PCB Net Routing Assistance

Diagnostic confirmed: the L2/L3 zones have copper geometry but are missing net assignments (effectiveNetId is null), so DRC treats them as decorative copper, not net-bound planes.
Fix in two steps:
STEP 1 — Create missing zones with explicit net assignment
The L2 GND zone and L3 3V0 dominant zone do not exist as proper queryable nodes. Create them now:
a) L2 GND PLANE
  • Layer: Mid-Layer 1 (L2)
  • Net: GND (assign explicitly — set effectiveNetId / net property)
  • Shape: circle, diameter 57.4mm, centred at (0, 0) — slightly smaller than the 58mm board outline to maintain 0.3mm edge clearance
  • Fill type: solid copper pour
  • Connection style: thermal relief to net-matching pads
  • Thermal relief: 4 spokes, 0.4mm spoke width, 0.3mm clearance
  • Stitching density: 2mm
b) L3 3V0 DOMINANT POUR
  • Layer: Mid-Layer 2 (L3)
  • Net: 3V0 (assign explicitly)
  • Shape: circle, diameter 57.4mm, centred at (0, 0), MINUS the two existing island regions (VSYS and 1V8_SGP41) — i.e., the 3V0 pour fills L3 everywhere EXCEPT inside the islands
  • Fill type: solid copper pour
  • Connection: thermal relief, same parameters as L2
STEP 2 — Assign net to existing islands
The L3 VSYS and L3 1V8_SGP41 island zones exist but have no net assignment. Set them now:
c) L3 VSYS ISLAND
  • Existing zone at (10, 18), 10×12mm
  • Net: VSYS (assign explicitly — currently has no effectiveNetId)
d) L3 1V8_SGP41 ISLAND
  • Existing zone at (-10, 22), 8×8mm
  • Net: 1V8_SGP41 (assign explicitly)
After Step 1 and Step 2:
  • Force a pour rebuild / fill regeneration on all 4 zones
  • Verify each zone now reports a valid effectiveNetId matching its intended net
  • Re-run DRC and report:
    • New total airwire count
    • Specifically the GND, 3V0, VSYS, 1V8_SGP41 airwire counts
    • Render each layer (L1, L2, L3, L4) separately so I can verify the copper fills look correct
Expected result: airwire count should drop dramatically (from 170 to under 30), because most of the GND/3V0/VSYS airwires resolve through the now-net-bound planes.
If after this the count is still > 50, do NOT iterate further. Report back and stop. I'll handle the next decision from outside Flux.

0:12

Thought for a moment

I’ll attempt the four-zone net binding exactly as specified, then verify DRC and layer rendering. First I’m checking whether the layout editor exposes net assignment for copper pours; if it does, I’ll apply the plane fixes and validate immediately.

0:33

Thought for 4 sec

1/3 Check whether copper-zone net assignment is editable in the current layout controls

Thought for 6 sec

Thought for 4 sec

3/3 tasks completed.

Thought for a moment

Blocked: I can’t complete this safely because the current layout controls do not expose any editable net/effectiveNetId/net-name property for zones. I verified that connectedLayers, shape, stitching, and thermal-style rules exist, but net, Net Name, and effectiveNetId are not valid editable zone rules.
I did not create more decorative copper, because that would repeat the same failure mode. The next decision needs to happen outside this interface: bind the copper pours to nets in the PCB editor/API, then rerun DRC and layer renders.
Find zone net UI
List airwires by net
Inspect zone properties
Export layout data


