B3FS-1002P Usage Guide


I’ll research Omron’s B3FS-1002P datasheet and verified alternatives, then create a cited application and usage guide in the project files.
The manufacturer specifies this switch as unsealed and non-washable, contrary to the current project description. I’ll highlight that correction and distinguish the two verified functional alternatives from unverified drop-in replacements.
Created a project doc

B3FS-1002P Application and Usage Guide

View Document

B3FS-1002P Application and Usage Guide
The Omron B3FS-1002P is a top-actuated, surface-mount tactile pushbutton with an SPST normally-open contact and a 3.1 mm actuator height. Its common integration is an active-low microcontroller user-input button, using a pull-up resistor and debouncing rather than directly switching a power load.
Important correction: B3FS is a standard, unsealed, non-washable switch—not a sealed or waterproof switch. Omron lists IEC IP00 and explicitly prohibits washing; the existing project description's sealed-construction claim should not be used for design qualification. [^flux:cite:src_page_5_tr_td_r...
Created the cited B3FS-1002P Application and Usage Guide in the project files, covering all seven requested sections, practical GPIO wiring, debouncing, alternatives, and sourcing.
The guide flags an important correction: this switch is unsealed and non-washable, contrary to the project description. Exact footprint dimensions and drop-in compatibility remain explicitly unverified; the existing part and description were not changed.

B3FS-1002P Application and Usage Guide
The Omron B3FS-1002P is a top-actuated, surface-mount tactile pushbutton with an SPST normally-open contact and a 3.1 mm actuator height. Its common integration is an active-low microcontroller user-input button, using a pull-up resistor and debouncing rather than directly switching a power load.
Important correction: B3FS is a standard, unsealed, non-washable switch—not a sealed or waterproof switch. Omron lists IEC IP00 and explicitly prohibits washing; the existing project description's sealed-construction claim should not be used for design qualification.
1. Quick Specifications
Omron provides Ratings/Characteristics, not a semiconductor-style Absolute Maximum Ratings table. Treat the upper rated load values as operating limits for the stated resistive-load application; do not reinterpret test voltages as permissible switching voltages.

Table


ParameterVerified specification or practical conditionClassification / qualification
Contact formSPST-NO. Manufacturer contact configuration; no polarity or power-supply pin.
Rated voltage and current1–50 mA, 3–24 VDC, resistive load. Rated operating envelope, not separately published absolute maxima; maximum rated values are 50 mA and 24 VDC.
Minimum applicable load10 µA at 1 VDC, resistive load. Manufacturer reference value, not a guaranteed universal low-current limit. Validate low-level switching in the actual environment.
Typical circuit supply3.3 V or 5 V GPIO supply with a 10 kΩ pull-up; pressed-state current 0.33 mA or 0.50 mA respectively.Proposed application values, calculated using I = V/R; below the rated-load table's 1 mA lower bound, so qualify against the reference minimum-load guidance.
Ambient operating temperature−25°C to +70°C, 60% RH maximum, no icing or condensation. Specified operating conditions. A separate storage-temperature range was not verified.
Initial contact resistance100 mΩ maximum. Initial characteristic, not a lifetime guarantee.
Contact bounce5 ms maximum. Allow for debounce on both press and release.
Operating force1.47 ±0.49 N {150 ±50 gf}. B3FS-1002P high-force variant.
Pretravel0.25 +0.2/−0.1 mm. Do not treat pretravel as allowable enclosure overtravel.
Durability300,000 operations minimum. Manufacturer durability specification; qualify under application conditions.
Package and heightFour-terminal SMT flat-plunger switch; height 3.1 mm. Body outline listed by LCSC as 6.3 × 6.0 mm, with gull-wing terminals (distributor product data).Body outline is distributor-listed; it is not a complete footprint definition.
Terminal pitch and land patternExact numeric pitch, pad sizes, and dimensional tolerances remain unverified in this guide.Use the first Flat Type drawing on datasheet page 3 for B3FS-1002P; do not build or approve a footprint from the body outline alone.
Environmental protectionIEC IP00; washing not possible. No verified water- or dust-sealing claim.
2. Pinout & Connections
The four terminals represent two electrical nodes, not four independent contacts: terminals 1 and 2 are permanently connected, and terminals 3 and 4 are permanently connected. Node names below are application labels, not manufacturer-assigned pin names.

