Power Distribution Requirements
Requested circuit
- One 24 V input terminal and one GND terminal.
- One fuse holder in series directly after the 24 V input.
- Eight red 4 mm PCB-mount banana sockets connected in parallel to the fused 24 V bus.
- Eight black 4 mm PCB-mount banana sockets connected in parallel to the GND bus.
- Eight green 4 mm PCB-mount banana sockets. Each green socket connects through its own 160 ohm high-power resistor (R1–R8) to GND. Green sockets are not connected directly to the 24 V bus.
- Arrange eight channels, each containing one red socket, one black socket, one green socket, and its resistor.
- Use mechanically robust through-hole banana sockets.
- Size the main 24 V and GND copper for the total distribution current.
Topology
24 V input → fuse holder → fused 24 V bus → red sockets 1–8.
GND input → GND bus → black sockets 1–8.
Green socket n → Rn (160 ohms) → GND bus, for n = 1–8.
Inputs needed before electrical and mechanical sizing
- Maximum total distribution current and maximum per-channel current; continuous versus intermittent operation.
- Maximum voltage applied to the green sockets and whether all eight resistor channels may be loaded continuously at once.
- Board size or spacing constraints and intended mounting/support of banana sockets.
Preliminary calculation, not a verified component selection
If a green socket is held at 24 V relative to GND, its resistor carries 24/160 = 0.15 A and dissipates 24²/160 = 3.6 W. Eight such resistors dissipate 28.8 W total. Final resistor ratings require voltage limits, thermal derating, spacing, airflow, and ambient temperature. No resistor rating, fuse rating, trace width, or connector part has been selected or verified.
Session state
Only these requirements were recorded. The project has no components or nets. No schematic, PCB layout, part sourcing, or verification has been performed. Execution stopped because the account ran out of ACUs.