LMR33630 Pin 3 Fix


Please fix this, based from this flag issue:
The library symbol marks U3:NC as a no-connect, causing ERC error when tied to SW. TI LMR33630-Q1 VQFN datasheet says pin 3 NC has no internal connection but should/must be connected to SW on the PCB to simplify CBOOT-to-SW routing.
This requires editing and publishing the reusable part, which needs Agent mode. I’ll keep physical terminal/pad 3 named NC per TI, remove its no-connect classification, assign a connectable passive/power-compatible electrical type, preserve all footprint geometry/mapping, verify it can join the SW net without ERC, and publish a new version.Switch to Agent mode so I can apply, verify, and publish the corrected reusable part definition.
It's now on agent mode.
I’m inspecting terminal 3 and pin 12 first, then I’ll correct only the ERC semantics, verify the footprint mapping is unchanged, and publish the updated part.
Corrected and saved as reusable part version #dd384ee1.
  • Physical pin/pad 3 renamed from NC to SW (SW::PIN3 internally for uniqueness).
  • Pin type changed from Unspecified to Power In, matching pin 12 SW.
  • Added TI guidance: internally unconnected, but PCB pad 3 should connect to SW for CBOOT routing.
  • Confirmed no no-connect marker remains.
  • Verified pin number 3, pad UID, pad position/size, RNX0012B footprint asset, and all 12-pad geometry remain unchanged.
  • Part terminal and ERC checks report no matching errors.
Validate downstream usage
Audit all terminals
Inspect version diff

Name
Pin #
Type
Part Type
Pin Description
Pin Group
PGND
1
Power In
Terminal
VIN
2
Power In
Terminal
SW::PIN3
3
Power In
Terminal
No internal connection; connect PCB pad 3 to SW as recommended by TI for simplified CBOOT-to-SW routing.
SW
BST
4
Unspecified
Terminal
VCC
5
Power In
Terminal
AGND
6
Power In
Terminal
FB
7
Input
Terminal
PG
8
Open Collector
Terminal
EN
9
Input
Terminal
VIN
10
Power In
Terminal
PGND
11
Power In
Terminal
SW
12
Power In
Terminal

LMR33630-Q1