Latched 16.5 V Undervoltage Protection


Created a project doc

Power Supply Requirements

View Document

Power Supply Requirements User request
Design a circuit with Mini560 PRO 12 V specifications and undervoltage shutdown at 16.5 V. Once undervoltage trips, output must stay off even if input recovers. Restart requires disconnecting and reconnecting the DC source. This requires a latched fault, not ordinary automatically resetting hysteresis alone.
Attached product image
The supplied Mini560/Mini560 PRO product-information image lists the PRO 12 V variant as 12 V output, 14–32 V input, and less than 4 A output. Cooling is indicated for sustained currents above roughly 3 A; the translated wording is ambiguous. General PRO specifications list 500 kHz switching, 95% maximum efficiency, non-isolated synchronous buck conversion, and 33 × 18 × 5.4 mm size. These are vendor image claim...
Your circuit needs latched undervoltage protection, not just hysteresis: below 16.5 V, it must shut down and stay off even if the supply voltage recovers. Disconnecting and reconnecting the source should reset it, provided the input voltage is high enough.
The attached image lists the Mini560 PRO’s 12 V version as 14–32 V input and less than 4 A output, with cooling indicated for sustained loads above about 3 A. These are vendor claims, not verified performance.
I saved these requirements in Power Supply Requirements. No schematic or layout has been built yet. Before selecting components, I need to clarify:
  • Are you adding protection to a purchased Mini560 PRO module, or building a complete equivalent converter?
  • What DC source will power it, and what is its maximum voltage?
  • What continuous and peak current does your 12 V load need?
Component research, schematic creation, and verification require Agent mode. Execution stopped because your ACUs ran out.
What is Agent mode?
Agent mode lets Flux build, do deep research, validate designs, and work through complex assignments.
Chat mode is just as smart and has the same engineering knowledge, but it cannot work autonomously.
Only Agent mode consumes your plan's included AI usage (measured in ACUs).
Continue in Agent Mode

Waiting for input

No schematic yet

Talk to Flux to get started.

Power Supply Requirements
User request
Design a circuit with Mini560 PRO 12 V specifications and undervoltage shutdown at 16.5 V. Once undervoltage trips, output must stay off even if input recovers. Restart requires disconnecting and reconnecting the DC source. This requires a latched fault, not ordinary automatically resetting hysteresis alone.
Attached product image
The supplied Mini560/Mini560 PRO product-information image lists the PRO 12 V variant as 12 V output, 14–32 V input, and less than 4 A output. Cooling is indicated for sustained currents above roughly 3 A; the translated wording is ambiguous. General PRO specifications list 500 kHz switching, 95% maximum efficiency, non-isolated synchronous buck conversion, and 33 × 18 × 5.4 mm size. These are vendor image claims, not independently verified ratings.
Preliminary direction — not implemented
Use an input-voltage monitor with noise hysteresis, a fault latch reset by genuine input power removal, and an appropriately rated power disconnect or verified converter-enable interface. The monitor/latch must stay powered upstream of the switched load so load disconnection or input rebound cannot clear the fault. Startup below the valid input threshold must not enable the output. Component selection, reset discharge timing, threshold tolerances, and transient behavior remain undesigned and unverified.
Open requirements
  • Is this a protection circuit around a purchased Mini560 PRO module, or an integrated buck design matching its ratings?
  • DC source type, nominal and maximum voltage including transients.
  • Required continuous and peak 12 V load current.
  • Required restart threshold/hysteresis and minimum disconnect time, if constrained.
Work state
No schematic components or nets have been created. No parts research, simulation, or layout has been performed. Execution stopped because the user's ACUs ran out.
  • User request

  • Attached product image

  • Preliminary direction — not implemented

  • Open requirements

  • Work state