Circuit Analysis in LaTeX

1:03

Below is an example LaTeX template that you can modify with your test data, graphs, and technical analysis write‑up. You can compile this (with pdflatex or similar) to produce a document with sample graphs generated using pgfplots.

Latex


\documentclass[a4paper,12pt]{article}
\usepackage{pgfplots}         % For plotting charts
\usepackage{amsmath, amssymb}  % For math equations
\usepackage{graphicx}         % For images
\usepackage{booktabs}         % For tables
\usepackage{caption}
\pgfplotsset{compat=newest}

\title{Technical Analysis of the Ultrasonic Distance Meter Circuit}
\author{Your Name}
\date{\today}

\begin{document}
\maketitle

\section{Introduction}
This document presents a technical analysis of the ultrasonic distance meter circuit which is based on an ATTiny2313 microcontroller, the HC-SR04 ultrasonic sensor, and a boost converter (TPS613222A). The following sections include the test data, graphs, and a detailed write‑up of the circuit’s performance.

\section{Test Data}
The test data was collected under various conditions. Table~\ref{tab:data} summarizes key metrics such as measured distance, sensor response time, and voltage levels.

\begin{table}[ht!]
\centering
\caption{Sample Test Data for the Ultrasonic Sensor}
\label{tab:data}
\begin{tabular}{@{}cccc@{}}
\toprule
Test No. & Measured Distance (cm) & Time Delay (µs) & VCC (V) \\ \midrule
1        & 50                     & 290            & 5.0     \\
2        & 100                    & 580            & 5.1     \\
3        & 150                    & 870            & 5.0     \\
4        & 200                    & 1160           & 5.1     \\
5        & 250                    & 1450           & 5.0     \\ \bottomrule
\end{tabular}
\end{table}

\section{Graphical Analysis}
Two key graphs are presented below: one shows the relation between the time delay and the measured distance, and the other illustrates the voltage variation over time.

\subsection{Distance vs. Time Delay}
\begin{center}
\begin{tikzpicture}
\begin{axis}[
    title={Distance vs. Time Delay},
    xlabel={Time Delay (\( \mu s \))},
    ylabel={Distance (cm)},
    grid=major,
    width=0.8\textwidth,
    height=0.5\textwidth,
    legend pos=south east
]
\addplot[
    color=blue,
    mark=square,
    ]
    coordinates {
    (290,50) (580,100) (870,150) (1160,200) (1450,250)
    };
\addlegendentry{Test Data}
\end{axis}
\end{tikzpicture}
\end{center}

\subsection{Supply Voltage Over Time}
\begin{center}
\begin{tikzpicture}
\begin{axis}[
    title={VCC over Time},
    xlabel={Time (s)},
    ylabel={VCC (V)},
    grid=major,
    width=0.8\textwidth,
    height=0.5\textwidth,
    legend pos=south east
]
\addplot[
    color=red,
    mark=o,
    smooth,
    ]
    coordinates {
    (0,5.0) (1,5.1) (2,5.0) (3,5.1) (4,5.0)
    };
\addlegendentry{VCC Variation}
\end{axis}
\end{tikzpicture}
\end{center}

\section{Technical Analysis}
Based on the collected data and the circuit design, we perform the following analysis:

\subsection{Sensor Response}
The measured time delay \( T \) (in microseconds) is related to the distance \( d \) (in cm) by the equation:
$$
\Large d = \frac{T \times V_{sound}}{2 \times 10^4}
$$
where \( V_{sound} \) (in cm/s) is approximately 34300 cm/s. For example, substituting \(T = 580\,\mu s\) gives:
$$
\Large d = \frac{580 \times 34300}{2 \times 10^4} \approx 99.37 \text{ cm}
$$

\subsection{Power Supply Stability}
The boost converter (TPS613222A) maintains a stable output, as shown by the slight variation in VCC from 5.0V to 5.1V. This minor ripple is within acceptable limits for the ATTiny2313.

\subsection{Overall System Behavior}
The linear relationship between the time delay and the measured distance confirms the expected behavior of the ultrasonic sensor. The circuit design provides reliable operation even with minimal voltage variation.

\section{Conclusion}
The technical analysis demonstrates that the ultrasonic distance meter circuit performs as expected. The sensor output correlates well with the theoretical predictions, and the boost converter ensures stable operation for the microcontroller. Further tests can be added to explore dynamic range and response times under varying environmental conditions.

\end{document}
This template includes sections for test data, graphical representations (using pgfplots), and technical analysis with equations in LaTeX. You can update the tables, coordinates, and equations with your specific test measurements and analysis details.
Clarify desired analysis
267 days

To get started, talk to Flux or create a New Document.

Documents

    Documents are markdown text files which describe project goals, capture details, or even simulation outputs.

    Assets

    Ultrasonic Distance Meter Reference Design-removebg-preview (1).png

    Ultrasonic Distance Meter Reference Design-removebg-preview (1).png

    Ultrasonic Distance Meter Reference Design-removebg-preview (1)Thumbnail

    Ultrasonic Distance Meter Reference Design

    Ultrasonic Distance Meter Reference Design thumbnail
    This circuit is an ultrasonic distance meter based on an ATTiny2313 microcontroller. It uses an HC-SR04 ultrasonic sensor to measure distance and displays the results on an OLED display. The power supply is constructed using a Boost converter (TPS613222A) and a 2-cell AA battery. Additionally, it also includes ISP for programming, RESET and START switches, and LED indicators. #project #Template #projectTemplate #ultrasonic #OLED #arduino #attiny2313 #TPS613222A #ISP #referenceDesign #simple-embedded #microchip #template #reference-design

    Pricing & Availability

    Distributor

    Qty 1

    Controls