Access Reader Design
Table
| Area | Candidate standard or evidence | Current status |
|---|---|---|
| Wi-Fi/BLE radio | Modular approval conditions for ESP32-S3-WROOM-1 | Must verify exact module FCC/CE docs and antenna keepout |
| NFC/LF emissions | EN 300 330 or regional SRD rules | Requires product-level RF/EMC testing |
| EMC immunity/emissions | EN 55032/55035, IEC 61000-4-x | Requires prototype testing |
| ESD | IEC 61000-4-2 on enclosure and external ports | Design protection matrix required |
| Safety | IEC/UL 62368-1 style SELV assessment | PoE isolation boundary must be documented |
| PoE | IEEE 802.3af PD compliance | Class and power budget not final |
| Access control | UL 294 / EN 60839 style considerations if target market requires | Product/regional requirement TBD |
| Environmental | Indoor 0 to 50 C, non-condensing | Outdoor/IP65 not in Rev A scope |
Table
| Item | Status |
|---|---|
| Product description | Drafted in Project Specification |
| Block diagram | Drafted in Project Specification |
| Schematic | Not started |
| PCB layout/Gerbers | Not started |
| BOM with MPNs | Not started |
| RF module datasheets and grants | Required |
| Antenna keepout evidence | Required after layout |
| EMC/RF lab test reports | External lab work required |
| User manual safety warnings | Draft required before pilot |
| Declaration of conformity | Draft after BOM and intended market are frozen |
Table
| Hazard | Source | Effect | Preliminary mitigation |
|---|---|---|---|
| Electric shock or insulation failure | PoE flyback isolation boundary | User/service risk, certification failure | Use certified transformer, creepage/clearance rules, no copper crossing isolation gap |
| Fire/overheat | Undersized 5 V buck, PoE flyback or relay driver | Enclosure heating, device failure | Worst-case power budget, thermal checks at 50 C, current limiting/fuse |
| Door unlock failure unsafe state | MCU reset, relay driver glitch, brownout | Unintended unlock or failure to unlock | Relay drivers default off, brownout reset, watchdog, safe firmware state machine |
| Relay contact degradation | Inductive lock/turnstile load | Welded or failed contacts, EMI reset | Snubber/TVS/MOV footprints and installation guidance for external suppression |
| ESD reset/damage | User-accessible ports and card area | Device crash or permanent damage | TVS/ESD protection on DC, RJ45, RS-485, Wiegand, USB, inputs and enclosure strategy |
| RF read failure | Metal mounting, antenna detuning, EMI from PoE/bucks | Poor user experience or denied access | RF floorplan, tuning network, EVT antenna measurements in enclosure |
| Credential compromise | Physical access to service port/flash | Security breach | Secure boot, flash encryption, production debug lock-down, unique certs |
Status
Applicable Categories
Likely Standards and Evidence
Technical Construction File Draft Checklist
Safety Risk Register
Design Requirements Added From Compliance Review