a parallel power distribution circuit based on my specifications.
Components needed:
One 24V power input terminal.
One GND terminal.
One Fuse Holder connected directly to the 24V input line.
Eight (8) Red 4mm PCB-mount banana sockets, all connected in parallel to the 24V line AFTER the fuse holder.
Eight (8) Black 4mm PCB-mount banana sockets, all connected in parallel directly to the GND line.
Eight (8) 160 Ohm high-power resistors (R1 through R8). Each resistor should connect between the GND line and a dedicated Green 4mm PCB-mount banana socket.
Eight (8) Green 4mm PCB-mount banana sockets, each connected to its respective 160 Ohm resistor (R1-R8).
Layout requirements:
Group each set of connectors together as a channel (Red + Black + Green + Resistor).
Ensure the main 24V and GND traces are wide enough to handle the total distribution current.
Use robust through-hole (THT) footprints for the 4mm banana sockets to ensure mechanical stability.
One fuse holder in series directly after the 24 V input.
Eight red 4 mm PCB-mount banana sockets connected in parallel to the fused 24 V bus.
Eight black 4 mm PCB-mount banana sockets connected in parallel to the GND bus.
Eight green 4 mm PCB-mount banana sockets. Each green socket connects through its own 160 ohm high-power resistor (R1–R8) to GND. Green sockets are not connected directly to the 24 V bus.
Arrange eight channels, each containing one red socket, one black socket, one green socket, and its resistor.
Use mechanically robust through-hole banana sockets.
Size the main 24 V and GND copper for the total distribution current.
I saved your circuit topology and channel layout requirements in Power Distribution Requirements. No components, wiring, or PCB layout have been created yet.
Before I can size the fuse, copper, and resistors safely, I need:
Maximum total current and maximum current per channel.
Maximum voltage applied to the green sockets, and whether all eight resistor channels operate continuously together.
Any board-size or connector-spacing constraints.
Thermal concern: At 24 V, each 160 Ω resistor dissipates 3.6 W—28.8 W for all eight. Resistor ratings and spacing must account for that heat.
Building and verifying the schematic and PCB requires Agent mode. Execution stopped because your ACUs ran out.
What is Agent mode?
Agent mode lets Flux build, do deep research, validate designs, and work through complex assignments.
Chat mode is just as smart and has the same engineering knowledge, but it cannot work autonomously.
Only Agent mode consumes your plan's included AI usage (measured in ACUs).