Refine this doc
Ask about this doc

Last modified 1mo ago

Via In Pad Repair
Assigned batch — completed
Both violations shared the same simple cause: an unnecessary through-hole via centered on a same-net plated through-hole pad. Deleted only the two Smart Via parents and their generated via children in one batch (one actual fix attempt per violation). No traces were removed, replaced, moved, or resized. No component placement, board outline, stackup, net, or rule was changed; Via In Pad checking remains enabled.

Table


NetPadPad UIDRemoved Smart Via UIDRemoved generated via UIDPosition mm
LAMPE_R (8428585f-bc72-4ea1-b77d-bba997311b53)Red-:Red-2743ba86-926b-42a2-8426-e2c938beb144a09d2bc5-f48f-4cf1-bd1a-63602e995148a09d2bc5-f48f-4cf1-bd1a-63602e995148.throughHole.0-018.0407, 7.5596
Y (5d276eb4-a005-4438-acb6-7684a86960fa)R9:1a4772d24-198f-45cc-bb45-3bc986a162cd__14311bdb-feda-4e42-a32e-c7464e91d071d4f140c0-71ed-4dd6-89be-b7e3f6d048f3d4f140c0-71ed-4dd6-89be-b7e3f6d048f3.throughHole.0-018.3269, 21.9059
Geometry and connectivity evidence
Read-only layout inspection identified Red- as a 2 mm rectangular plated-through pad with 1.2 mm drill, exactly concentric with its via. Its 1 mm Top trace 1cc7c9f2-f2a5-46fe-8a00-802433a3957c from Q1:C reaches the pad copper. Its 0.8 mm Bottom segment 8027891f-f635-48f0-aa98-dcf48e0de4f3 is a roughly 0.066 mm stub entirely inside that pad.
R9:1 is a 1.88 mm round through-hole pad with 1 mm drill. Its via was exactly concentric. Top trace e03cf832-1e1e-43f0-bc50-595ec791336d and Bottom trace b160792e-e2e4-4f4a-bc62-50fe51797529 already terminate at the pad center; the plated pad supplies the layer connection without a separate via. Both pad types and dimensions were read from the existing project layout, not assumed from an external part variant.
Post-edit read-only tree inspection confirms all nine original route segments on LAMPE_R and Y remain unchanged and both Smart Via nodes are absent.
Fresh verification
Checks reviewed at 2026-10-18T18:08:33.307Z:

Table


CheckBeforeAfterSeverity after
Via In Pad20Success
Airwires00Success
Overlapping Copper00Success
Floating Copper00Success
All assigned errors are resolved with no connectivity regression. No blocked or failed item in the assigned batch.
Separate warnings / overall status
An additional Redundant Traces check returned 46 warning groups board-wide; mutation feedback reported one newly introduced warning. These are warnings (possibly unnecessary copper), not shorts or missing connections. Left all traces untouched to honor the narrow routing scope; no board-wide cleanup was attempted. The local Red- Bottom stub 8027891f-f635-48f0-aa98-dcf48e0de4f3 is a concrete optional cleanup candidate: remove only that enclosed stub, then repeat connectivity checks. Do not blindly remove the separately flagged working Q1:C-to-Red- Top trace 1cc7c9f2-f2a5-46fe-8a00-802433a3957c; its physical role was inspected and preserved. Other warning groups require a separate scoped review. Completion of this batch is not a full-board manufacturing-readiness claim.
  • Assigned batch — completed

  • Geometry and connectivity evidence

  • Fresh verification

  • Separate warnings / overall status