Result: conditionally qualified — drilling remains a hard blocker
The active source part is read-only, so I made no mutations and published no new version. Current source version remains HEAD, latest project commit #c6f09816.
Drawing-to-footprint comparison
Authoritative drawing: Bel 0826-1X1T-HS-F, recommended footprint shown from the component side, units inch [mm], .XXX footprint tolerance ±0.004 in.
Table
Feature
Bel drawing
Actual read-back
Assessment
Pins 1–6
2.032 mm pitch, Y=15.24
Exact
Pass
Pins 7–12
2.032 mm pitch, Y=17.78
Exact
Pass
Row separation
2.54 mm
Exact
Pass
Pins 13–16
X=±5.59; Y=6.59/8.13
Exact
Pass
Pins 17–20
Y=20.32; X=±6.096/±3.556
Exact
Pass
Shield S1/S2
X=±8.065, Y=−3.18
Exact
Pass
Locating posts
X=±6.35, Y=0
Exact
Pass
Electrical pads
20
20
Pass
Shield pads
2
2
Pass
Locating holes
2
2
Pass
Pin-1 marking
Rectangular pin 1
Present
Pass
Copper layers
Top and Bottom annular layers
Present
Pass
Body outline
16.38 × 33.02 mm nominal
Footprint outline matches
Pass
Jack/front face
−Y end, approximately Y=−22.1 mm
Matches outline/model orientation
Pass
Maximum height
13.61 mm nominal
Model exists, but package-height read-back unavailable
Conditional
LED polarity
17−/18+ yellow; 19+/20− orange and 19−/20+ green
Terminal mapping preserved
Pass
The footprint also correctly preserves all 22 schematic-terminal mappings.
Hard blocker for carrier J3/J4
Flux read-back exposes pad copper sizes but not the baked drill diameters or plated/NPTH classification. Therefore J3/J4 are not fabrication-qualified yet. Required drawing hole classes are:
Pins 1–16: Ø0.89 mm, +0.13/−0.00 mm
Pins 17–20: Ø1.02 mm, +0.13/−0.00 mm
S1/S2: Ø1.57 mm
Two locating posts: Ø3.25 mm, NPTH
I did not apply or recommend blind overrides because the existing drill values cannot be read back, and overwriting potentially correct drills would not be a proven repair.
Exact local-override procedure
For each placed J3 and J4, inspect its descendant pad UIDs, then create selector-based rulesets with !important:
Pins 1–16: holeSize=0.89mm, padHoleType=STD
Pins 17–20: holeSize=1.02mm, padHoleType=STD
S1/S2: holeSize=1.57mm, padHoleType=STD
Two unnumbered locating holes: holeSize=3.25mm, padHoleType=HOLE
Do not alter positions, pad copper sizes, orientation, or terminal mapping. The exact executable selectors cannot be safely supplied until J3/J4’s actual descendant node UIDs are available.
No proven coordinate, pitch, count, layer, polarity, or orientation defect was found. No source repair was justified, and no version was published.