RP2040-Zero Footprint Discussion


Final manufacturing checklist passed for REV A: no open DRC/ERC issues in the checked categories, connector/pinout/power mapping verified, and I added the 5V NC / DO NOT USE silkscreen warning. The only caveat is BOM-only: the 22 bare copper test pads have no MPN, which is expected unless you want assembled test-point hardware.
Project files:
Exports:
Suggested next steps:
  1. Open the Gerber ZIP in JLCPCB/PCBWay viewer and visually confirm board outline, drills, silk, and connector pin-1 marks.
  2. Verify CPL rotations for the two FFC connectors before assembly order.
  3. Continuity-check one FFC cable/wing prototype against the connector-orientation note before powering.
Review exports and BOM
Check Gerber visuals
Verify CPL rotations
Clean BOM caveats
Create bring-up checklist

TP_B
TP_LY
TP_R2
TP_RX
TP_GND
TP_A
H1
H4
H2
TP_START
TP_X
TP_L3
TP_RY
TP_DPAD_LEFT
TP_DPAD_UP
TP_SELECT
TP_R3
TP_DPAD_RIGHT
TP_L2
TP_LX
TP_3V3
H3
TP_Y
TP_R1
TP_L1
TP_DPAD_DOWN
JRIGHT
U1
JLEFT
Connector Orientation Note
Scope
This note defines the FFC/FPC connector orientation that future left and right controller-wing boards must match for the RP2040-Zero Controller Carrier REV A.
Carrier Connectors
  • JLEFT: Molex 0528081471 / 528081471, 14-position, 1.00 mm pitch, vertical FFC/FPC connector on the carrier left edge.
  • JRIGHT: Molex 0528081471 / 528081471, 14-position, 1.00 mm pitch, vertical FFC/FPC connector on the carrier right edge.
  • The cable inserts vertically/upward into the carrier connector first, then bends toward the left or right wing. Maintain vertical clearance above both connectors.
Required Wing-Board Matching Rule
The future left and right wing boards must be pinned so the mating FFC cable presents the same numbered conductor mapping to the carrier connector pins listed below. Do not assume the wing board can reuse the same physical footprint orientation without checking cable contact side, fold direction, and pin-1 side.
JLEFT Carrier Pinout
1 GND; 2 3V3; 3 DPAD_LEFT; 4 DPAD_DOWN; 5 DPAD_UP; 6 DPAD_RIGHT; 7 SELECT; 8 L1; 9 L2; 10 LX; 11 LY; 12 L3; 13 GND; 14 SPARE_LEFT / NC.
JRIGHT Carrier Pinout
1 GND; 2 3V3; 3 A; 4 B; 5 X; 6 Y; 7 START; 8 R1; 9 R2; 10 RX; 11 RY; 12 R3; 13 GND; 14 SPARE_RIGHT / NC.
Bring-Up Warning
Before plugging in wings, continuity-check the FFC cable end-to-end and verify carrier pin 2 routes to the wing 3V3 rail, carrier pins 1/13 route to wing GND, and no signal conductor is swapped by cable flip/contact-side assumptions.
  • Scope

  • Carrier Connectors

  • Required Wing-Board Matching Rule

  • JLEFT Carrier Pinout

  • JRIGHT Carrier Pinout

  • Bring-Up Warning