Battery Converter Design
Table
| # | Functional cluster | Directly attributable | Notes |
|---|---|---|---|
| 1 | Potentiostat analog drive/current sense/reference/AGND | 3 | U_DAC/AGND and AGND–DGND link contacts |
| 2 | Fault/current-limit/load-detect/shutdown | 12 | All are around U_FAULT_LATCH |
| 3 | USB-C and power regulation | 9 | J_USB shell plus U_LDO_D/U_LDO_A |
| 4 | Arduino/OLED/encoder/digital control | 8 | ADC alert, FTDI, Arduino/OLED grounds, encoder mount |
| 5 | SMB connectors/INT-EXT selector/output connectors | 1 | Directly identified J_SMB_RE shell-pad contact |
| 6 | Same-net trace-pad/via artifacts or unclassified UID-only findings | 243 | Route/via/pad findings lacking enough net metadata |
| Total | 276 | Exact current DRC total |
route UID → net mapping.U_DAC:~LDAC~02b33325…__b7589d9c… ↔ Trace 05f949ac…R_AGND_DGND:P17a2ef6c8…__dff57d78… ↔ Trace 6d968da8…R_AGND_DGND:P17a2ef6c8…__dff57d78… ↔ Trace f3f05564…~LDAC~ contact is known to be an AGND same-net pad-entry artifact. The two star-link resistor endpoint contacts also look like intentional route-to-pad entries under the global keepout rule. No current different-net analog short is proven from these three pairs alone.238d (six pairs), 271b (seven), 017c (ten), and 7f6d (four) should not be dismissed merely because many other findings are artifacts; their nets are absent from the DRC payload.U_FAULT_LATCH:~Q2 ↔ Trace 971c1df2… — 1~Q1 ↔ Traces 390c3a33…, a62859dc… — 2RESET1 ↔ Traces 390c3a33…, 3f29e212…, 4f4ccedc…, a62859dc… — 4SET1 ↔ Traces 3f29e212…, 4f4ccedc…, c7b8f58b…, e2abafba…, ecb87307… — 5~Q1/~Q2 contacts are the highest-risk representatives. Those latch outputs have previously appeared as logically unused/no-connect outputs; copper touching them should be treated as a credible real risk until net identity is verified.RESET1/SET1 pairs form repeated pad/branch networks and are much more characteristic of same-net trace–pad/trace–trace keepout artifacts.U_LDO_D:NC31161b42…__30f3e345… ↔ Trace 3e0f0717…U_LDO_D:EN31161b42…__9a6ce0c6… ↔ Trace 091187a2…U_LDO_A:OUT9c206145…__5ad4e767… ↔ Trace 122a5ed1…U_LDO_A:GND9c206145…__8c60cffa… ↔ Trace 1e9a82ee…J_USB:S1 shell/mount pad8bbcaffd…mounts.21c2dc92… ↔:
00c9b93a…534bbe72…6cbf7b65…cb954fac…df47c909…U_LDO_D:NC ↔ Trace 3e0f. A routed copper object touching an NC pad is not an ordinary intended junction.J_USB:S1 contacts are credible shell/mount-pad risks, because S1 is a footprint shell pad rather than one of the explicitly named GND_A/GND_B signal pads. They may be intentional shell grounding, but the current logical data does not prove that.U_ADC:ALERT/RDY ↔ Trace 1fc1dbad… — 1J_FTDI:Pin_6 ↔ Trace a7e275a8… — 1J_FTDI:Pin_1 ↔ Trace 343116ad… — 1OLED1:GND ↔ Trace 4ea4338f… — 1U_ARD:GND pads ↔ Trace 90e09d93…, plus one ↔ Trace a99c449f… — 3ENC1:P$6 mechanical mount ↔ Trace ee2aa7d7… — 1U_ADC:ALERT/RDY ↔ Trace 1fc1 is a confirmed same-net ADC_ALERT pad-entry artifact.ee2a is the highest-risk digital representative because the mount is not an ordinary signal pad.J_SMB_RE:2 shell pad0d88c73c…__78f5c63d… ↔ Trace a3b89a5d…a3b89a5d is on SMB_SHIELD_STAR; otherwise it is a real center/signal-to-shell-area clearance problem.P1/P2 reports almost certainly belong to SMB, selector, or output connectors, but their owning component is not encoded in the DRC check name and they therefore remain in cluster 6.017c — 10 reported neighbors271b — 7238d — 61554 — 533b1 — 583fc — 57f6d — 44f4c — 46da8 — 4U_LDO_D:NC ↔ Trace 3e0fU_FAULT_LATCH:~Q2 ↔ Trace 971cU_FAULT_LATCH:~Q1 ↔ Traces 390c, a628J_USB:S1 ↔ five tracesJ_SMB_RE:2 ↔ Trace a3b8ENC1:P$6 mount ↔ Trace ee2a017c, 271b, 238d, and 83fcU_DAC:~LDAC~ ↔ Trace 05f9 — same-net AGNDU_ADC:ALERT/RDY ↔ Trace 1fc1 — same-net ADC_ALERTRESET1 and SET1 route contactsWE_DRV, WE_INT, I_SENSE_POS/NEG, I_SENSE, and references.U_LDO_D:NC and unused U_FAULT_LATCH:~Q1/~Q2.017c, 271b, 238d, and 83fc.Waiting for input
