Part Metadata Audit and Verification

Review all available part information (MPN, package, pin count, description, properties). If no datasheet URL is already set, search the web for the official datasheet and update the part's Datasheet property with the URL. Then cross-check the schematic symbol, footprint, and pin descriptions against the datasheet. Summarize key specs and flag any mismatches.

0:17

Thought for 5 sec

Thought for 8 sec

Thought for a moment

I’ll audit the relay part metadata, find/update the official datasheet if needed, then compare the symbol pins and PCB footprint against the datasheet and record the detailed findings in a project file.

2:52

Thought for 3 sec

Created 5 tasks.

1/5 Inspect existing part metadata, schematic symbol pins, and PCB footprint/pads

Thought for 3 sec

Read BOM.

Read schematic.

Read layout.

Thought for 4 sec

2/5 Find official datasheet URL if missing and update Datasheet URL property

Thought for 3 sec

Read TQ2SA-L2-3V-Z datasheet for pin configuration pin description.

Read TQ2SA-L2-3V-Z datasheet for general specifications coil rating conta.

Searched "What project-level properties are currently set fo..." — 157 results.

Found 10 results for Panasonic TQ2SA-L2-3V-Z official datasheet PDF.

Found 5 results for site:panasonic.com TQ2SA-L2-3V-Z datasheet.

Thought for 5 sec

Thought for 4 sec

Thought for 4 sec

Thought for 5 sec

Thought for a moment

Read "Find package/style, description, and number of pins/terminals for manufacturer part number TQ2SA-L2-3V-Z." in mech_eng_tq.pdf.

Read mech_eng_tq.pdf.

Thought for 3 sec

Thought for 2 sec

Thought for 16 sec

Thought for a moment

I found the Panasonic datasheet already set on the part, so no Datasheet URL update is needed. I’m extracting the official pinout/specs now and checking them against the symbol and footprint.

17:54

Found 10 results for "TQ2SA-L2-3V-Z" "1 =" "NC".

Found 5 results for "TQ2SA" "9876" "12345".

Thought for 4 sec

Analyzing in depth.

Read TQ2SA12VZ.html.

Read TQ2SS-1.5V-X.html.

Thought for 5 sec

Thought for a moment

Analyzing in depth.

Thought for 1 sec

Analyzing in depth.

Read TQ2SS-1.5V-X.html.

Thought for 5 sec

Analyzing in depth.

Running code.

Code executed.

Thought for 6 sec

Thought for a moment

Analyzing in depth.

Read "For TQ2SA-L2 2 coil latching surface mount top view, which exact pin numbers are SET coil plus/minus and RESET coil plus/minus? Are coils on pins 1 5 6 10 or 3 4 7 8?" in ds_61020_en_tq.pdf.

Read "TQ2SA-L2 2 coil latching: pin 3 pin 4 pin 7 pin 8 coil terminals? polarity + - reset set Panasonic" in ds_61020_en_tq.pdf.

Read ds_61020_en_tq.pdf.

Read ds_61020_en_tq.pdf.

Thought for 3 sec

Thought for a moment

Analyzing in depth.

Read api.pim.na.industrial.panasonic.com.

Thought for 3 sec

Analyzing in depth.

Read "TQ2SA-L2-3V-Z pinout schematic top view 2 coil latching coil polarity contact pins recommended footprint dimensions" in api.pim.na.industrial.panasonic.com.

Read api.pim.na.industrial.panasonic.com.

Thought for 3 sec

Analyzing in depth.

Found 10 results for AllDatasheet TQ2SA-L2-3V-Z 9/11 schematic 2-coil latching top view.

Thought for 2 sec

Analyzing in depth.

Read "TQ2SA surface mount schematic top view 2 coil latching reset condition pin numbers coil polarity + - contact pins NO NC COM orientation stripe" in TQ2SA-5V-Z-Panasonic-datasheet-10508975.pdf.

Read TQ2SA-5V-Z-Panasonic-datasheet-10508975.pdf.

Thought for 9 sec

Analyzing in depth.

