ground.
    jharwinbarrozo
    20.5M
  • Net Portal
    Net Portal
    Wirelessly connects nets on schematic. Used to organize schematics and separate functional blocks. To wirelessly connect net portals, give them same designator. #portal
    jharwinbarrozo
    43.0M
  • Power Net Portal
    Power Net Portal
    Wirelessly connects power nets on schematic. Identical to the net portal, but with a power symbol. Used to organize schematics and separate functional blocks. To wirelessly connect power net portals, give them the same designator. #portal #power
    jharwinbarrozo
    11.4M
  • Generic Resistor
    Generic Resistor
    A generic fixed resistor ideal for rapid circuit topology development. Its footprint automatically adapts based on the selected package case code—supporting 0402, 0603, 0805, 1203, and many other standard SMD packages, as well as axial horizontal and vertical configurations. Save precious design time by seamlessly add more information to this part (value, footprint, etc.) as it becomes available. Standard resistor values: 1.0 ohm, 10 ohm, 100 ohm, 1.0k ohm, 10k ohm, 100k ohm, 1.0M ohm 1.1 ohm, 11 ohm, 110 ohm, 1.1k ohm, 11k ohm, 110k ohm, 1.1M ohm 1.2 ohm, 12 ohm, 120 ohm, 1.2k ohm, 12k ohm, 120k ohm, 1.2M ohm 1.3 ohm, 13 ohm, 130 ohm, 1.3k ohm, 13k ohm, 130k ohm, 1.3M ohm 1.5 ohm, 15 ohm, 150 ohm, 1.5k ohm, 15k ohm, 150k ohm, 1.5M ohm 1.6 ohm, 16 ohm, 160 ohm, 1.6k ohm, 16k ohm, 160k ohm, 1.6M ohm 1.8 ohm, 18 ohm, 180 ohm, 1.8K ohm, 18k ohm, 180k ohm, 1.8M ohm 2.0 ohm, 20 ohm, 200 ohm, 2.0k ohm, 20k ohm, 200k ohm, 2.0M ohm 2.2 ohm, 22 ohm, 220 ohm, 2.2k ohm, 22k ohm, 220k ohm, 2.2M ohm 2.4 ohm, 24 ohm, 240 ohm, 2.4k ohm, 24k ohm, 240k ohm, 2.4M ohm 2.7 ohm, 27 ohm, 270 ohm, 2.7k ohm, 27k ohm, 270k ohm, 2.7M ohm 3.0 ohm, 30 ohm, 300 ohm, 3.0K ohm, 30K ohm, 300K ohm, 3.0M ohm 3.3 ohm, 33 ohm, 330 ohm, 3.3k ohm, 33k ohm, 330k ohm, 3.3M ohm 3.6 ohm, 36 ohm, 360 ohm, 3.6k ohm, 36k ohm, 360k ohm, 3.6M ohm 3.9 ohm, 39 ohm, 390 ohm, 3.9k ohm, 39k ohm, 390k ohm, 3.9M ohm 4.3 ohm, 43 ohm, 430 ohm, 4.3k ohm, 43K ohm, 430K ohm, 4.3M ohm 4.7 ohm, 47 ohm, 470 ohm, 4.7k ohm, 47k ohm, 470k ohm, 4.7M ohm 5.1 ohm, 51 ohm, 510 ohm, 5.1k ohm, 51k ohm, 510k ohm, 5.1M ohm 5.6 ohm, 56 ohm, 560 ohm, 5.6k ohm, 56k ohm, 560k ohm, 5.6M ohm 6.2 ohm, 62 ohm, 620 ohm, 6.2k ohm, 62K ohm, 620K ohm, 6.2M ohm 6.8 ohm, 68 ohm, 680 ohm, 6.8k ohm, 68k ohm, 680k ohm, 6.8M ohm 7.5 ohm, 75 ohm, 750 ohm, 7.5k ohm, 75k ohm, 750k ohm, 7.5M ohm 8.2 ohm, 82 ohm, 820 ohm, 8.2k ohm, 82k ohm, 820k ohm, 8.2M ohm 9.1 ohm, 91 ohm, 910 ohm, 9.1k ohm, 91k ohm, 910k ohm, 9.1M ohm #generics #CommonPartsLibrary
    jharwinbarrozo
    1.5M
  • Generic Capacitor
    Generic Capacitor
    A generic fixed capacitor ideal for rapid circuit topology development. You can choose between polarized and non-polarized types, its symbol and the footprint will automatically adapt based on your selection. Supported options include standard SMD sizes for ceramic capacitors (e.g., 0402, 0603, 0805), SMD sizes for aluminum electrolytic capacitors, and through-hole footprints for polarized capacitors. Save precious design time by seamlessly add more information to this part (value, footprint, etc.) as it becomes available. Standard capacitor values: 1.0pF, 10pF, 100pF, 1000pF, 0.01uF, 0.1uF, 1.0uF, 10uF, 100uF, 1000uF, 10000uF 1.1pF, 11pF, 110pF, 1100pF 1.2pF, 12pF, 120pF, 1200pF 1.3pF, 13pF, 130pF, 1300pF 1.5pF, 15pF, 150pF, 1500pF, 0.015uF, 0.15uF, 1.5uF, 15uF, 150uF, 1500uF 1.6pF, 16pF, 160pF, 1600pF 1.8pF, 18pF, 180pF, 1800pF 2.0pF, 20pF, 200pF, 2000pF 2.2pF, 22pF, 220pF, 2200pF, 0.022uF, 0.22uF, 2.2uF, 22uF, 220uF, 2200uF 2.4pF, 24pF, 240pF, 2400pF 2.7pF, 27pF, 270pF, 2700pF 3.0pF, 30pF, 300pF, 3000pF 3.3pF, 33pF, 330pF, 3300pF, 0.033uF, 0.33uF, 3.3uF, 33uF, 330uF, 3300uF 3.6pF, 36pF, 360pF, 3600pF 3.9pF, 39pF, 390pF, 3900pF 4.3pF, 43pF, 430pF, 4300pF 4.7pF, 47pF, 470pF, 4700pF, 0.047uF, 0.47uF, 4.7uF, 47uF, 470uF, 4700uF 5.1pF, 51pF, 510pF, 5100pF 5.6pF, 56pF, 560pF, 5600pF 6.2pF, 62pF, 620pF, 6200pF 6.8pF, 68pF, 680pF, 6800pF, 0.068uF, 0.68uF, 6.8uF, 68uF, 680uF, 6800uF 7.5pF, 75pF, 750pF, 7500pF 8.2pF, 82pF, 820pF, 8200pF 9.1pF, 91pF, 910pF, 9100pF #generics #CommonPartsLibrary
