I’ll recover the saved repair state, finish the electrical safety fixes, then complete placement and routing where the design is qualified. I’ll retain the existing ESP32-S3 boards and SPI motor interfaces, and keep any unresolved motor-power limits explicit.
I repaired the ADC bus pull-ups, sourced the remaining isolation support parts, and added the first motor’s interlock circuitry. The second interlock and signal-contention checks are still incomplete, so I’m finishing those before moving the new hardware onto the PCB.
In carrier-work: delete the existing H1 and H2 headers. Add H1 (2x18), H2 (2x18) and H3 (2x12), omitting pin 1 on each for keying. Rewire all existing header nets onto the matching pins of the new headers using the pin map: H1/H2 pins 1-6 power, 7-10 lighting, 11-14 high-side, 15-18 triggers, 19-24 CAN (two channels), 25-26 I2C, 27-28 spares, 29 nRST, 30-36 GND. Commit "headers".
Thought for 55 sec
flux
22 days ago
I’ll treat this as a separate header change in carrier-work, leaving the current safety review undisturbed. Before deleting headers, I need the exact net-to-pin assignments: the ranges don’t distinguish individual power rails, signals, or the two CAN channels, and H3 has no mapping yet.
Completed the widened-scope repair of the U1 via-in-pad defect and the displaced Bank A signal routes. The assigned copper-repair batch is complete; this is not a whole-project electrical or fabrication release.
Table
Assigned item
Status
Evidence
Remove the forbidden OE via overlap at U1 4~OE
Completed
Original via removed; new off-pad OE escape at (-46.2, 25.2) mm; Via In Pad review has no Error/Warning.
Restore MCU_A_LED_OE_N
Completed
All four U1 OE pins, Q9:C and R5:P1 connected; zero airwires.
Restore LED1_BUF
Completed
U1:1Y to R1:P1 connected through two off-pad vias and a 0.15 mm Mid-Layer 2 corridor.
Restore LED3_DATA
Completed
R3:P2, R77:P1 and J7:1 connected; the checkpoint-proven connector branch was restored.
Repair local ground islands created during rerouting
Completed
Added a C5 ground stitch at (-49.85, 28.92) mm with a Top tie; added a Bottom bridge from R77 ground to R76 ground. No ground airwires remain.
Re-protect finished routing
Completed
Protected=true applied to all 68 routing roots of the three Bank A signal nets and all seven new ground-repair roots, 75 roots total. Read-back confirms all three signal vias are protected.
Preserve schematic, placement and interfaces
Completed
Six Bank A/Bank B net memberships match checkpoint #031cb452 exactly. Positions, rotations and layers of 15 scoped components and counterparts match that checkpoint exactly. No components were moved or replaced.
Preserve stackup, manufacturing limits and original power widths
Completed
No stackup, clearance, via-in-pad permission, manufacturing-profile or original power-routing edits were made. All authored traces are 0.15 mm; only the specified signals and seven new local GND nodes changed.
No assigned copper-repair item remains failed or blocked.
Final read-only verification
The routing-state inspection reports 0 airwires and 0 redundant traces. Fresh native checks at 2026-10-08T22:58:16.342Z reported no Error or Warning for:
Via In Pad
Airwires
Overlapping Copper and Overlapping Traces
Keepout
Protected Intrusions
Under-connected Vias
Dangling and Redundant Traces
Invalid Layer
Stackup Validation
These results establish completion of the checked local routing repair, not clearance of every possible project check or certification of the automotive application.
Preserved logical connections
Table
Net
Terminals, unchanged from #031cb452
MCU_A_LED_OE_N
R5:P1, Q9:C, U1:1OE, U1:2OE, U1:3OE, U1:4OE
LED1_BUF
R1:P1, U1:1Y
LED3_DATA
R3:P2, J7:1, R77:P1
MCU_B_LED_OE_N
R36:P1, Q18:C, U3:1OE, U3:2OE, U3:3OE, U3:4OE
MCU_B_LED1_BUF
R32:P1, U3:1Y
MCU_B_LED3_DATA
R34:P2, J26:1, R81:P1
Verified unchanged placement for U1/U3, Q9/Q18, R5/R36, R77/R81, R1/R32, R3/R34, J7/J26 and C5. Bank B copper was not modified by this repair. The existing bank arrangement and connector access were preserved. The starting placement is not an exact geometric mirror, and newly exact bank-to-bank copper mirroring was not attempted or claimed.
Mounting-hole objects, BOM exclusion, MPN metadata and other component properties were not edited by this repair. Concurrent metadata changes were not rolled back.
Implementation notes
OE was rerouted after freeing only the three scoped Bank A signal nets. A deterministic off-pad transition avoided repeated pad-level pathfinder failures.
LED1 uses off-pad vias at (-45.85, 20.0) and (-50.0069, 30.0081) mm. Its Mid-Layer 2 centerline is (-45.85,20.0) → (-45.85,22.2) → (-50.6,26.95) → (-50.6,29.415) → (-50.0069,30.0081), all at 0.15 mm width. The westward corridor leaves clearance for the C5 ground stitch.
The LED3 connector branch was recovered from read-only checkpoint geometry; its buffer-to-bias branch was rerouted around the new OE tie.
Separate cleanup commits removed temporarily dangling LED1 segments during staged work. The final LED1 route was therefore authored as one complete batch; the final routing-state read has no dangling cleanup candidates.
No whole-board autorouter pass was needed. No clearance relaxation, smaller power trace, component movement or via-in-pad allowance was used.
Remaining work outside this batch
Fresh read-only ERC/MPN checks at 2026-10-08T23:02:20.109Z still report 30 Undriven Nets errors on U5/U6 and two Unspecified Pin Type warnings on D5/D11. They were not remediated because they are outside this routing assignment. The queried manufacture-part-number review returned no Error/Warning at that time.
Unattempted outside scope: global ERC remediation, exact new copper mirroring of both banks, full-board rerouting, EM/SI simulation, manufacturing export and fabrication release. Existing automotive power and socket-geometry validation requirements remain in force.