Read "From the surface mount schematic top view, identify exact function of each pin 1 through 10 for TQ2SA 2 Form C 2 coil latching. Is pin 1 NC or coil?" in TQ2SA-5V-Z-Panasonic-datasheet-10508975.pdf.

Read "TQ2SA-L2 pin assignment pin 1 pin 2 pin 3 pin 4 pin 5 pin 6 pin 7 pin 8 pin 9 pin 10 NC COM NO coil" in TQ2SA-5V-Z-Panasonic-datasheet-10508975.pdf.

Read TQ2SA-5V-Z-Panasonic-datasheet-10508975.pdf.

Read TQ2SA-5V-Z-Panasonic-datasheet-10508975.pdf.

Thought for 8 sec

Thought for a moment

Analyzing in depth.

Found 1 results for "TQ2SA-L2-3V-Z" KiCad symbol pinout.

Found 1 results for "TQ2SA-L2" "KiCad" "Relay_DPDT".

Found 10 results for "TQ2SA-L2" "Footprint" "pins".

Thought for 2 sec

Analyzing in depth.

Read snapeda.com.

Thought for 4 sec

Thought for a moment

Analyzing in depth.

Thought for 2 sec

Analyzing in depth.

Found 1 results for TQ2SA-L2-3V-Z.

No results for ATQ221SAZ.

Thought for 10 sec

Thought for 10 sec

Thought for 7 sec

Thought for a moment

Analyzing in depth.

Read forum.allaboutcircuits.com.

Found 1 results for "TQ2SA-L2" "pins 5" "pins 6" "coil".

Found 4 results for "TQ2SA-L2" "+" "pin 1" "pin 10".

Thought for 27 sec

Thought for 4 sec

Thought for 2 sec

Thought for 2 sec

Thought for 2 sec

Thought for a moment

Analyzing in depth.

Read "TQ2SA-L2-3V-Z 3V coil table: set voltage reset voltage nominal operating current coil resistance nominal operating power maximum allowable voltage operate time release time pulse duration" in ds_61020_en_tq.pdf.

Read "TQ relay contact ratings 2 Form C standard type nominal switching capacity max switching power max switching voltage max switching current minimum switching capacity contact resistance" in ds_61020_en_tq.pdf.

Read "TQ2SA surface mount SA type external dimensions recommended PC board pattern dimensions length width height row spacing pad pitch pad size 11.5 7.62 9.56 2.54 2.94" in ds_61020_en_tq.pdf.

Read ds_61020_en_tq.pdf.

Read ds_61020_en_tq.pdf.

Read ds_61020_en_tq.pdf.

Thought for 11 sec

Thought for 5 sec

Thought for 4 sec

Thought for 36 sec

Thought for 21 sec

Thought for a moment

4/5 Cross-check symbol, footprint, pin descriptions, and properties against datasheet

Thought for a moment

Thought for 3 sec

Read schematic.

Thought for 4 sec

5/5 Create audit report project file and summarize findings

Thought for 41 sec

Thought for 4 sec

5/5 tasks completed.

Thought for a moment

Audit complete. The Panasonic datasheet URL was already present, so I did not change it; I added missing pin descriptions and set all relay terminals to Passive. No hard symbol/footprint mismatches were found; the only caution is to visually confirm polarized coil polarity against the original PDF artwork before production release due to garbled OCR.
Verify coil polarity
Run ERC/DRC
Check pad numbering
Document caution

Refine this doc
Ask about this doc
Part Audit: Panasonic TQ2SA-L2-3V-Z
Date: 2026-05-21
Scope
Reviewed available part information, official Panasonic sources, schematic symbol terminals, PCB footprint, and pin descriptions for the Flux part project TQ2SA-L2-3V-Z.
Existing Part Metadata