  • Generic Inductor
    A generic fixed inductor suitable for rapid circuit topology development. The footprint automatically adapts based on the selected package, supporting standard SMD sizes (e.g., 0402, 0603, 0805) as well as well-known inductor packages such as SDR1806, PA4320, SRN6028, and SRR1260. Standard inductor values: 1.0 nH, 10 nH, 100 nH, 1.0 µH, 10 µH, 100 µH, 1.0 mH 1.2 nH, 12 nH, 120 nH, 1.2 µH, 12 µH, 120 µH, 1.2 mH 1.5 nH, 15 nH, 150 nH, 1.5 µH, 15 µH, 150 µH, 1.5 mH 1.8 nH, 18 nH, 180 nH, 1.8 µH, 18 µH, 180 µH, 1.8 mH 2.2 nH, 22 nH, 220 nH, 2.2 µH, 22 µH, 220 µH, 2.2 mH 2.7 nH, 27 nH, 270 nH, 2.7 µH, 27 µH, 270 µH, 2.7 mH 3.3 nH, 33 nH, 330 nH, 3.3 µH, 33 µH, 330 µH, 3.3 mH 3.9 nH, 39 nH, 390 nH, 3.9 µH, 39 µH, 390 µH, 3.9 mH 4.7 nH, 47 nH, 470 nH, 4.7 µH, 47 µH, 470 µH, 4.7 mH 5.6 nH, 56 nH, 560 nH, 5.6 µH, 56 µH, 560 µH, 5.6 mH 6.8 nH, 68 nH, 680 nH, 6.8 µH, 68 µH, 680 µH, 6.8 mH 8.2 nH, 82 nH, 820 nH, 8.2 µH, 82 µH, 820 µH, 8.2 mH #generics #CommonPartsLibrary
  • Generic Capacitor
    A generic fixed capacitor ideal for rapid circuit topology development. You can choose between polarized and non-polarized types, its symbol and the footprint will automatically adapt based on your selection. Supported options include standard SMD sizes for ceramic capacitors (e.g., 0402, 0603, 0805), SMD sizes for aluminum electrolytic capacitors, and through-hole footprints for polarized capacitors. Save precious design time by seamlessly add more information to this part (value, footprint, etc.) as it becomes available. Standard capacitor values: 1.0pF, 10pF, 100pF, 1000pF, 0.01uF, 0.1uF, 1.0uF, 10uF, 100uF, 1000uF, 10000uF 1.1pF, 11pF, 110pF, 1100pF 1.2pF, 12pF, 120pF, 1200pF 1.3pF, 13pF, 130pF, 1300pF 1.5pF, 15pF, 150pF, 1500pF, 0.015uF, 0.15uF, 1.5uF, 15uF, 150uF, 1500uF 1.6pF, 16pF, 160pF, 1600pF 1.8pF, 18pF, 180pF, 1800pF 2.0pF, 20pF, 200pF, 2000pF 2.2pF, 22pF, 220pF, 2200pF, 0.022uF, 0.22uF, 2.2uF, 22uF, 220uF, 2200uF 2.4pF, 24pF, 240pF, 2400pF 2.7pF, 27pF, 270pF, 2700pF 3.0pF, 30pF, 300pF, 3000pF 3.3pF, 33pF, 330pF, 3300pF, 0.033uF, 0.33uF, 3.3uF, 33uF, 330uF, 3300uF 3.6pF, 36pF, 360pF, 3600pF 3.9pF, 39pF, 390pF, 3900pF 4.3pF, 43pF, 430pF, 4300pF 4.7pF, 47pF, 470pF, 4700pF, 0.047uF, 0.47uF, 4.7uF, 47uF, 470uF, 4700uF 5.1pF, 51pF, 510pF, 5100pF 5.6pF, 56pF, 560pF, 5600pF 6.2pF, 62pF, 620pF, 6200pF 6.8pF, 68pF, 680pF, 6800pF, 0.068uF, 0.68uF, 6.8uF, 68uF, 680uF, 6800uF 7.5pF, 75pF, 750pF, 7500pF 8.2pF, 82pF, 820pF, 8200pF 9.1pF, 91pF, 910pF, 9100pF #generics #CommonPartsLibrary
  • Generic Resistor
    A generic fixed resistor ideal for rapid circuit topology development. Its footprint automatically adapts based on the selected package case code—supporting 0402, 0603, 0805, 1203, and many other standard SMD packages, as well as axial horizontal and vertical configurations. Save precious design time by seamlessly add more information to this part (value, footprint, etc.) as it becomes available. Standard resistor values: 1.0 ohm, 10 ohm, 100 ohm, 1.0k ohm, 10k ohm, 100k ohm, 1.0M ohm 1.1 ohm, 11 ohm, 110 ohm, 1.1k ohm, 11k ohm, 110k ohm, 1.1M ohm 1.2 ohm, 12 ohm, 120 ohm, 1.2k ohm, 12k ohm, 120k ohm, 1.2M ohm 1.3 ohm, 13 ohm, 130 ohm, 1.3k ohm, 13k ohm, 130k ohm, 1.3M ohm 1.5 ohm, 15 ohm, 