    jharwinbarrozo
    1.5M
  • Generic Inductor
    Generic Inductor
    A generic fixed inductor suitable for rapid circuit topology development. The footprint automatically adapts based on the selected package, supporting standard SMD sizes (e.g., 0402, 0603, 0805) as well as well-known inductor packages such as SDR1806, PA4320, SRN6028, and SRR1260. Standard inductor values: 1.0 nH, 10 nH, 100 nH, 1.0 µH, 10 µH, 100 µH, 1.0 mH 1.2 nH, 12 nH, 120 nH, 1.2 µH, 12 µH, 120 µH, 1.2 mH 1.5 nH, 15 nH, 150 nH, 1.5 µH, 15 µH, 150 µH, 1.5 mH 1.8 nH, 18 nH, 180 nH, 1.8 µH, 18 µH, 180 µH, 1.8 mH 2.2 nH, 22 nH, 220 nH, 2.2 µH, 22 µH, 220 µH, 2.2 mH 2.7 nH, 27 nH, 270 nH, 2.7 µH, 27 µH, 270 µH, 2.7 mH 3.3 nH, 33 nH, 330 nH, 3.3 µH, 33 µH, 330 µH, 3.3 mH 3.9 nH, 39 nH, 390 nH, 3.9 µH, 39 µH, 390 µH, 3.9 mH 4.7 nH, 47 nH, 470 nH, 4.7 µH, 47 µH, 470 µH, 4.7 mH 5.6 nH, 56 nH, 560 nH, 5.6 µH, 56 µH, 560 µH, 5.6 mH 6.8 nH, 68 nH, 680 nH, 6.8 µH, 68 µH, 680 µH, 6.8 mH 8.2 nH, 82 nH, 820 nH, 8.2 µH, 82 µH, 820 µH, 8.2 mH #generics #CommonPartsLibrary
    jharwinbarrozo
    15.8k
  • Terminal
    Terminal
    An electrical connector acting as reusable interface to a conductor and creating a point where external circuits can be connected.
    natarius
  • RMCF0805JT47K0
    RMCF0805JT47K0
    General Purpose Thick Film Standard Power and High-Power Chip Resistor 47 kOhms ±5% 0.125W, 1/8W Chip Resistor 0805 (2012 Metric) Automotive AEC-Q200 Thick Film Features: - RMCF – standard power ratings - RMCP – high power ratings - Nickel barrier terminations standard - Power derating from 100% at 70ºC to zero at +155ºC - RoHS compliant, REACH compliant, and halogen free - AEC-Q200 compliant
    jharwinbarrozo
    1.2M
  • 875105359001
    875105359001
    10 µF 16 V Aluminum - Polymer Capacitors Radial, Can - SMD 30mOhm 2000 Hrs @ 105°C #commonpartslibrary #capacitor #aluminumpolymer #radialcan
    jharwinbarrozo
    1.2M
  • CTL1206FYW1T
    CTL1206FYW1T
    Yellow 595nm LED Indication - Discrete 1.7V 1206 (3216 Metric)
    jharwinbarrozo
    1.1M

Empty Tan Transporter

Empty Tan Transporter thumbnail
Welcome to your new project. Imagine what you can build here.

Properties

Properties describe core aspects of the project.

Pricing & Availability

Distributor

Qty 1

Controls

Welcome 👋

Flux helps you build PCBs faster with an AI teammate!

Create your account to collaborate, stay updated, fork your own version, and get instant answers from our AI agent.

      Introducing AI Placement!
      AI Placement Demo

      AI-Powered Component Placement

      Let AI place your components intelligently. AI Placement analyzes your schematic and positions components for optimal routing, signal integrity, and board density.

      From Schematic to Layout in Seconds

      Skip the tedious manual placement. AI Placement generates a starting layout you can refine, saving hours of repetitive work on every new design.

      Works With Auto-Layout

      Pair AI Placement with Auto-Layout for a complete AI-driven PCB design flow — from component placement through trace routing, all with one click.

      Try it