I’ll create only the new comparison guide and leave all existing files unchanged. The brief’s “Related in Flux” URLs point to unrelated LED parts, so I’ll use the BME280 guide and AHT20 links supplied earlier in the brief instead.
For aht20 vs bme280, the main difference is pressure sensing: BME280 measures pressure, humidity, and temperature; AHT20 measures humidity and temperature. Pick BME280 when pressure or SPI is required, and AHT20 for a humidity-and-temperature-only I²C design.
Scope: exact bare Bosch BME280 and bare Aosong/ASAIR AHT20, not breakout modules, AHT10, AHT21, or other sensor variants. Electrical operating limits are not absolute-maximum stress ratings. Implementation choices below are labeled as engineering guidance.
Checked the saved guide’s structure, citations, and both datasheet pinouts.
Values left out: matched-condition current/power comparisons, conversion-speed rankings, and full-range maximum accuracy limits. I did not establish sufficiently verified, comparable values for those claims. Prices and stock were excluded as requested.
Pinout risk: the parts are not pin- or footprint-compatible. Replacement requires PCB remapping and new firmware, and AHT20 does not retain pressure sensing. No hardware testing was performed.
For aht20 vs bme280, the main difference is pressure sensing: BME280 measures pressure, humidity, and temperature; AHT20 measures humidity and temperature. Pick BME280 when pressure or SPI is required, and AHT20 for a humidity-and-temperature-only I²C design.
Scope: exact bare Bosch BME280 and bare Aosong/ASAIR AHT20, not breakout modules, AHT10, AHT21, or other sensor variants. Electrical operating limits are not absolute-maximum stress ratings. Implementation choices below are labeled as engineering guidance.
Quick answer
Table
Choose BME280 if...
Choose AHT20 if...
You need barometric pressure as well as humidity and temperature.
You need humidity and temperature without pressure.
Your host design requires SPI.
Your host design uses I²C.
You need a separately supplied digital interface.
One shared sensor/logic supply fits your design.
You want to retain an existing BME280 PCB and driver.
You can redesign the footprint and replace the driver.
These choices follow the measurement, interface, supply, and pinout differences below; neither device is a drop-in replacement for the other.
Electrical comparison
Table
Parameter
BME280
AHT20
What it means for your design
Measured quantities
Pressure, humidity, temperature.
Humidity and temperature.
AHT20 cannot supply the pressure channel of a weather or altitude application.
Recommended operating supply
VDD: 1.71–3.6 V; separate VDDIO: 1.2–3.6 V.
VDD: 2.2–5.5 V, 3.3 V typical; bus pull-ups go to VDD.
A shared regulated 3.3 V supply is within both operating ranges. AHT20's higher supply limit does not make BME280 compatible with that rail.
Digital interface
I²C or three-/four-wire SPI.
I²C.
A BME280 SPI design requires a bus change to use AHT20.
I²C address, seven-bit notation
0x76 with SDO at GND; 0x77 with SDO at VDDIO; tie CSB to VDDIO.
0x38.
Update the driver address; changing only the address is insufficient.
Humidity accuracy, manufacturer definitions
Typically ±3 %RH at 25 °C over 20–80 %RH, including hysteresis.
Typically ±2 %RH; factory-test basis 3.3 V and 25 °C, non-condensing; excludes hysteresis and nonlinearity.
Not an identical error budget. Do not rank total system humidity accuracy from these two typical values alone.
Temperature accuracy at 25 °C
Typically ±0.5 °C.
Typically ±0.3 °C at 3.3 V and 25 °C, non-condensing; excludes hysteresis and nonlinearity.
These are typical point-condition values, not guaranteed errors throughout the operating range. Board heat still needs validation.
Manufacturer datasheets: Bosch BME280 and Aosong AHT20. The accuracy rows preserve each manufacturer's conditions rather than implying a fully matched test method.
Pinout and package differences
The package drawings and pin-description tables were checked before this comparison. The compact pin-order table is a migration reference, not a repeat of the BME280 guide's full connection table.
Table
Bare IC / common package
Pin order by manufacturer pin number
Package-view check
BME280, eight-contact metal-lid LGA; body 2.50 × 2.50 mm, height 1.00 mm maximum in the mechanical table.
Top-view diagram: left column 1, 2, 3; right column 6, 5, 4, each from top to bottom.
The pin order is different. The parts are neither pin-compatible nor footprint-compatible. Do not place AHT20 on a BME280 land pattern; replace the footprint and remap nets from the manufacturer's drawing. A module's connector pin order is separate from its bare IC pinout.
Design differences in a circuit
Supply and logic: BME280 has separate sensor and interface rails. AHT20's SDA/SCL pull-ups must use its VDD, so a split-rail BME280 design may need level translation or a different supply arrangement.