150 ohm, 1.5k ohm, 15k ohm, 150k ohm, 1.5M ohm 1.6 ohm, 16 ohm, 160 ohm, 1.6k ohm, 16k ohm, 160k ohm, 1.6M ohm 1.8 ohm, 18 ohm, 180 ohm, 1.8K ohm, 18k ohm, 180k ohm, 1.8M ohm 2.0 ohm, 20 ohm, 200 ohm, 2.0k ohm, 20k ohm, 200k ohm, 2.0M ohm 2.2 ohm, 22 ohm, 220 ohm, 2.2k ohm, 22k ohm, 220k ohm, 2.2M ohm 2.4 ohm, 24 ohm, 240 ohm, 2.4k ohm, 24k ohm, 240k ohm, 2.4M ohm 2.7 ohm, 27 ohm, 270 ohm, 2.7k ohm, 27k ohm, 270k ohm, 2.7M ohm 3.0 ohm, 30 ohm, 300 ohm, 3.0K ohm, 30K ohm, 300K ohm, 3.0M ohm 3.3 ohm, 33 ohm, 330 ohm, 3.3k ohm, 33k ohm, 330k ohm, 3.3M ohm 3.6 ohm, 36 ohm, 360 ohm, 3.6k ohm, 36k ohm, 360k ohm, 3.6M ohm 3.9 ohm, 39 ohm, 390 ohm, 3.9k ohm, 39k ohm, 390k ohm, 3.9M ohm 4.3 ohm, 43 ohm, 430 ohm, 4.3k ohm, 43K ohm, 430K ohm, 4.3M ohm 4.7 ohm, 47 ohm, 470 ohm, 4.7k ohm, 47k ohm, 470k ohm, 4.7M ohm 5.1 ohm, 51 ohm, 510 ohm, 5.1k ohm, 51k ohm, 510k ohm, 5.1M ohm 5.6 ohm, 56 ohm, 560 ohm, 5.6k ohm, 56k ohm, 560k ohm, 5.6M ohm 6.2 ohm, 62 ohm, 620 ohm, 6.2k ohm, 62K ohm, 620K ohm, 6.2M ohm 6.8 ohm, 68 ohm, 680 ohm, 6.8k ohm, 68k ohm, 680k ohm, 6.8M ohm 7.5 ohm, 75 ohm, 750 ohm, 7.5k ohm, 75k ohm, 750k ohm, 7.5M ohm 8.2 ohm, 82 ohm, 820 ohm, 8.2k ohm, 82k ohm, 820k ohm, 8.2M ohm 9.1 ohm, 91 ohm, 910 ohm, 9.1k ohm, 91k ohm, 910k ohm, 9.1M ohm #generics #CommonPartsLibrary
  • Ground
    A common return path for electric current. Commonly known as ground.
  • Terminal
    Terminal
    An electrical connector acting as reusable interface to a conductor and creating a point where external circuits can be connected.
  • Net Portal
    Wirelessly connects nets on schematic. Used to organize schematics and separate functional blocks. To wirelessly connect net portals, give them same designator. #portal
  • RMCF0805JT47K0
    General Purpose Thick Film Standard Power and High-Power Chip Resistor 47 kOhms ±5% 0.125W, 1/8W Chip Resistor 0805 (2012 Metric) Automotive AEC-Q200 Thick Film Features: - RMCF – standard power ratings - RMCP – high power ratings - Nickel barrier terminations standard - Power derating from 100% at 70ºC to zero at +155ºC - RoHS compliant, REACH compliant, and halogen free - AEC-Q200 compliant
  • 875105359001
    10 µF 16 V Aluminum - Polymer Capacitors Radial, Can - SMD 30mOhm 2000 Hrs @ 105°C #commonpartslibrary #capacitor #aluminumpolymer #radialcan
  • CTL1206FYW1T
    Yellow 595nm LED Indication - Discrete 1.7V 1206 (3216 Metric)
  • 1070TR
    Battery Holder (Open) Coin, 20.0mm 1 Cell SMD (SMT) Tab bate or batt #forLedBlink

nRF52840 Wearable Power Tree

nRF52840 Wearable Power Tree thumbnail
Battery-powered nRF52840 wearable power-tree schematic with USB-C charging, nPM1100 PMIC, 3V0, 1V8_SGP41, and 5V_SPS30 rails.

Properties

Haelo Clip v2 round-puck PCB: 58 mm circular outline centered at origin; Standard 4 Layer with L2 continuous GND plane, L3 power planes for 3V0/1V8_SGP41/VSYS; requested fabrication notes: 1.0 mm finished thickness, ENIG, matte black solder mask preferred with white silkscreen; matte white mask with black silkscreen acceptable if cheaper at JLCPCB.

Pricing & Availability

Distributor

Qty 1

Arrow

$10.02–$11.43

Digi-Key

$16.02–$20.31

HQonline

$8.71–$8.81

LCSC

$19.40–$20.49

Mouser

$17.72

TME

$8.03

Verical

$12.13–$17.73

Controls

New control