Project Idea Starter
flux
Table
| U2 pin | Connected net | Connected components |
|---|---|---|
| 1 — EN | BAT_FUSED | F2 P2, VIN, C15 P1, C17 P1, TP_BAT |
| 2 — SEL | BAT- | Grounded to select the CFG3-programmed output |
| 3 — CFG1 | U2_CFG1 | R14 P1 |
| 4 — CFG2 | U2_CFG2 | R15 P1 |
| 5 — CFG3 | U2_CFG3 | R13 P1 |
| 6 — VOUT | 3V3_SYS | C16 P1 and downstream 3.3 V loads |
| 7 — LX2 | U2_LX2 | L2 P2 |
| 8 — GND | BAT- | Battery return |
| 9 — LX1 | U2_LX1 | L2 P1 |
| 10 — VIN | BAT_FUSED | F2 P2, EN, C15 P1, C17 P1, TP_BAT |
| 11 — EP | BAT- | Exposed thermal/ground pad |
J2 pin 1 / BAT+ → F2 (1 A resettable fuse) → BAT_FUSED → U2 VINBAT-, connected to system GND through the existing R11 0 Ω star link.U2_LX1 → U2 pin 9U2_LX2 → U2 pin 7BAT_FUSEDBAT-BAT_FUSEDBAT-3V3_SYSBAT-U2_CFG3 → BAT-U2_CFG1 → BAT-U2_CFG2 → BAT-3V3_SYS, nominally 3.3 V.