Please fix this, based from this flag issue: SQJQ4...


Please fix this, based from this flag issue:
SQJQ480E-T1GE3 footprint models the two upper drain extensions as separate unbound mount pads (6 and 9) touching/overlapping terminal D, causing two overlapping-copper shorts. Vishay Doc 67477 shows one contiguous D land.
I’ll check Vishay’s drain-land geometry, correct the two unbound extensions, and verify that the overlapping-copper shorts are resolved.
Thinking for 20 hrs 24 mins...
Thought for 5 sec
Referenced guidance.
Thought for 5 sec
Created 2 tasks.
1/2 Correct the source drain footprint using Vishay Doc 67477.

Correct the source drain footprint using Vishay Doc 67477.

Verify drain geometry and connectivity, and file the part-quality ticket.

Thought for 12 sec
Awaiting 1 task

G
S_2
D
S_1
S_3
Name
Pin #
Type
Section
Pin Group
Orientation
Order
Sub-symbol
Current
S_1
1
Passive
1.8A
S_2
2
Passive
1.8A
S_3
3
Passive
1.8A
G
4
Input
D
5
Passive
1.8A

SQJQ480E-T1_GE3