Part Information Review and Updates
Table
| Field | Current value | Datasheet check | Status |
|---|---|---|---|
| Manufacturer Part Number | XL4016 | Matches datasheet MPN | OK |
| Manufacturer Name | XLSEMI | Matches datasheet manufacturer | OK |
| Description | 8A 180KHz 40V Buck DC to DC Converter | Matches datasheet description | OK |
| Datasheet URL | already set | Present, so no web lookup/update was needed | OK |
| Package or Case Code | TO | Datasheet package is TO220-5L | Mismatch |
| Designator Prefix | PS | Not contradicted by datasheet | OK |
Table
| Parameter | Value |
|---|---|
| Function | Buck DC-DC converter |
| Package | TO220-5L |
| Switching frequency | 180 kHz fixed |
| Recommended input range | 8 V to 36 V |
| Adjustable output range | 1.25 V to 32 V |
| Load capability | 8 A |
| Constant output current capability | 12 A |
| Max efficiency | up to 96% |
| Protection/features | thermal shutdown, current limit, short-circuit protection |
Table
Table
| Area | Issue | Severity |
|---|---|---|
| Package metadata | Project says TO, datasheet says TO220-5L | Medium |
| Pin count | Datasheet also lists the metal tab connected to SW, but the project currently has only 5 terminals | High |
| Pin types | All terminals are still set to Unspecified: GND, FB, SW, VC, VIN | High |
| Pin descriptions | No pin descriptions are populated on the terminals | High |
| Symbol completeness | No dedicated terminal for the exposed/tab connection, even though exposed pads/tabs should be represented when listed in the datasheet | High |
Table
Welcome 👋
Flux accelerates your PCB design with AI.
Create your account to start using this component and bring your ideas to life.