Table


FieldCurrent / Found ValueNotes
ManufacturerPanasonicProject data reports Panasonic. Official product pages identify Panasonic Industry / Automation Controls.
Manufacturer Part NumberTQ2SA-L2-3V-ZOfficial Panasonic product number.
Ordering / part numberATQ221SAZPanasonic ordering part number for TQ2SA-L2-3V-Z.
Part typeRelaySignal / telecom relay.
Designator prefixKSuitable for relay.
Contact arrangement2 Form CDPDT changeover contacts.
Terminal / packageSurface-mount terminal, SA typeTape-and-reel Z suffix.
Pin / pad count10Symbol and footprint both expose 10 terminals/pads.
Datasheet URLhttps://industry.panasonic.com/ac/cdn/e/control/relay/signal/catalog/mech_eng_tq.pdfAlready present; no update required.
3D modelTQ2SA-L2-3V-Z.stpPresent.
Footprint assetTQ2SAL23VZ.kicad_modPresent.
Official Sources Checked
Key Datasheet / Product Specs

Table


ParameterValue
Operating function2 coil latching type
Coil voltage3 V DC
Rated operating power140 mW
Coil current46.7 mA set coil, 46.7 mA reset coil at 20 C
Coil resistance64.3 ohms set coil, 64.3 ohms reset coil at 20 C
Set voltageMax. 75% of rated coil voltage, initial
Reset voltageMax. 75% of rated coil voltage, initial
Max allowable coil voltage150% of rated coil voltage at 20 C
Recommended driveSquare pulse drive; do not energize set and reset coils simultaneously
Contact materialAgNi + Au clad
Contact rating, resistive2 A 30 V DC; 0.5 A 125 V AC
Max switching power60 W DC; 62.5 VA AC
Max switching voltage220 V DC; 125 V AC
Max switching current2 A DC; 2 A AC
Min switching load10 uA 10 mV DC, reference value
Initial contact resistanceMax. 75 mOhm, by voltage drop 6 V DC 1 A
Operate / set timeMax. 4 ms at rated coil voltage, 20 C, without bounce
Release / reset timeMax. 4 ms at rated coil voltage, 20 C, without bounce
Initial dielectric strength1,000 Vrms open contacts; 1,500 Vrms contact-coil; 1,500 Vrms between contact sets
Operating / storage conditions-40 C to +85 C, 5% to 85% RH, avoid icing/condensation; derate to max 1 A above 70 C per catalog note
Mechanical lifeMin. 100 x 10^6 operations
Electrical lifeMin. 100 x 10^3 operations at 2 A 30 V DC resistive; min. 200 x 10^3 at 1 A 30 V DC resistive; min. 100 x 10^3 at 0.5 A 125 V AC resistive
Body dimensions14.0 mm x 9.0 mm nominal footprint family; Panasonic product page height 5.6 mm
WeightApprox. 2 g
Note: A generic datasheet query can surface a standard-contact 200 mW coil table. The exact product page and exact TQ2SA-L2-3V-Z / ATQ221SAZ row identify this part as the 140 mW SA type; use the 140 mW, 46.7 mA, 64.3 ohm values for this MPN.
Symbol Pin Cross-Check
Existing terminal mapping after review:

Table


PinSymbol terminalFunction
1COIL1+Set coil positive terminal
2NC1Normally closed contact, pole 1
3COM1Common contact, pole 1
4NO1Normally open contact, pole 1
5COIL1-Set coil negative terminal
6COIL2-Reset coil negative terminal
7NO2Normally open contact, pole 2
8COM2Common contact, pole 2
9NC2Normally closed contact, pole 2
10COIL2+Reset coil positive terminal
The symbol exposes all 10 relay terminals and the contact groups match the Panasonic 2 Form C topology. The Panasonic datasheet schematic is printed as top/bottom views and the OCR output is partially garbled; the current symbol naming follows the visible pin numbering/contact grouping and common TQ2SA-L2 pin convention. Coil polarity should still be visually checked against the PDF schematic before releasing the library part because polarized latching relay coil polarity is safety-critical.
Footprint Cross-Check
Existing footprint pads:

