Refine this doc
Ask about this doc

Last modified 7mo ago

Project Specification
Overview
Complete MIPI CSI-2 camera daughter board centered on the Sony IMX335LQN-C image sensor. The board accepts 3.3 V input from a 20-pin Hirose DF40C-20DP-0.4V(51) board-to-board connector and generates AVDD 2.9 V, DVDD 1.2 V, and OVDD 1.8 V locally. The sensor outputs a 2-lane MIPI CSI-2 interface plus differential clock, is controlled over I2C at address 0x1A, and uses a 24 MHz external input clock.
Architecture

Diagram


20 pin board connector MIPI ESD array 1 MIPI ESD array 2 IMX335 image sensor I2C reset and enable 24 MHz oscillator 3.3V input 2.9V AVDD regulator 1.2V DVDD regulator 1.8V OVDD regulator
Electrical requirements
  • Sensor: Sony IMX335LQN-C
  • Video interface: 2-lane MIPI CSI-2 with one differential clock pair
  • Control bus: I2C target address 0x1A
  • Input clock: 24 MHz
  • Input supply: 3.3 V
  • Local rails: 2.9 V analog, 1.2 V digital core, 1.8 V I/O
  • MIPI protection: 2 x ST ECMF2-40A100N6 placed at the external connector side
  • Debug access: test points for I2C and key power rails
Mechanical requirements
  • Layout size: 20 mm x 32 mm
  • Stackup: 4 layers
  • Board thickness: 1.0 mm
  • MIPI target impedance: 100 ohm differential
  • Lens opening: 12.5 mm diameter M12 mount hole aligned over the image sensor
Design defaults
  • Use a solid ground plane; do not split analog and digital grounds.
  • Use low-capacitance ESD protection on external high-speed lines and place it close to the connector.
  • Provide local 100 nF decoupling at each sensor supply group plus bulk capacitance per regulator output.
  • Use 1.8 V pull-ups for the sensor control bus unless host-side level requirements later force translation.
Design Summary
Status: Draft / Review / Approved
Manufacturing target: Prototype / EVT / DVT / PVT / Production
Software / firmware: repository link

Scope
Purpose
In scope
Out of scope

System context

Requirements
Functional
Electrical
Mechanical / environmental

Key constraints

Dependencies and risks
Dependencies
Key risks

Validation
Success criteria
Planned checks

Release-facing notes
Expected deliverables
Special release notes

Change notes / open questions
Changes in this revision
Open questions
  • Overview

  • Architecture

  • Electrical requirements

  • Mechanical requirements

  • Design defaults

  • Design Summary

  • Scope

  • System context

  • Requirements

  • Functional

  • Electrical

  • Mechanical / environmental

  • Key constraints

  • Dependencies and risks

  • Validation

  • Release-facing notes

  • Change notes / open questions