Two-Branch Measurement Method
0:48
Table
| Component | Role | Comments and Suggestions |
|---|---|---|
| High Voltage Source (HV_1000V) | Supplies 1000 VDC | Verify that the high‐voltage source is isolated and that all high‐voltage connections are properly rated. |
| Reference Resistor (R1) | Known resistor in the voltage divider | Ensure its value is chosen for a good measurement range (e.g., 1 MΩ). Confirm that its high‐voltage rating meets 1000 VDC. |
| Insulation Resistor (Rx) | Unknown resistor (insulation under test) | Its value should be very high (typically many MΩ), not something like 500 Ω. Adjust Rx to the expected range. |
| Other Resistors (R0, R2) | Currently present in your schematic | They appear to be interfering with the intended two‐branch divider. For the insulation meter, use only R1 (reference) and Rx. |
| Op-Amp (Voltage Follower) | Buffers the measurement node | Confirm that the op-amp’s input and supply are properly isolated from the high-voltage branch. Decoupling is critical. |
| Decoupling Capacitor (C1) | Stabilizes the op-amp supply | Verify its placement between the op-amp supply and ground. |