Table


PadPosition (mm)Size (mm)Type
1-5.08, +4.781.00 x 2.94SMD rectangle
2-2.54, +4.781.00 x 2.94SMD rectangle
30.00, +4.781.00 x 2.94SMD rectangle
4+2.54, +4.781.00 x 2.94SMD rectangle
5+5.08, +4.781.00 x 2.94SMD rectangle
6+5.08, -4.781.00 x 2.94SMD rectangle
7+2.54, -4.781.00 x 2.94SMD rectangle
80.00, -4.781.00 x 2.94SMD rectangle
9-2.54, -4.781.00 x 2.94SMD rectangle
10-5.08, -4.781.00 x 2.94SMD rectangle
The footprint matches the Panasonic SA recommended PC board pattern dimensions captured from the datasheet: 2.54 mm pad pitch along each row, 9.56 mm row spacing, and 1.00 mm x 2.94 mm recommended SMD pads. Body/fab outline is 14 mm x 9 mm, matching the datasheet family dimensions. Courtyard is larger than the relay body and acceptable.
Mismatches / Issues Found

Table


SeverityItemStatus
LowTerminal pin descriptions were missing / generic before audit.Fixed: added Pin Description for all 10 terminals.
LowTerminal Pin Type values were Unspecified.Fixed: set all terminal Pin Type values to Passive.
LowPackage field was not found as a project-level property in semantic project search.Not changed; footprint asset and product description clearly identify SA surface-mount terminal package.
LowPin count was not found as a project-level property in semantic project search.Not changed; project context reports Pads: 10 and symbol/footprint both have 10 pins/pads.
CautionOCR extraction of Panasonic schematic polarity is imperfect.No symbol/footprint mismatch found, but manual visual confirmation of coil polarity in the PDF is recommended before production release.
Updates Made
  • Confirmed the official Panasonic datasheet URL is already present; no Datasheet URL update required.
  • Added pin descriptions for all 10 schematic terminals.
  • Changed all terminal Pin Type values from Unspecified to Passive.
Overall Result
No hard symbol or footprint mismatches were found. The footprint dimensions match the SA type recommended PCB pattern, the symbol exposes the correct 10 relay terminals, and the project already references the official Panasonic datasheet. The only issues found were incomplete pin metadata, which have been corrected, plus a caution to visually verify polarized coil polarity against the original PDF artwork before release.

    Scope

    Existing Part Metadata

    Official Sources Checked

    Key Datasheet / Product Specs

    Symbol Pin Cross-Check

    Footprint Cross-Check

    Mismatches / Issues Found

    Updates Made

    Overall Result

Documents

    Part Audit: Panasonic TQ2SA-L2-3V-Z

Assets

TQ2SA-L2-3V-Z-thumb.png

TQ2SA-L2-3V-Z-thumb.png

TQ2SA-L2-3V-Z-thumbThumbnail
kicad_mod

TQ2SA-L2-3V-Z

TQ2SAL23VZ.kicad_modFootprint
stp

TQ2SA-L2-3V-Z

TQ2SA-L2-3V-Z.stp3D Model
TQ2SA-L2-3V-Z

TQ2SA-L2-3V-Z

TQ2SA-L2-3V-Z Symbol.svgDefault

TQ2SA-L2-3V-Z

TQ2SA-L2-3V-Z thumbnail
Flat, 5 mm 2 Form C, 2 A, relays Telecom Relay DPDT (2 Form C) Surface Mount
The TQ2SA-L2-3V-Z is a compact surface-mount DPDT (2 Form C) telecom/signal relay from Panasonic Industry designed for low-power switching applications. It features a dual-coil latching mechanism, allowing the relay to maintain its state without continuous coil power, making it suitable for battery-powered and energy-efficient systems. This relay is commonly used in telecommunications equipment, industrial controls, measurement devices, and embedded electronic systems.
Key Features DPDT (2 Form C) contact configuration 3V DC dual-coil latching relay Low power consumption: approximately 140 mW Compact SMD package: only 5.6 mm height Surface-mount gull-wing terminals Sealed construction for automatic washing compatibility High switching capability: up to 2 A Wide switching voltage range: up to 125 VAC / 220 VDC Fast operate/release time: approx. 4 ms High dielectric strength and surge resistance Wide operating temperature: −40°C to +85°C Gold-clad AgNi contacts for reliable low-level signal switching Tape-and-reel packaging (“Z” suffix) for automated assembly #CommonPartsLibrary #relay

Properties

TQ2SA-L2-3V-Z

Panasonic

Relay

K

parametric-v1

Pricing & Availability

See prices from popular manufacturers for your project.

Controls