U_ARD:D7 schematic terminal association to ADC_ALERT.WE_DRV vias after duplicate consolidation.U_ARD (Arduino Pro Mini), part UID bda0f4f7-1320-fd1b-f928-113e441a9220.U_ARD:D7.ADC_ALERT, connecting U_ARD:D7 and U_ADC:ALERT/RDY.471c48e5-b5c3-427e-af75-a02ea5cd46c0.D7.471c48e5-b5c3-427e-af75-a02ea5cd46c0__396c0555-648f-9396-1a76-f87437825709.ADC_ALERT.U_ARD:D7 was disconnected and reconnected to the existing ADC_ALERT net. This refreshed the project-level terminal/net association without changing routing.Destination pad U_ARD.D7 not found on board. This appears to be an underlying Arduino Pro Mini library-part terminal-resolution issue rather than a missing pad. An internal part-quality report was filed. No routing test was made afterward because the requested stop point was before routing.Table
| # | DRC object pair | Classification | Basis / required later action |
|---|---|---|---|
| 1 | U_DAC:~LDAC~ pad vs Trace 05f9 | Same-net pad-entry overlap / likely false positive | ~LDAC~ is intentionally tied to AGND; the trace appears to terminate at the pad. Confirm trace net is AGND before suppressing or accepting. |
| 2 | Element 041602a8 mounting feature vs Trace 5867 | Mechanical/footprint conflict | The object is a footprint mounting feature. Copper crossing a mount/hole region must be checked against the actual module footprint and rerouted if the mount is drilled or plated. |
| 3 | Element 041602a8 mounting feature vs Trace e812 | Mechanical/footprint conflict | Same mounting-feature issue as #2; do not accept for fabrication without confirming the mount geometry. |
| 4 | Trace 0bbc vs SMB shell pad b261b350...__5fe63358 | Real cross-net short | 0bbc is in the WE_DRV source/Kelvin region; the SMB shell pad belongs to SMB_SHIELD_STAR. Reroute WE_DRV away from the shell pad. |
| 5 | Trace 0bbc vs R_SENSE:P2 | Real cross-net short | R_SENSE:P2 is WE_INT, while the source-side branch is WE_DRV. This violates the required separation across the sense resistor. |
| 6 | Trace 0bbc vs Trace ecea | Real/unsafe trace crossing pending exact trace-net readback | It occurs in the same source/sense area as #4–5. Treat as a real short until both trace nets are proven identical. |
| 7 | Trace 1fc1 vs U_ADC:ALERT/RDY pad | Same-net pad-entry overlap, but geometrically poor | Both are ADC_ALERT. It is electrically intended, but the vertical trace consumes the AIN0-side escape corridor and should be rerouted later. |
| 8 | U_OUT:~SHDN pad vs Trace b0b5 | Real cross-net short | b0b5 is WE_DRV; ~SHDN is OPA_SHDN. |
| 9 | U_OUT:V+ pad vs Trace b0b5 | Real cross-net short | V+ is 3V3_A; b0b5 is WE_DRV. |
| 10 | Trace 9508 vs Trace b0b5 | Real cross-net short | Local U_OUT fanout crosses the WE_DRV source trace; reroute after identifying 9508's exact endpoint net. |
| 11 | Trace 9868 vs Trace b0b5 | Real cross-net short | Same U_OUT fanout conflict as #10. |
Table
| Via UID | Exact world position | Layers / size | Current assessment |
|---|---|---|---|
2373f7b6-0201-4671-a640-fdc9abd2484a | (-60.8129 mm, -149.0676 mm) | Through, Top-to-Bottom; 0.6 mm pad / 0.3 mm drill | Authoritative deletion readback identified the pair as WE_DRV. DRC currently reports the retained via as floating, so it touches no effective trace/pad and is not electrically useful yet. |
604c14a6-d9cd-425d-86a1-4e4c696c2a7d | (-58.6129 mm, -148.2676 mm) | Through, Top-to-Bottom; 0.6 mm pad / 0.3 mm drill | Same: net-tagged as WE_DRV by mutation readback, but currently floating in DRC. |
U_OUT-to-R_SENSE:P1 Kelvin source path because both are reported floating.U_OUT–R_SENSE source copper was not modified during this verification.WE_DRV or delete them after a verified net/geometry check. Do not leave floating copper in the manufacturing package.D7 logical and PCB-pad net associations agree after refresh.WE_DRV vias are consolidated; two retained vias remain floating.Scope and stop point
U_ARD D7 terminal mapping
Current verified state
Applied repair
Remaining library issue
Classification of 11 overlapping-copper DRC items
Classification summary
Retained WE_DRV vias
Kelvin impact
PCBWay fabrication baseline
Current stop state