Confirmed: four shield pads share number 25, but only one renders—three are missing; I made no edits because renumbering alone could disconnect them from shield terminal EH. The repair needs permission to add three shield terminals and update the symbol; I also filed the defect for Flux team review (details, Contact Support).
May I make those additional shield-terminal and symbol changes?
I’ll add the three shield terminals, give the four shield pads unique numbers, and verify that all four appear. I’ll leave the signal pins, pad geometry, silkscreen, and 3D model unchanged.
All four shield pads now appear in the bottom view, mapped to terminals 25–28. I’m checking the final mapping and confirming that signal pins and geometry stayed unchanged; all four shield terminals will need to connect to the same shield net in designs using this part.
Fixed and verified: all four shield pads now render, with unique terminals EH/25, EH2/26, EH3/27, and EH4/28. Signal pins, pad geometry, silkscreen appearance, and the 3D model remain unchanged; details are in the repair report.
Connect pins 25–28 to the same shield net when using this part—they are not internally tied in Flux; the changes are saved but not published.
EH/25, EH2/26, EH3/27 and EH4/28 are common physical shell. Connect all four to the same shield net in consuming designs; no internal schematic tie is implemented.
27
EH3
Passive
Bottom
EH/25, EH2/26, EH3/27 and EH4/28 are common physical shell. Connect all four to the same shield net in consuming designs; no internal schematic tie is implemented.
28
EH4
Passive
Bottom
EH/25, EH2/26, EH3/27 and EH4/28 are common physical shell. Connect all four to the same shield net in consuming designs; no internal schematic tie is implemented.