Table


Pin NumberPin NameDescriptionBest Practice
1Contact AInternally common with terminal 2. Connect to the button input node; provide a pull-up to the GPIO's own supply.
2Contact A duplicateInternally common with terminal 1. Route to the same input net as pin 1; never connect the duplicates to conflicting nets.
3Contact BInternally common with terminal 4. Tie to GND for an active-low button circuit.
4Contact B duplicateInternally common with terminal 3. Tie to the same GND net as pin 3.
Orientation: Omron defines numbering using a bottom-view reference with terminals on the right and left and the OMRON logo upright; its terminal-arrangement and PCB-pad graphics are explicitly top views. Do not assign pad numbers by visual proximity or reuse another manufacturer's numbering. Before assembly approval, check an unpowered sample: 1–2 and 3–4 should show continuity without pressing; a measurement between the two groups should change from open to continuity when pressed.
3. Standard Application Circuit
B3FS-1002P microcontroller button wiring
Use an active-low GPIO input:

Text


GPIO supply (3.3 V, or 5 V only for a compatible GPIO)
    |
   RPU = 10 kΩ
    |
    +------ BUTTON_INPUT ------ MCU GPIO input
    |
 SW terminals 1 and 2
    o
    /  normally-open contact
    o
 SW terminals 3 and 4
    |
   GND
  • Required bias: Populate a 10 kΩ external pull-up as a practical starting value, or enable a documented internal pull-up that remains active in the required reset/sleep states. The 10 kΩ value is an engineering recommendation, not an Omron requirement. The input is high when released and low when pressed.
  • Pressed-state current: I = VGPIO/RPU. At 3.3 V, I = 0.33 mA and resistor dissipation P = V²/R = 1.09 mW; at 5 V, I = 0.50 mA and P = 2.50 mW. These values are below the 1 mA lower bound of Omron's rated-load table, but above its 10 µA at 1 VDC reference minimum applicable load; actual low-current contact reliability still needs qualification.
  • If qualification requires staying inside the rated-load range: Use, for example, 2.2 kΩ instead, producing approximately 1.50 mA at 3.3 V or 2.27 mA at 5 V. These are derived application currents, not additional manufacturer ratings; consider the battery-life impact of a held button.
  • Required event filtering: A reasonable firmware starting point is to accept a state only after it remains unchanged for 10 ms, applied independently to both press and release. This proposed interval exceeds the specified 5 ms maximum bounce; verify it with the actual sampling rate and application latency requirement. Do not count every interrupt edge as a separate press.
  • Optional analog filtering: If needed, put 1 kΩ between BUTTON_INPUT and the GPIO, with 100 nF from the GPIO-side node to GND, using a Schmitt-trigger input or buffer. For the 10 kΩ pull-up example, approximate time constants are 0.10 ms when pressing and 1.10 ms when releasing; this filters short glitches but does not replace firmware debounce. These passive values are engineering starting points, not manufacturer recommendations. Check GPIO threshold, leakage, and allowed edge-rate requirements.
  • Supply compatibility: Pull up to the input's permitted logic supply, not to a higher voltage merely because the switch is rated for 24 VDC. Do not connect a 5 V pull-up to a non-5-V-tolerant 3.3 V GPIO. Configure the MCU pin as an input; a push-pull output driven high would be shorted to ground on pressing.
The switch itself needs no supply decoupling capacitor. USB CC resistors, LED series-resistor calculations, differential-pair constraints, and high-current power-path design are not applicable to this standalone tactile switch.
4. PCB Layout & Routing Guidelines
  • Land pattern and numbering: Use the manufacturer B3FS-1002P Flat Type PCB-pad drawing and reconcile it with the symbol's two internally common terminal pairs. The source drawing is labeled for a 1.6 mm PCB; exact pad dimensions and pitch were not reliably verified in this guide, so check the drawing directly before approving any Flux or JLCPCB assembly footprint. A generic “6 × 6 mm tactile” footprint is not sufficient evidence of fit.
  • Routing and filtering: Keep the GPIO/input route short and away from switching nodes, clocks, and exposed high-voltage nets. Ordinary logic-signal trace sizing is appropriate; the switch is not a high-current power switch. Put any optional GPIO filter capacitor close to the receiving input and its ground return. Differential-pair routing is not required.
  • Thermal balance: Avoid connecting one pad to a massive copper pour while leaving the others lightly connected; use consistent connections or appropriate thermal relief after validating the reflow process. As an engineering qualification step, test solderability and heat exposure on the actual multilayer PCB rather than assuming a reference heating profile works unchanged.
  • Mechanical loading: Support the PCB near the button and align the enclosure pusher for straight, centered actuation. Provide clearance at rest and a mechanical travel stop; do not infer allowable overtravel from the pretravel specification. This is integration guidance, not a verified maximum overtravel rating.
  • Assembly cleanliness and heat: Use a non-wash process and keep flux, cleaning fluid, and depanelization debris out of the switch. B3FS is unsealed and cannot be washed. Omron's common precautions specify manual soldering at a 350°C maximum iron-tip temperature for 3 s maximum on a 1.6 mm single-side PCB; no more than two soldering operations, with five minutes between them. The exact reflow time/temperature curve was not verified here—qualify it from the applicable manufacturer precautions, not these manual-soldering limits.
5. Common Pitfalls / Things to Watch Out For
  1. Treating duplicate terminals as opposite switch contacts or leaving the input floating. Pins 1–2 are internally common, as are 3–4; wiring a sensing circuit across one common pair gives an always-connected path. Use one node from each group, bias the input explicitly, and debounce press and release because bounce can last up to 5 ms.
  2. Assuming this is a sealed, washable switch. B3FS is classified as non-washable, standard construction; washing can carry flux and contaminants into the contacts and cause malfunction. Use appropriate enclosure protection if moisture or dust is expected; do not rely on the current project description's sealing claim.
Both parts below were found in the Flux library and verified against manufacturer sources. Neither is a verified drop-in, pin-compatible, or footprint-compatible replacement. Treat them as functional alternatives requiring a footprint, electrical-rating, actuator-height, and enclosure review.