Passives: Bosch recommends two 100 nF capacitors and gives 4.7 kΩ as a normal value for each I²C pull-up, subject to bus load and timing. The cited AHT20 revision specifies a nearby 10 µF VDD-to-GND capacitor and shows 4.7 kΩ pull-ups. Follow the selected revision rather than assuming the decoupling requirements are identical.
Configuration: Remove BME280's CSB/SDO straps when replacing its symbol. AHT20 has neither pin; preserve its NC contacts as unconnected.
Firmware: Replace the BME280 driver, not just its address. In the cited AHT20 revision, wait at least 100 ms after power-on and check calibration status; the measurement command is 0xAC followed by 0x33 and 0x00. Wait more than 80 ms after triggering, then check the busy flag before accepting data.
Worked example: migrating an I²C humidity monitor
Engineering example: assume a regulated 3.3 V host and sensor rail, room-temperature use at 25 °C, and existing SDA/SCL pull-ups of 4.7 kΩ each. Both sensors permit this supply; the resistor value appears in both manufacturers' application guidance, but actual bus rise time and sink-current margins still require checking.
Keep that rail and one effective pair of pull-ups. Replace the BME280 footprint with AHT20, connect VDD/SCL/SDA/GND to their new pins, leave NC contacts open, and provide the AHT20 revision's 10 µF local decoupling. Retain a labeled supply test point as engineering guidance.
Change the seven-bit address from the configured BME280 value to AHT20's 0x38 and install its command/readout driver. For an illustrative AHT20 raw humidity code S_RH = 524288, the manufacturer's equation RH = (S_RH / 2^20) × 100 %RH gives 50 %RH; this is a calculated decoding example, not an accuracy or bench-test result. Remove the pressure output from the application, or redesign around an additional pressure sensor if that function is still required.
PCB and layout differences
Replace the land pattern, paste, and assembly orientation using the appropriate package drawing; the different body dimensions and contact counts prevent footprint reuse.
Reroute power, ground, SDA, and SCL to the new pin numbers and remove obsolete CSB/SDO routing.
Reserve local space for AHT20's specified 10 µF capacitor rather than copying the BME280 decoupling placement unchanged. Engineering guidance: revalidate thermal bias and air access in the final enclosure after moving the sensor.
Can I replace BME280 with AHT20?
Yes, with PCB and firmware changes, but only if pressure measurement is not required. No, it is not a same-footprint replacement.
Replace the symbol and land pattern, and remap every connection using the pin-order table.
Recheck the supply and pull-up voltage, particularly if BME280 used a separate interface rail.
Revise local decoupling to match the cited AHT20 application guidance.
Replace the driver, address, initialization, conversion timing, and data decoding.
Remove pressure-dependent functions or add a separately designed pressure channel.
FAQ
BME280 vs AHT20: which should I use for a weather station?
Choose BME280 if the station must measure barometric pressure alongside humidity and temperature. AHT20 covers humidity and temperature only, so a pressure requirement needs another sensor.
Is AHT20 more accurate than BME280?
The typical accuracy values and their conditions are listed above; they are not a universal ranking. In particular, Bosch's cited humidity tolerance includes hysteresis, while Aosong's stated accuracy excludes hysteresis and nonlinearity, so compare the complete error budget and validate the assembled product.
Can BME280 and AHT20 share an I²C bus?
Their documented seven-bit addresses differ, so the pair does not inherently create an address collision. Use a mutually compatible supply/pull-up arrangement and check the combined bus loading; AHT20 requires its pull-ups to VDD.
Can I keep the BME280 software when switching to AHT20?
No; shared I²C wiring does not imply a compatible sensor protocol. Use AHT20's initialization, trigger, busy-status, and readout sequence rather than changing only the address in the BME280 driver.
AHT20 part page — the comparison-part link supplied for this guide; the bare IC comparison above does not establish module compatibility.
Sources
Bosch Sensortec BME280 datasheet, cover revision 1.24, release February 2024, document BST-BME280-DS001-24. Sections used: electrical characteristics, interfaces, pinout/connection diagrams, and package dimensions. Some page footers retain earlier revision text; the revision here follows the cover.
Aosong/ASAIR Data Sheet AHT20, V1.0, May 2021, manufacturer-hosted edition. Sections used: sensor characteristics and accuracy footnotes, supply/interface requirements, package/pinout, application circuit, and measurement/readout. Do not mix its application and initialization instructions with those of another AHT20 manual revision.
Document check: compared bare ICs, preserved manufacturer test conditions and typical-versus-maximum distinctions, checked both package pinouts, and included no prices or stock claims. This is a documentation comparison, not a hardware or firmware validation.
Quick answer
Electrical comparison
Pinout and package differences
Design differences in a circuit
Worked example: migrating an I²C humidity monitor
PCB and layout differences
Can I replace BME280 with AHT20?
FAQ
BME280 vs AHT20: which should I use for a weather station?
Is AHT20 more accurate than BME280?
Can BME280 and AHT20 share an I²C bus?
Can I keep the BME280 software when switching to AHT20?