Placement qualification resume handoff
Session status — 2026-10-27
User approved footprint/header qualification and local placement repairs, followed by remaining routing and current/thermal validation. The existing Kelvin integration work was resumed with that scoped brief. A completion notification arrived, but its final report could not be retrieved before ACUs ran out. No specific PCB change or check result from this pass has been reconciled. Inspect current live state and recover the completed report before editing again.
Recover first
Existing executor reference: 802f980f-19ab-4c52-8a2d-bbbef2368490, name Kelvin Shunt Integration. Reuse its persisted work; do not duplicate writers or repeat failed research.
Last independently verified baseline from previous session: 169 airwires; zero redundant traces; six dedicated Kelvin sense nets connected. Scoped checks: 12 undriven-input ERC flags, three regulator placement errors, R18/J6 body overlap 13.07 mm² and U4/J6 clearance-only warning. These are historical, not verified current results.
Approved repair brief
- Qualify CSS4J-4026K-2L00F shunt lands from manufacturer drawing/authoritative EDA or verified footprint. Prior live force lands approx 2.007 × 4.699 mm, overall span 10.06 mm; recommended drawing reported 10.60 mm span, 5.50 mm inner separation and 5.60 mm force-land height. Establish datums, topology and mapping before edits; do not infer numerical assignments from incomplete evidence.
- Qualify FTSH-103-01-L-DV programming header mechanical body and footprint registration. Distinguish misaligned 3D model from genuine component collision. Do not shift manufactured pads to match an incorrect model.
- User approved necessary LOCAL header/shunt/neighbour placement repair. Preserve 25.4 × 50.8 mm outline, fixed edge wire interfaces, receiver J5 behind servo pads, top connectors/wire pads and two-sided MOSFET/passive placement policy.
- Correct regulator C1/C4 orientation/input-bank arrangement from fresh actual geometry. Last checker suggestions: C1 rotation 0°, C4 90°, place C1 HF cap at end of input bank rather than between C2/C3. Validate hints rather than applying blindly.
- Preserve valid copper and all six isolated Kelvin nets; restore any affected routes. Remove only identified redundant/invalidated copper.
- Do not suppress 12 ERC flags without proving root cause. Prior MCU pin-type metadata was unavailable.
- Reconcile geometry and fresh overlap/bounds/keepout/power-stage/ERC/airwire checks BEFORE the next major routing wave.
Remaining phases
Complete qualified force/source-reference paths and remaining signal routing, followed by current-capacity and thermal assessment for 30 A continuous/50 A burst on 2S–3S. Burst duration, cooling and operating conditions must be explicit for final rating claims. No generic signal-width routes for power current; no manufacturing or safe-to-power claim from connectivity alone.
Historical 1.90 mm bottom-pad coordinate discrepancy did not reproduce in latest read-only inspection; do not assume a persistent platform blocker or compensate with guessed offsets. If it recurs, stop affected edits and capture exact evidence.
Existing files: read-only-resume-review-2026-10-24 short ID 6o; routing-coordinate-support-report short ID x7.
Programming-box/transponder projects remain on hold. Board remains unready for power or manufacturing pending verified completion.