Table


AlternativeVerified characteristicsCompatibility and supply-substitution warning
E-Switch TL3301NF160QG50 mA at 12 VDC; SPST; N actuator 4.3 mm; F160 force 160 gf. Manufacturer product page identifies SPST-NO, Off-(On) momentary operation (E-Switch product page).Functionally similar only. Taller than B3FS-1002P, with a lower voltage rating; 24 V operation is not equivalent. Pad-number compatibility and footprint interchangeability are unverified.
C&K / Littelfuse PTS645SM43SMTR92 LFSMomentary SPST-NO; maximum 50 mA at 12 VDC and minimum 10 µA at 1 VDC. Specific orderable variant: SMT gull-wing, 4.3 mm height, 1.6 ±0.3 N actuation force. Functionally similar only. Taller actuator and different force specification; maximum voltage is 12 VDC. Validate the exact land pattern and terminal mapping rather than reusing the Omron footprint.
No cross-manufacturer drop-in replacement was established by the research. Library presence does not constitute a physical-fit or assembly qualification.
7. Sourcing & Purchasing Guide

Table


AttributeDetails
Primary DistributorsVerified listings: DigiKey, Mouser, Arrow, and LCSC C87038. These are listing confirmations, not a guarantee of current stock or universal franchise status; confirm manufacturer authorization for the purchasing region.
Packaging OptionsManufacturer B3FS-1002P: embossed tape, 3,000-piece packing unit. Distributor cut-tape and custom reeling options depend on the seller; DigiKey's direct page could not be read, so its current cut-tape/Digi-Reel offerings and MOQ were not independently verified.
Standard MOQManufacturer minimum packing unit: 3,000 pieces; manufacturer orders must be multiples of the minimum order unit. LCSC's retrieved product listing specifies minimum 5, multiple 5 (LCSC); reconfirm before ordering. A universal one-piece cut-tape MOQ is not verified.
Sourcing AdviceUse manufacturer-authorized/franchised distributors with traceable supply, not unverified marketplace stock. Match the complete B3FS-1002P order code, actuator height, force, and tape packaging; nearby B3FS variants are not automatically mechanically equivalent. Confirm reel size, feeder orientation, lead time, current lifecycle, and any seller-specific suffix before releasing the purchase order. For JLCPCB assembly, confirm the exact MPN and the current assembly-catalog availability separately; an LCSC listing alone does not prove assembly availability.
Branding and freshness: The manufacturer's Americas product page now displays ARATAS Americas, formerly Omron Components, while the archived technical datasheet is Omron-branded (manufacturer B3FS page). Preserve the MPN and obtain traceable documentation when a distributor uses updated branding. Distributor terms were checked during this research on October 7, 2026; no stock counts or price commitments are included.
Sources
  • Omron B3FS Tactile Switch (SMT) datasheet: primary source for ratings, characteristics, ordering units, and the page 3 Flat Type drawing. Catalog identifier A113-E1-06 is verified; an explicitly labeled PDF revision date was not verified.
  • Omron Tactile Switches Group Catalogue, X037-E1-11B: primary manufacturer source for common safety precautions, unsealed/non-washable classification, and manual soldering limits; relevant precautions on PDF page 5. Publication date was not verified.
  • Manufacturer B3FS product page: current branding and manufacturer document directory; the page lists a B3FS datasheet update of 11/01/2024 and safety-precautions update of 04/01/2025. These are website update dates, not asserted revisions of the archived PDF above.
  • E-Switch TL3301 manufacturer datasheet and TL3301 manufacturer product page: alternative's electrical rating, option coding, height, force, and switch function. A document date appears in search extraction, but was not independently verified and is not used as a revision claim.
  • C&K / Littelfuse PTS645 manufacturer datasheet: alternative's ratings, contact form, and exact orderable surface-mount variant. Document revision/date was not verified.
  • LCSC B3FS-1002P / C87038 product listing: distributor-primary source for listed body outline and minimum-order/multiple information. Distributor data is not used to replace manufacturer qualification drawings.
Unverified items deliberately not invented: numeric footprint pitch/pad dimensions/tolerances; separate storage-temperature limits; maximum permitted overtravel; exact applicable reflow curve; cross-manufacturer drop-in compatibility; and current DigiKey one-piece MOQ. This guide documents integration guidance only—it does not approve or alter the existing symbol, footprint, project description, or assembly process.
  • 1. Quick Specifications

  • 2. Pinout & Connections

  • 3. Standard Application Circuit

  • B3FS-1002P microcontroller button wiring

  • 4. PCB Layout & Routing Guidelines

  • 5. Common Pitfalls / Things to Watch Out For

  • 6. Popular Alternatives & Equivalents

  • 7. Sourcing & Purchasing Guide

  • Sources