Schematic Drafting Resume Notes
Scope
User requests readable functional blocks, local wires and inter-block labels, with NO electrical changes. 91 components, 54 nets, 14 existing functional groups. Continuation approved.
State at ACU stop, 26 October 2026
Incomplete. Reuse persisted drafting executor t7. Its latest completion notification arrived at cutoff, but the final report was NOT retrieved; retrieve it before editing because its last focused pass may have repaired some findings below.
Last retrieved report
All 91 components grouped; R7 rotated 270 degrees below Q2 gate. Power top, sensing/MCU/radio/driver middle, interfaces below. 40 local wires drawn and 9 long wires converted to labels in earlier pass. Interfaces still grid-arranged; MOSFETs far from U3. Later pass moved 27 designator labels, repacked U4/U5/U3 blocks and aligned ground glyphs but worsened some wires.
Last retrieved counts (potentially stale): 19 wire-through-symbol errors, 21 wire crossings, 49 visible-connectivity warnings, 35 crowding warnings, 85 label collisions, about 25 vertical labels, sheet fill 0.23 versus 0.45 target.
Preservation evidence
Builder compared schematic to pre-drafting history
#e26c50b5: nets section unchanged, including names, identities and pin memberships; all 91 components retain values. Only drawing positions/rotations/wires changed. PCB not compared. Must reconfirm after final edits. No independent review yet.
Nine pre-existing ERC errors reported on U4 (undriven PVIN/AVIN/EN/SS-TR and conflicting SW outputs). Builder attributed these to pin typing; not independently verified. Do NOT modify electrical connections under this task.
Latest focused pass instructions (retrieve outcome)
Do not repack or repeat tidy. Read flat-view endpoints; manually reroute each wire-through-symbol segment with waypoints. If impossible, remove only visual wire to restore labels without changing net membership. Examples: 5V_SERVO through C14, DRV_CPL/DRV_VREF through C3, GND through C4/R2/TP3. Then move text/decorations for vertical labels and collisions without dragging wires. Use schematic images where checks lag.
Resume plan
- Retrieve newest t7 report and current sheet/check state.
- Complete drawing cleanup block by block, starting wire-through-symbol errors, then label collisions/crowding and local wiring. Preserve all electrical connections and values.
- Inspect filtered blocks and full sheet visually; run checks and document pre-existing electrical findings separately.
- Run one fresh independent read-only review after drafting is complete; none has happened yet.
- Recompare net/pin membership against #e26c50b5 and update notes.
Side conversation
Answered questions about DGX Spark: Flux assistant is hosted, no supported local installation; open-weight models do not automatically gain Flux editing access. Flux backend memory/model size unavailable to me. No research performed for those conversational answers.