XAL5050 Footprint Check


Read-only task, no mutations. Certify XAL5050-103MEC live footprint against authoritative Coilcraft recommended land pattern. Parent PCB has pads 1.18 x4.34 mm at x +/-1.655 mm (center pitch3.31). query_datasheet returned contradictory/weak drawing evidence saying 3.31 inner edge gap. Need actual manufacturer drawing visual geometry or reliable evidence whether 3.31 is pitch or gap and whether pads certify. Investigate with tools and report concise exact comparison, citations or blocker. Do not modify part.
I’ll inspect the live pad geometry, locate Coilcraft’s official XAL5050 mechanical/land-pattern drawing, and reconcile the dimension-chain meaning before giving a pass/fail certification.
Checking the official Coilcraft drawing and the live footprint geometry in parallel.
Live footprint confirmed: two 1.180 × 4.340 mm pads centered at x = ±1.655 mm, so center pitch is 3.310 mm and copper inner-edge gap is 2.130 mm.
Certification: FAIL — live footprint does not match Coilcraft’s recommended land pattern.
  • Coilcraft pattern: pads 1.18 × 4.70 mm; 3.31 mm is the inner-edge gap, not center pitch.
  • Therefore required center pitch = 3.31 + 1.18 = 4.49 mm, with centers at x = ±2.245 mm and outer span 5.67 mm.
  • Live footprint: pads 1.18 × 4.34 mm, centers x = ±1.655 mm; pitch 3.31 mm, inner gap 2.13 mm, outer span 4.49 mm.
  • Errors: centers are 0.590 mm too far inward per pad; pad length is 0.360 mm undersized.
Authoritative source: Coilcraft XAL50xx manufacturer datasheet, “Recommended Land Pattern.” No modifications made.