Check that all reset/enable have an external pull-up or pull-down resistors. Rep...

@copilot Check that all reset/enable have an external pull-up or pull-down resistors. Report action items in an ordered list.
3y
  1. SGP41_EN - This enable pin does not appear to have an external pull-up or pull-down resistor. Please add one accordingly.
  2. IC3 - This reset pin does not seem to have a pull-down resistor, Consider adding one externally.
  3. 1V8_EN - It appears that this pin does not have either a pull-up or pull-down resistor. Check the datasheet of the component it's connected to and add a resistor as needed.
  4. SCD41_EN - Similarly, this enable pin does not seem to have a pull-up or pull-down resistor. Please add an external pull-up or pull-down resistor.
  5. 3V3_EN - This enable pin does not have a pull-up or pull-down resistor. Please add one as needed.
  6. SHT40_EN - This enable pin seems not to be connected to any resistor. Consider adding an external pull-up or pull-down resistor.
For each enable/reset pin without a pull-up or pull-down resistor, verify the requirements based on the specific IC datasheet. Sometimes internal pull-ups/ pull-downs are provided.
3y
Someone is typing...
R5
Resistance
10kΩ
R10
Resistance
Rpg Ω
C1
Capacitance
100nF
C4
Capacitance
1uF
C6
Capacitance
1uF
C2
Capacitance
100nF
R2
Resistance
10kΩ
C7
Capacitance
1uF
C8
Capacitance
1uF
C9
Capacitance
22uF
C3
Capacitance
1uF
R9
Resistance
500 Ω
R3
Resistance
4.7 Ω
R8
Resistance
500 Ω
R4
Resistance
1kΩ
IC2
J4
J5
IC1
Not Recommended for New Designs
Q2
J2
U3
S1
D1
Capacitance
12pF
Q1

ULP Air Quality